On the Reliability of Chronically Implanted Thin-Film Electrodes in Human Arm Nerves for Neuroprosthetic Applications

Direct stimulation of peripheral nerves can successfully provide sensory feedback to amputees while using hand prostheses. Recent clinical studies have addressed this important limitation of current prostheses solutions using different implantable electrode concepts. Longevity of the electrodes is key to success. We have improved the long-term stability of the polyimide-based transverse intrafascicular multichannel electrode (TIME) that showed promising performance in clinical trials by integration of silicon carbide adhesion layers. The TIMEs were implanted in the median and ulnar nerves of three trans-radial amputees for up to six months. Here, we present the characterization of the electrical properties of the thin-film metallization as well as material status post explantationem for the first time. The TIMEs showed reliable performance in terms of eliciting sensation and stayed within the electrochemical safe limits maintaining a good working range with respect to amplitude modulation. After termination of the trials and explantation of the probes, no signs of corrosion or morphological change to the thin-film metallization was observed by means of electrochemical and optical analysis. Damage to the metallization was assigned exclusively to mechanical impacts during explantation and handling. The results indicate that thin-film metallization on polymer substrates is applicable in permanent implant system.

[1]  O. Witte,et al.  Sensory feedback prosthesis reduces phantom limb pain: Proof of a principle , 2012, Neuroscience Letters.

[2]  S. Cogan Neural stimulation and recording electrodes. , 2008, Annual review of biomedical engineering.

[3]  Silvestro Micera,et al.  Biomimetic Intraneural Sensory Feedback Enhances Sensation Naturalness, Tactile Sensitivity, and Manual Dexterity in a Bidirectional Prosthesis , 2018, Neuron.

[4]  Elaine Biddiss,et al.  Consumer design priorities for upper limb prosthetics , 2007, Disability and rehabilitation. Assistive technology.

[5]  A Cutrone,et al.  Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes. , 2017, Biomaterials.

[6]  T. Stieglitz,et al.  The influence of hot-steam sterilization on hydrated sputtered iridium oxide films , 2013, 2013 6th International IEEE/EMBS Conference on Neural Engineering (NER).

[7]  T. Stieglitz,et al.  A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve. , 2010, Biosensors & bioelectronics.

[8]  Thomas Stieglitz,et al.  “Microflex”—A New Assembling Technique for Interconnects , 2000 .

[9]  Thomas Stieglitz,et al.  Paradigms for restoration of somatosensory feedback via stimulation of the peripheral nervous system , 2017, Clinical Neurophysiology.

[10]  Thomas Stieglitz,et al.  Should patients with brain implants undergo MRI? , 2018, Journal of neural engineering.

[11]  C. Azevedo-Coste,et al.  Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles , 2011, Journal of neural engineering.

[12]  D. Durand,et al.  Functionally selective peripheral nerve stimulation with a flat interface nerve electrode , 2002, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[13]  J. Donoghue,et al.  Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates , 2013, Journal of neural engineering.

[14]  G. E. Loeb,et al.  Cuff electrodes for chronic stimulation and recording of peripheral nerve activity , 1996, Journal of Neuroscience Methods.

[15]  T. Stieglitz,et al.  Comparative Analysis of Transverse Intrafascicular Multichannel Electrode (TIME), Longitudinal Intrafascicular Electrode (LIFE) and Multipolar Cuff Electrode for the Selective Stimulation of Nerve Fascicles , 2011 .

[16]  Silvestro Micera,et al.  Multisensory bionic limb to achieve prosthesis embodiment and reduce distorted phantom limb perceptions , 2018, Journal of Neurology, Neurosurgery, and Psychiatry.

[17]  K. Horch,et al.  Effects of short-term training on sensory and motor function in severed nerves of long-term human amputees. , 2005, Journal of neurophysiology.

[18]  D. Durand,et al.  Chronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode , 2003, Annals of Biomedical Engineering.

[19]  Hambrecht Ft Visual prostheses based on direct interfaces with the visual system. , 1995 .

[20]  S.F. Cogan,et al.  Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  Silvestro Micera,et al.  Phantom somatosensory evoked potentials following selective intraneural electrical stimulation in two amputees , 2018, Clinical Neurophysiology.

[22]  Maurits Ortmanns,et al.  A 232-channel retinal vision prosthesis with a miniaturized hermetic package , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  Dustin J. Tyler,et al.  Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees , 2013, 2013 6th International IEEE/EMBS Conference on Neural Engineering (NER).

[24]  W. Jensen,et al.  A transverse intrafascicular multichannel electrode (TIME) to treat phantom limb pain — Towards human clinical trials , 2012, 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob).

[25]  D. Hutchinson,et al.  A histological analysis of human median and ulnar nerves following implantation of Utah slanted electrode arrays. , 2016, Biomaterials.

[26]  M. Keith,et al.  A neural interface provides long-term stable natural touch perception , 2014, Science Translational Medicine.

