Impedance measurement for improved power quality-Part 1: the measurement technique
暂无分享,去创建一个
[1] W. C. Beattie,et al. Measurement of harmonic impedance from analysis of transients generated by capacitors , 1995 .
[2] Leszek S. Czarnecki,et al. On-line measurement of equivalent parameters for harmonic frequencies of a power distribution system and load , 1996 .
[3] S.B. Tennakoon,et al. The resonance damping effect associated with linear shunt loads and single-phase converters , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).
[4] J. P. Rhode,et al. Line impedance measurement: a nondisruptive wideband technique , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.
[5] R. Yacamini. Power system harmonics. Part 1. Harmonic sources , 1994 .
[6] Shoji Nishimura,et al. Advanced technology to identify harmonics characteristics and results of measuring , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).
[7] Z. Staroszczyk. Accuracy problems in on-line one-phase distribution/load system identification task , 1996, Proceedings of IEEE International Symposium on Industrial Electronics.
[8] John E. Dennis,et al. Numerical methods for unconstrained optimization and nonlinear equations , 1983, Prentice Hall series in computational mathematics.
[9] Truong Q. Nguyen,et al. Wavelets and filter banks , 1996 .
[10] Z. Staroszczyk,et al. Time-dependent power systems impedance-interpretation and measuring problems , 1999, IMTC/99. Proceedings of the 16th IEEE Instrumentation and Measurement Technology Conference (Cat. No.99CH36309).
[11] S.M. Kay,et al. Spectrum analysis—A modern perspective , 1981, Proceedings of the IEEE.
[12] D.W.P. Thomas,et al. Impedance measurement for improved power quality-Part 2: a new technique for stand-alone active shunt filter control , 2004, IEEE Transactions on Power Delivery.
[13] Mark Sumner,et al. A technique for power supply harmonic impedance estimation using a controlled voltage disturbance , 2002 .
[14] W. Xu,et al. Harmonic impedance measurement using three-phase transients , 1998 .
[15] Fang Zheng Peng,et al. Application issues of active power filters , 1998 .
[16] M. Baran,et al. Instrumentation for measurement of line impedance , 1994, Proceedings of 1994 IEEE Applied Power Electronics Conference and Exposition - ASPEC'94.
[17] Yao Xiao,et al. Harmonic impedance measurement using voltage and current increments from disturbing loads , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).