Shaking table test and numerical analysis of an asymmetrical twin‐tower super high‐rise building connected with long‐span steel truss

[1]  Xilin Lu,et al.  Shaking table model tests on a complex high‐rise building with two towers of different height connected by trusses , 2009 .

[2]  Jinkoo Kim,et al.  Seismic performance of structures connected by viscoelastic dampers , 2006 .

[3]  Harry G. Harris,et al.  Structural Modeling and Experimental Techniques, Second Edition , 1999 .

[4]  Wensheng Lu,et al.  Shaking table model test on Shanghai World Financial Center Tower , 2007 .

[5]  Xilin Lu,et al.  Shaking table model test and numerical analysis of a supertall building with high‐level transfer storey , 2012 .

[6]  Qing-jun Chen,et al.  Dynamic response characteristics of super high-rise buildings subjected to long-period ground motions , 2013 .

[7]  Xilin Lu,et al.  Shaking table test and numerical analysis of a high‐rise building with steel reinforce concrete column and reinforce concrete core tube , 2015 .

[8]  Ali Ghanbari,et al.  Estimation of elevated tanks natural period considering fluid- structure- soil interaction by using new approaches , 2017 .

[9]  Bin Zhao,et al.  Shaking table test of a four‐tower high‐rise connected with an isolated sky corridor , 2018 .

[10]  Xilin Lu,et al.  Shaking table test and numerical simulation of an RC frame‐core tube structure for earthquake‐induced collapse , 2016 .

[11]  Faramarz Khoshnoudian,et al.  Effect of vertical component of an earthquake on steel frames considering soil-structure interaction , 2016 .

[12]  Yao Cui,et al.  Seismic performance assessment of low-rise precast wall panel structure with bolt connections , 2019, Engineering Structures.

[13]  Qiusheng Li,et al.  Seismic analysis of the world’s tallest building , 2009 .

[14]  Anil K. Chopra,et al.  A modal pushover analysis procedure for estimating seismic demands for buildings , 2002 .

[15]  R. S. Jangid,et al.  Dynamic response of identical adjacent structures connected by viscous damper , 2014 .

[17]  Hideki Kimura,et al.  Base‐isolated super high‐rise RC building composed of three connected towers with vibration control systems , 2011 .

[18]  N. Null Seismic Evaluation and Retrofit of Existing Buildings , 2014 .

[19]  Ying Zhou,et al.  Shake table testing of a multi-tower connected hybrid structure , 2009 .

[20]  Gongkang Fu,et al.  Shake table model testing and its application , 2008 .

[21]  Bita Mansoury,et al.  Detail design, building and commissioning of tall building structural models for experimental shaking table tests , 2016 .