[27]  Hans Dietl,et al.  User demands for sensory feedback in upper extremity prostheses , 2012, 2012 IEEE International Symposium on Medical Measurements and Applications Proceedings.

[28]  A Mazzoni,et al.  Comparison of linear frequency and amplitude modulation for intraneural sensory feedback in bidirectional hand prostheses , 2018, Scientific Reports.

[29]  P. Rossini,et al.  Intraneural stimulation elicits discrimination of textural features by artificial fingertip in intact and amputee humans , 2016, eLife.

[30]  P. Rossini,et al.  Stability of Thin-Film Metallization in Flexible Stimulation Electrodes: Analysis and Improvement of in vivo Performance , 2019, bioRxiv.

[31]  Dustin J Tyler,et al.  Neural interfaces for somatosensory feedback: bringing life to a prosthesis. , 2015, Current opinion in neurology.

[32]  P. Alam ‘W’ , 2021, Composites Engineering.

[33]  T. Stieglitz,et al.  Return of the cadaver , 2017, Medicine.

[34]  C. Murray,et al.  An interpretative phenomenological analysis of the embodiment of artificial limbs , 2004, Disability and rehabilitation.

[35]  Thomas Stieglitz,et al.  Thin films and microelectrode arrays for neuroprosthetics , 2012 .

[36]  Stanisa Raspopovic,et al.  Framework for the Development of Neuroprostheses: From Basic Understanding by Sciatic and Median Nerves Models to Bionic Legs and Hands , 2017, Proceedings of the IEEE.

[37]  Dustin J Tyler,et al.  Artificial tactile and proprioceptive feedback improves performance and confidence on object identification tasks , 2018, PloS one.

[38]  David J. Warren,et al.  Using multiple high-count electrode arrays in human median and ulnar nerves to restore sensorimotor function after previous transradial amputation of the hand , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[39]  Silvestro Micera,et al.  Six‐Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback , 2018, Annals of neurology.

[40]  K. Horch,et al.  Object Discrimination With an Artificial Hand Using Electrical Stimulation of Peripheral Tactile and Proprioceptive Pathways With Intrafascicular Electrodes , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[41]  Winnie Jensen,et al.  Stimulation Selectivity of the “Thin-Film Longitudinal Intrafascicular Electrode” (tfLIFE) and the “Transverse Intrafascicular Multi-Channel Electrode” (TIME) in the Large Nerve Animal Model , 2014, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[42]  E. Biddiss,et al.  Upper limb prosthesis use and abandonment: A survey of the last 25 years , 2007, Prosthetics and orthotics international.

[43]  C. Murray,et al.  Being like everybody else: the personal meanings of being a prosthesis user , 2009, Disability and rehabilitation.

[44]  G A Clark,et al.  Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves , 2016, Journal of neural engineering.

[45]  Silvestro Micera,et al.  A closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback , 2018, Science Robotics.

[46]  Silvestro Micera,et al.  Intraneural sensory feedback restores grip force control and motor coordination while using a prosthetic hand , 2019, Journal of neural engineering.

[47]  Thomas Stieglitz,et al.  Improved polyimide thin-film electrodes for neural implants , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[48]  Thomas Stieglitz,et al.  Biocompatibility of Chronically Implanted Transverse Intrafascicular Multichannel Electrode (TIME) in the Rat Sciatic Nerve , 2011, IEEE Transactions on Biomedical Engineering.

[49]  Luca Citi,et al.  Restoring Natural Sensory Feedback in Real-Time Bidirectional Hand Prostheses , 2014, Science Translational Medicine.

[50]  P. Rossini,et al.  Double nerve intraneural interface implant on a human amputee for robotic hand control , 2010, Clinical Neurophysiology.

[51]  Toru Shimizu,et al.  [Explanation of JIS T 62570 Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment]. , 2018, Nihon Hoshasen Gijutsu Gakkai zasshi.

[52]  F T Hambrecht Visual prostheses based on direct interfaces with the visual system. , 1995, Bailliere's clinical neurology.

[53]  Daniel Tan,et al.  Sensory feedback by peripheral nerve stimulation improves task performance in individuals with upper limb loss using a myoelectric prosthesis , 2016, Journal of neural engineering.

[54]  P. Alam ‘T’ , 2021, Composites Engineering: An A–Z Guide.

[55]  J. Mortimer,et al.  A spiral nerve cuff electrode for peripheral nerve stimulation , 1988, IEEE Transactions on Biomedical Engineering.

[56]  Cathrine Widehammar,et al.  The influence of environment: Experiences of users of myoelectric arm prosthesis—a qualitative study , 2017, Prosthetics and orthotics international.

[57]  Winnie Jensen,et al.  Subchronic stimulation performance of transverse intrafascicular multichannel electrodes in the median nerve of the Göttingen minipig. , 2015, Artificial organs.

[58]  Max Ortiz-Catalan,et al.  An osseointegrated human-machine gateway for long-term sensory feedback and motor control of artificial limbs , 2014, Science Translational Medicine.

[59]  S. Ferrari,et al.  Author contributions , 2021 .