Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

PURPOSE To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (± SD). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS Dimensional changes compared to reference values varied between -74.01 and 32.57 µm (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth.

[1]  W. Barnes Impression materials. , 1946, Hospital Corps quarterly.

[2]  R. J. Schnell,et al.  Dimensional stability of rubber base impressions and certain other factors affecting accuracy. , 1958, Journal of the American Dental Association.

[3]  H. Wilson,et al.  Elastomeric impression materials. A method of measuring dimensional stability , 1975, British Dental Journal.

[4]  W. Eames,et al.  Elastomeric impression materials: effect of bulk on accuracy. , 1979, The Journal of prosthetic dentistry.

[5]  M. Hemphill,et al.  Impression materials and techniques used for cast restorations in eight states. , 1980, Journal of the American Dental Association.

[6]  T J Bomberg,et al.  Impression material thickness in stock and custom trays. , 1985, The Journal of prosthetic dentistry.

[7]  G. M. Smith,et al.  Effect of impression tray design and impression technique upon the accuracy of stone casts produced from a putty-wash polyvinyl siloxane impression material. , 1991, Journal of dentistry.

[8]  W. Chee,et al.  Polyvinyl siloxane impression materials: a review of properties and techniques. , 1992, The Journal of prosthetic dentistry.

[9]  R. Noort Introduction to Dental Materials , 1994 .

[10]  K. Basford,et al.  A laboratory study of dimensional changes for three elastomeric impression materials using custom and stock trays. , 1996, Australian dental journal.

[11]  T. Brosh,et al.  Accuracy of three polyvinyl siloxane putty-wash impression techniques. , 2000, The Journal of prosthetic dentistry.

[12]  D. M. Clark,et al.  The use of specific dental school-taught restorative techniques by practicing clinicians. , 2001, Journal of dental education.

[13]  J. Nissan,et al.  Effect of wash bulk on the accuracy of polyvinyl siloxane putty-wash impressions. , 2002, Journal of oral rehabilitation.

[14]  Terry E Donovan,et al.  A review of contemporary impression materials and techniques. , 2004, Dental clinics of North America.

[15]  G. H. Johnson,et al.  Accuracy of newly formulated fast-setting elastomeric impression materials. , 2005, The Journal of prosthetic dentistry.

[16]  H. Rudolph,et al.  Clinical parameters influencing the accuracy of 1- and 2-stage impressions: a randomized controlled trial. , 2008, The International journal of prosthodontics.

[17]  M. Schmitter,et al.  Accuracy of the newly formulated vinyl siloxanether elastomeric impression material. , 2010, The Journal of prosthetic dentistry.

[18]  Andreas Syrek,et al.  Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. , 2010, Journal of dentistry.

[19]  Douglas A Terry,et al.  The custom impression tray: fabrication and utilization. , 2010, Dentistry today.

[20]  Techkouhie A Hamalian,et al.  Impression materials in fixed prosthodontics: influence of choice on clinical procedure. , 2011, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[21]  H. Aeran,et al.  Evaluation of Effect of Tray Space on the Accuracy of Condensation Silicone, Addition Silicone and Polyether Impression Materials: An In Vitro Study , 2012, Journal of Indian Prosthodontic Society.

[22]  Kishan Singh,et al.  Effect of different impression techniques on the dimensional accuracy of impressions using various elastomeric impression materials: an in vitro study. , 2012, The journal of contemporary dental practice.

[23]  Anshul Chugh,et al.  Accuracy of Different Putty-Wash Impression Techniques with Various Spacer Thickness , 2012, International journal of clinical pediatric dentistry.

[24]  W. Finger,et al.  Effects of the space for wash materials on sulcus depth reproduction with addition-curing silicone using two-step putty-wash technique. , 2013, Dental materials journal.

[25]  V. Chitre,et al.  A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression Material , 2013, Journal of Indian Prosthodontic Society.

[26]  Ramandeep Dugal,et al.  Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study. , 2013, Journal of international oral health : JIOH.

[27]  J. Nissan,et al.  Effect of various putty-wash impression techniques on marginal fit of cast crowns. , 2013, The International journal of periodontics & restorative dentistry.

[28]  E. Yuzbasioglu,et al.  Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes , 2014, BMC oral health.

[29]  Suprabha Rathee,et al.  A Comparison of Dimensional Accuracy of Addition Silicone of Different Consistencies with Two Different Spacer Designs - In-vitro Study. , 2014, Journal of clinical and diagnostic research : JCDR.

[30]  B. Wöstmann,et al.  Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients , 2015, Clinical Oral Investigations.

[31]  M. Zimmermanna,et al.  Intraoral scanning systems – a current overview , 2015 .

[32]  T. Attin,et al.  In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. , 2016, The Journal of prosthetic dentistry.

[33]  U. Brägger,et al.  Patient-centered outcomes comparing digital and conventional implant impression procedures: a randomized crossover trial. , 2016, Clinical oral implants research.

[34]  Konstantinos Chochlidakis,et al.  Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysis. , 2016, The Journal of prosthetic dentistry.

[35]  Daniel Edelhoff,et al.  Accuracy of five intraoral scanners compared to indirect digitalization , 2016, Clinical Oral Investigations.

[36]  T. Joda,et al.  Time efficiency, difficulty, and operator's preference comparing digital and conventional implant impressions: a randomized controlled trial , 2017, Clinical oral implants research.