Assessing model mismatch and model selection in a Bayesian uncertainty quantification analysis of a fluid-dynamics model of pulmonary blood circulation

This study uses Bayesian inference to quantify the uncertainty of model parameters and haemodynamic predictions in a one-dimensional pulmonary circulation model based on an integration of mouse haemodynamic and micro-computed tomography imaging data. We emphasize an often neglected, though important source of uncertainty: in the mathematical model form due to the discrepancy between the model and the reality, and in the measurements due to the wrong noise model (jointly called ‘model mismatch’). We demonstrate that minimizing the mean squared error between the measured and the predicted data (the conventional method) in the presence of model mismatch leads to biased and overly confident parameter estimates and haemodynamic predictions. We show that our proposed method allowing for model mismatch, which we represent with Gaussian processes, corrects the bias. Additionally, we compare a linear and a nonlinear wall model, as well as models with different vessel stiffness relations. We use formal model selection analysis based on the Watanabe Akaike information criterion to select the model that best predicts the pulmonary haemodynamics. Results show that the nonlinear pressure–area relationship with stiffness dependent on the unstressed radius predicts best the data measured in a control mouse.

[1]  With Invariant Submanifolds,et al.  Systems of Conservation Laws , 2009 .

[2]  Jenný Brynjarsdóttir,et al.  Learning about physical parameters: the importance of model discrepancy , 2014 .

[3]  M. Olufsen,et al.  Numerical Simulation and Experimental Validation of Blood Flow in Arteries with Structured-Tree Outflow Conditions , 2000, Annals of Biomedical Engineering.

[4]  Maria Pia Saccomani,et al.  The Union between Structural and Practical Identifiability Makes Strength in Reducing Oncological Model Complexity: A Case Study , 2018, Complex..

[5]  Dirk Husmeier,et al.  Influence of image segmentation on one-dimensional fluid dynamics predictions in the mouse pulmonary arteries , 2019, Journal of the Royal Society Interface.

[6]  W. O'Dell,et al.  Considerations for numerical modeling of the pulmonary circulation--a review with a focus on pulmonary hypertension. , 2013, Journal of biomechanical engineering.

[7]  Dirk Husmeier,et al.  MCMC with delayed acceptance using a surrogate model with an application to cardiovascular fluid dynamics , 2019, Proceedings of the International Conference on Statistics: Theory and Applications.

[8]  Leif R Hellevik,et al.  Roadmap for cardiovascular circulation model , 2016, The Journal of physiology.

[9]  Robin Shandas,et al.  Impact of pulmonary vascular stiffness and vasodilator treatment in pediatric pulmonary hypertension: 21 patient-specific fluid-structure interaction studies , 2012, Comput. Methods Programs Biomed..

[10]  Zoubin Ghahramani,et al.  Sparse Gaussian Processes using Pseudo-inputs , 2005, NIPS.

[11]  Alison L Marsden,et al.  Evolution of hemodynamic forces in the pulmonary tree with progressively worsening pulmonary arterial hypertension in pediatric patients , 2019, Biomechanics and Modeling in Mechanobiology.

[12]  Giancarlo Pennati,et al.  Patient‐specific parameter estimation in single‐ventricle lumped circulation models under uncertainty , 2017, International journal for numerical methods in biomedical engineering.

[13]  Sumio Watanabe,et al.  Asymptotic Equivalence of Bayes Cross Validation and Widely Applicable Information Criterion in Singular Learning Theory , 2010, J. Mach. Learn. Res..

[14]  Jeffrey Mueller,et al.  Patient-specific computational modeling of blood flow in the pulmonary arterial circulation , 2015, Comput. Methods Programs Biomed..

[15]  P. J. Green,et al.  Density Estimation for Statistics and Data Analysis , 1987 .

[16]  Christopher K. I. Williams,et al.  Gaussian Processes for Machine Learning (Adaptive Computation and Machine Learning) , 2005 .

[17]  Aki Vehtari,et al.  Bayesian Modeling with Gaussian Processes using the GPstuff Toolbox , 2012, 1206.5754.

[18]  Feng Liang,et al.  Quantifying model structural error: Efficient Bayesian calibration of a regional groundwater flow model using surrogates and a data‐driven error model , 2017 .

[19]  Lawrence L. Wald,et al.  Physiological noise and signal-to-noise ratio in fMRI with multi-channel array coils , 2011, NeuroImage.

[20]  Pras Pathmanathan,et al.  Considering discrepancy when calibrating a mechanistic electrophysiology model , 2020, Philosophical Transactions of the Royal Society A.

[21]  Mette S Olufsen,et al.  Numerical simulation of blood flow and pressure drop in the pulmonary arterial and venous circulation , 2014, Biomechanics and modeling in mechanobiology.

[22]  Sam Coveney,et al.  Fitting two human atrial cell models to experimental data using Bayesian history matching. , 2018, Progress in biophysics and molecular biology.

[23]  Taha Sochi,et al.  Heterogeneous mechanics of the mouse pulmonary arterial network , 2016, Biomechanics and modeling in mechanobiology.

