Two-Phase Cooling Method Using the R134a Refrigerant to Cool Power Electronic Devices

This paper presents a two-phase cooling method using the R134a refrigerant to dissipate the heat energy (loss) generated by power electronics (PEs), such as those associated with rectifiers, converters, and inverters for a specific application in hybrid-electric vehicles. The cooling method involves submerging PE devices in an R134a bath, which limits the junction temperature of PE devices while conserving weight and volume of the heat sink without sacrificing equipment reliability. First, experimental tests that included an extended soak for more than 850 days were performed on a submerged insulated gate bipolar transistor (IGBT) and gate-controller card to study dielectric characteristics, deterioration effects, and heat-flux capabilities of R134a. Results from these tests illustrate that R134a has high dielectric characteristics and no deterioration of electrical components. Second, experimental tests that included a simultaneous operation with a mock automotive air-conditioner (A/C) system were performed on the same IGBT and gate-controller card. Data extrapolation from these tests determined that a typical automotive A/C system has more than sufficient cooling capacity to cool a typical 30-kW traction inverter. Last, a discussion and simulation of active cooling of the IGBT junction layer with the R134a refrigerant is given. This technique will drastically increase the forward current ratings and reliability of the PE device

[1]  P.H. Desai,et al.  Evaluation of freon modules for power electronics designed for a locomotive traction drive , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[2]  Tore Undeland,et al.  Power Electronics: Converters, Applications and Design , 1989 .

[3]  Issam Mudawar,et al.  Direct-immersion cooling for high power electronic chips , 1992, [1992 Proceedings] Intersociety Conference on Thermal Phenomena in Electronic Systems.

[4]  M. Lallemand,et al.  Modelling of the two-phase cooling of a power semiconductor and its associated evaporators , 1992, [1992 Proceedings] Eighth Annual IEEE Semiconductor Thermal Measurement and Management Symposium.

[5]  H. Kristiansen,et al.  A study on the evaporation heat transfer in the cooling of high power electronics , 1994, Proceedings of 1994 IEEE/CHMT 10th Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM).

[6]  C. Tantolin,et al.  Experimental study of immersion cooling for power components , 1994 .

[7]  G. N. Dulnev,et al.  Evaporation cooling of high power electronic devices , 1996 .

[8]  J. Flannery,et al.  Characterisation of cooling curves for power device die attach using a transient cooling curve measurement , 2000, 2000 IEEE 31st Annual Power Electronics Specialists Conference. Conference Proceedings (Cat. No.00CH37018).

[9]  Patrick E. Phelan,et al.  Current and future miniature refrigeration cooling technologies for high power microelectronics , 2002 .

[10]  Daniel J. Faulkner,et al.  Practical design of a 1000 W/cm/sup 2/ cooling system [high power electronics] , 2003, Ninteenth Annual IEEE Semiconductor Thermal Measurement and Management Symposium, 2003..

[11]  R. L. Webb,et al.  Heat rejection limits of air cooled plane fin heat sinks for computer cooling , 2003 .

[12]  M. Behnia,et al.  Cooling problems and thermal issues in high power electronics - a multi faceted design approach , 2004, 5th International Conference on Thermal and Mechanical Simulation and Experiments in Microelectronics and Microsystems, 2004. EuroSimE 2004. Proceedings of the.

[13]  C.W. Ayers,et al.  Fundamentals of a floating loop concept based on R134a refrigerant cooling of high heat flux electronics , 2006, Twenty-Second Annual IEEE Semiconductor Thermal Measurement And Management Symposium.

[14]  R. H. Staunton,et al.  Evaluation of 2004 Toyota Prius Hybrid Electric Drive System , 2004 .