Impedance measurement for improved power quality-Part 1: the measurement technique

This paper introduces an improved power system impedance measurement technique. The technique injects a short duration current spike into the supply, and derives the impedance from the measured current and voltage. The method is shown to work extremely well under most conditions, by experimental evaluation using a 45-kVA laboratory prototype. Degradation is observed when a voltage-source-type power-electronic load is connected directly to the measurement equipment. An alternative signal processing strategy, based upon the Prony method is proposed to improve the estimation under these conditions. This method also reduces the overall transient data capture time, thus allowing a faster, online calculation of the impedance.

[1]  W. C. Beattie,et al.  Measurement of harmonic impedance from analysis of transients generated by capacitors , 1995 .

[2]  Leszek S. Czarnecki,et al.  On-line measurement of equivalent parameters for harmonic frequencies of a power distribution system and load , 1996 .

[3]  S.B. Tennakoon,et al.  The resonance damping effect associated with linear shunt loads and single-phase converters , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[4]  J. P. Rhode,et al.  Line impedance measurement: a nondisruptive wideband technique , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[5]  R. Yacamini Power system harmonics. Part 1. Harmonic sources , 1994 .

[6]  Shoji Nishimura,et al.  Advanced technology to identify harmonics characteristics and results of measuring , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[7]  Z. Staroszczyk Accuracy problems in on-line one-phase distribution/load system identification task , 1996, Proceedings of IEEE International Symposium on Industrial Electronics.

[8]  John E. Dennis,et al.  Numerical methods for unconstrained optimization and nonlinear equations , 1983, Prentice Hall series in computational mathematics.

[9]  Truong Q. Nguyen,et al.  Wavelets and filter banks , 1996 .

[10]  Z. Staroszczyk,et al.  Time-dependent power systems impedance-interpretation and measuring problems , 1999, IMTC/99. Proceedings of the 16th IEEE Instrumentation and Measurement Technology Conference (Cat. No.99CH36309).

[11]  S.M. Kay,et al.  Spectrum analysis—A modern perspective , 1981, Proceedings of the IEEE.

[12]  D.W.P. Thomas,et al.  Impedance measurement for improved power quality-Part 2: a new technique for stand-alone active shunt filter control , 2004, IEEE Transactions on Power Delivery.

[13]  Mark Sumner,et al.  A technique for power supply harmonic impedance estimation using a controlled voltage disturbance , 2002 .

[14]  W. Xu,et al.  Harmonic impedance measurement using three-phase transients , 1998 .

[15]  Fang Zheng Peng,et al.  Application issues of active power filters , 1998 .

[16]  M. Baran,et al.  Instrumentation for measurement of line impedance , 1994, Proceedings of 1994 IEEE Applied Power Electronics Conference and Exposition - ASPEC'94.

[17]  Yao Xiao,et al.  Harmonic impedance measurement using voltage and current increments from disturbing loads , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).