[24]  Daniela Valdez-Jasso,et al.  Modeling and Identification of Vascular Biomechanical Properties in Large Arteries. , 2010 .

[25]  Pras Pathmanathan,et al.  Uncertainty and variability in models of the cardiac action potential: Can we build trustworthy models? , 2016, Journal of molecular and cellular cardiology.

[26]  Subin Solomen,et al.  Biomechanics of Circulation , 2018 .

[27]  A. Lungu,et al.  MRI model-based non-invasive differential diagnosis in pulmonary hypertension. , 2014, Journal of biomechanics.

[28]  Richard D. Deveaux,et al.  Applied Smoothing Techniques for Data Analysis , 1999, Technometrics.

[29]  A. Pettitt,et al.  Marginal likelihood estimation via power posteriors , 2008 .

[30]  U. Windberger,et al.  Whole Blood Viscosity, Plasma Viscosity and Erythrocyte Aggregation in Nine Mammalian Species: Reference Values and Comparison of Data , 2003, Experimental physiology.

[31]  Robert Molthen,et al.  Effects of acute Rho kinase inhibition on chronic hypoxia-induced changes in proximal and distal pulmonary arterial structure and function. , 2011, Journal of applied physiology.

[32]  Naomi C Chesler,et al.  Persistent vascular collagen accumulation alters hemodynamic recovery from chronic hypoxia. , 2012, Journal of biomechanics.

[33]  Dirk Husmeier,et al.  MCMC methods for inference in a mathematical model of pulmonary circulation , 2018, 1801.07742.

[34]  Gary R. Mirams,et al.  Calibration of ionic and cellular cardiac electrophysiology models , 2020, Wiley interdisciplinary reviews. Systems biology and medicine.

[35]  David A. Steinman,et al.  An image-based modeling framework for patient-specific computational hemodynamics , 2008, Medical & Biological Engineering & Computing.

[36]  Andrew Gelman,et al.  General methods for monitoring convergence of iterative simulations , 1998 .

[37]  Richard H Clayton,et al.  Bayesian sensitivity analysis of a 1D vascular model with Gaussian process emulators , 2017, International journal for numerical methods in biomedical engineering.

[38]  Christopher A Dawson,et al.  Flow and pressure distributions in vascular networks consisting of distensible vessels. , 2003, American journal of physiology. Heart and circulatory physiology.

[39]  Naomi C. Chesler,et al.  Changes in Large Pulmonary Arterial Viscoelasticity in Chronic Pulmonary Hypertension , 2013, PloS one.

[40]  Dirk Husmeier,et al.  A computational study of pulmonary hemodynamics in healthy and hypoxic mice , 2017, 1712.01699.

[41]  Rachel B. Clipp,et al.  An evaluation of dynamic outlet boundary conditions in a 1D fluid dynamics model. , 2011, Mathematical biosciences and engineering : MBE.

[42]  J P Mynard,et al.  A simple, versatile valve model for use in lumped parameter and one‐dimensional cardiovascular models , 2012, International journal for numerical methods in biomedical engineering.

[43]  Mary I Townsley,et al.  Structure and composition of pulmonary arteries, capillaries, and veins. , 2012, Comprehensive Physiology.

[44]  Hervé Delingette,et al.  Efficient probabilistic model personalization integrating uncertainty on data and parameters: Application to eikonal-diffusion models in cardiac electrophysiology. , 2011, Progress in biophysics and molecular biology.

[45]  John Geweke,et al.  Evaluating the accuracy of sampling-based approaches to the calculation of posterior moments , 1991 .

[46]  Mette S Olufsen,et al.  Sensitivity analysis and uncertainty quantification of 1‐D models of pulmonary hemodynamics in mice under control and hypertensive conditions , 2019, International journal for numerical methods in biomedical engineering.

[47]  John K Kruschke,et al.  Bayesian data analysis. , 2010, Wiley interdisciplinary reviews. Cognitive science.

[48]  Gary R. Mirams,et al.  Uncertainty and variability in computational and mathematical models of cardiac physiology , 2016, The Journal of physiology.

[49]  I E Vignon-Clementel,et al.  Uncertainty quantification in virtual surgery hemodynamics predictions for single ventricle palliation , 2016, International journal for numerical methods in biomedical engineering.

[50]  Yu Shen,et al.  Identification of the Fraction of Indolent Tumors and Associated Overdiagnosis in Breast Cancer Screening Trials , 2018, American journal of epidemiology.

[51]  A. O'Hagan,et al.  Bayesian calibration of computer models , 2001 .

[52]  S. Chib,et al.  Marginal Likelihood From the Metropolis–Hastings Output , 2001 .

[53]  R. Tuder,et al.  Pulmonary vascular remodeling in pulmonary hypertension , 2016, Cell and Tissue Research.

[54]  Vinzenz Gregor Eck,et al.  A guide to uncertainty quantification and sensitivity analysis for cardiovascular applications , 2016, International journal for numerical methods in biomedical engineering.