Wearable lower limb haptic feedback device for retraining Foot Progression Angle and Step Width.

Technological developments in the last decade have enabled the integration of sensors and actuators into wearable devices for gait interventions to slow the progression of knee osteoarthritis. Wearable haptic gait retraining is one area which has seen promising results for informing modifications of gait parameters for reducing knee adduction moments (KAM) during walking. Two gait parameters which can be easily adjusted to influence KAM include foot progression angle (FPA) and step width (SW). The purpose of this study was to: (1) determine whether a custom haptic ankle bracelet using binary vibrotactile and tactile apparent movement feedback could retrain ten healthy subjects to walk with a modified FPA and SW within a short training session with 80% accuracy; and (2) whether there was a difference between the number of steps required to complete the retraining task based on the two feedback schemes being tested. Retraining multiple gait parameters using a single device was a novel aspect of this work and we found that nine out of ten subjects were able to retrain their gait using the ankle bracelet in both feedback schemes to within 2° and 39mm of target FPA and SW respectively. We also found no difference in the number steps required for completion between the two schemes (p>0.05). Future research will investigate the device performance with patients with knee osteoarthritis and the effective change in KAM by modifying a combination of FPA and SW.

[1]  Jeffrey T. Fairbrother,et al.  Effects of increased step width on frontal plane knee biomechanics in healthy older adults during stair descent. , 2014, The Knee.

[2]  Mark R. Cutkosky,et al.  Novel Foot Progression Angle Algorithm Estimation via Foot-Worn, Magneto-Inertial Sensing , 2016, IEEE Transactions on Biomedical Engineering.

[3]  Benjamin J Fregly,et al.  Evaluation of a patient-specific cost function to predict the influence of foot path on the knee adduction torque during gait , 2008, Computer methods in biomechanics and biomedical engineering.

[4]  Scott L Delp,et al.  Six‐week gait retraining program reduces knee adduction moment, reduces pain, and improves function for individuals with medial compartment knee osteoarthritis , 2013, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  N. Basaglia,et al.  Biofeedback treatment of genu-recurvatum using an electrogoniometric device with an acoustic signal. One-year follow-up. , 1989, Scandinavian journal of rehabilitation medicine.

[6]  Iain A. Anderson,et al.  Lower Extremity Lateral Skin Stretch Perception for Haptic Feedback , 2016, IEEE Transactions on Haptics.

[7]  Max R. Paquette,et al.  Greater Step Widths Reduce Internal Knee Abduction Moments in Medial Compartment Knee Osteoarthritis Patients During Stair Ascent. , 2015, Journal of applied biomechanics.

[8]  H. E. Burtt Tactual illusions of movement , 1917 .

[9]  Trevor Hastie,et al.  Risk factors for progressive cartilage loss in the knee: a longitudinal magnetic resonance imaging study in forty-three patients. , 2002, Arthritis and rheumatism.

[10]  Najia Shakoor,et al.  Reduced lower extremity vibratory perception in osteoarthritis of the knee. , 2008, Arthritis and rheumatism.

[11]  Julien Favre,et al.  General scheme to reduce the knee adduction moment by modifying a combination of gait variables , 2016, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[12]  Donna Mergler,et al.  Measurement precision of a portable instrument to assess vibrotactile perception threshold , 2004, European Journal of Applied Physiology and Occupational Physiology.

[13]  M. Cutkosky,et al.  Toe-in gait reduces the first peak knee adduction moment in patients with medial compartment knee osteoarthritis. , 2013, Journal of biomechanics.

[14]  T. Andriacchi,et al.  Gait modification via verbal instruction and an active feedback system to reduce peak knee adduction moment. , 2010, Journal of biomechanical engineering.

[15]  Mark R Cutkosky,et al.  Training multi-parameter gaits to reduce the knee adduction moment with data-driven models and haptic feedback. , 2011, Journal of biomechanics.

[16]  Thomas R Jenkyn,et al.  Test-retest reliability of the peak knee adduction moment during walking in patients with medial compartment knee osteoarthritis. , 2007, Arthritis and rheumatism.

[17]  Mark R. Cutkosky,et al.  Informing haptic feedback design for gait retraining , 2011, 2011 IEEE World Haptics Conference.

[18]  J. Allum,et al.  Effects of biofeedback on trunk sway during dual tasking in the healthy young and elderly. , 2009, Gait & posture.

[19]  Scott L Delp,et al.  Quantified self and human movement: a review on the clinical impact of wearable sensing and feedback for gait analysis and intervention. , 2014, Gait & posture.

[20]  B. Fregly,et al.  Correlation between the knee adduction torque and medial contact force for a variety of gait patterns , 2007, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[21]  F. A. Geldard,et al.  The Cutaneous "Rabbit": A Perceptual Illusion , 1972, Science.

[22]  Clare E. Milner,et al.  Real-Time Kinematic, Temporospatial, and Kinetic Biofeedback During Gait Retraining in Patients: A Systematic Review , 2010, Physical Therapy.

[23]  Peter B. Shull,et al.  Tactile Apparent Movement as a Modality for Lower Limb Haptic Feedback , 2016, EuroHaptics.

[24]  T. Besier,et al.  Real-time knee adduction moment feedback for gait retraining through visual and tactile displays. , 2011, Journal of biomechanical engineering.

[25]  Clare E Milner,et al.  Does increasing step width alter knee biomechanics in medial compartment knee osteoarthritis patients during stair descent? , 2014, The Knee.

[26]  J. Allum,et al.  Directional effects of biofeedback on trunk sway during gait tasks in healthy young subjects. , 2009, Gait & posture.

[27]  Jeffrey A. Reinbolt,et al.  Design of patient-specific gait modifications for knee osteoarthritis rehabilitation , 2007, IEEE Transactions on Biomedical Engineering.

[28]  R. Koheil,et al.  Joint position biofeedback facilitation of physical therapy in gait training. , 1980, American journal of physical medicine.

[29]  Lars Arendt-Nielsen,et al.  Association Between Altered Somatosensation, Pain, and Knee Stability in Patients With Severe Knee Osteoarthrosis , 2012, The Clinical journal of pain.

[30]  Thomas R Jenkyn,et al.  Toe-out gait in patients with knee osteoarthritis partially transforms external knee adduction moment into flexion moment during early stance phase of gait: a tri-planar kinetic mechanism. , 2008, Journal of biomechanics.

[31]  T. M. Owings,et al.  Variability of step kinematics in young and older adults. , 2004, Gait & posture.

[32]  A. B. Drought,et al.  WALKING PATTERNS OF NORMAL MEN. , 1964, The Journal of bone and joint surgery. American volume.