Method for suppressing the mirror image in Fourier-domain optical coherence tomography.

A method, novel to our knowledge, for effective mirror image suppression in Fourier-domain optical coherence tomography based on a phase shift between neighboring A-mode scans is demonstrated. By realizing that the phase shifts of the real and mirror images are mutually reversed and assuming that the real image intensities of the two successive A-mode scans are the same, we can solve a set of two coupled equations to obtain the real image signals. The images based on the scanning of a high-resolution spectral-domain optical coherence tomography system are processed to show effective mirror image suppression results. Compared with a similar method of broad application, our approach has the advantages of shorter process time and higher flexibility in selecting the concerned image portions for processing.

[1]  Zhongping Chen,et al.  Full range polarization-sensitive Fourier domain optical coherence tomography. , 2004, Optics express.

[2]  Theo Lasser,et al.  Heterodyne Fourier domain optical coherence tomography for full range probing with high axial resolution. , 2006, Optics express.

[3]  Kevin Hsu,et al.  Dual detection full range frequency domain optical coherence tomography. , 2010, Optics letters.

[4]  Ruikang K. Wang In vivo full range complex Fourier domain optical coherence tomography , 2007 .

[5]  W. Drexler,et al.  Dispersion encoded full range frequency domain optical coherence tomography. , 2009, Optics express.

[6]  Joseph A Izatt,et al.  High-speed complex conjugate resolved retinal spectral domain optical coherence tomography using sinusoidal phase modulation. , 2007, Optics letters.

[7]  Changhuei Yang,et al.  Instantaneous quadrature low coherence interferometry with 3 x 3 fiber optic couplers , 2003, Conference on Lasers and Electro-Optics, 2003. CLEO '03..

[8]  J. Izatt,et al.  Complete complex conjugate resolved heterodyne swept-source optical coherence tomography using a dispersive optical delay line , 2011, Biomedical optics express.

[9]  D. Kane,et al.  Resolving the complex conjugate ambiguity in Fourier-domain OCT by harmonic lock-in detection of the spectral interferogram. , 2006, Optics letters.

[10]  A. Fercher,et al.  Phase-shifting algorithm to achieve high-speed long-depth-range probing by frequency-domain optical coherence tomography. , 2003, Optics letters.

[11]  Zhongping Chen,et al.  Removal of a mirror image and enhancement of the signal-to-noise ratio in Fourier-domain optical coherence tomography using an electro-optic phase modulator. , 2005, Optics letters.

[12]  S. Yun,et al.  Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting. , 2004, Optics express.

[13]  Shuichi Makita,et al.  Parabolic BM-scan technique for full range Doppler spectral domain optical coherence tomography. , 2010, Optics express.

[14]  T. Yatagai,et al.  Simultaneous B-M-mode scanning method for real-time full-range Fourier domain optical coherence tomography. , 2006, Applied optics.

[15]  Michael Pircher,et al.  Sample motion-insensitive, full-range, complex, spectral-domain optical-coherence tomography. , 2010, Optics letters.

[16]  Michael Pircher,et al.  Full range complex spectral domain optical coherence tomography without additional phase shifters. , 2007, Optics express.

[17]  Maciej Wojtkowski,et al.  Complex spectral interferometry OCT , 1998, European Conference on Biomedical Optics.

[18]  Sébastien Vergnole,et al.  Artifact removal in Fourier-domain optical coherence tomography with a piezoelectric fiber stretcher. , 2008, Optics letters.