Efficacy of thermal treatment and copper-silver ionization for controlling Legionella pneumophila in high-volume hot water plumbing systems in hospitals.

BACKGROUND Thermal treatment and copper-silver ionization are often used for controlling Legionella pneumophila in high-volume hospital plumbing systems, although the comparative efficacies of these measures in high-volume systems are unknown. METHODS Thermal treatment of a hot water circuit was accomplished by flushing hot water (> 60 degrees C) through distal fixtures for 10 minutes. Copper-silver ionization was conducted in three circuits by installing units into return lines immediately upstream from hot water tanks. Recovery rates of L. pneumophila were monitored by culturing swab samples from faucets. Concentrations of copper and silver in water samples were determined by atomic absorption spectrophotometry. RESULTS Four heat-flush treatments failed to provide long-term control of L. pneumophila. In contrast, ionization treatment reduced the rate of recovery of L. pneumophila from 108 faucets from 72% to 2% within 1 month and maintained effective control for at least 22 months. Only three samples (1.9%) of hot water from faucets exceeded Environmental Protection Agency standards for silver, and none exceeded the standards for copper. Of 24 samples obtained from hot water tanks, 42% and 50% exceeded the silver and copper standards, respectively. CONCLUSIONS Copper-silver ionization effectively controls L. pneumophila in high-volume plumbing systems and is superior to thermal treatment; however, high concentrations of copper and silver can accumulate at the bottom of hot water tanks.

[1]  P W Muraca,et al.  Disinfection of water distribution systems for legionella: a review of application procedures and methodologies. , 1990, Infection control and hospital epidemiology.

[2]  R M Wadowsky,et al.  Multiplication of Legionella pneumophila in unsterilized tap water , 1982, Applied and environmental microbiology.

[3]  J. Dowling,et al.  Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures , 1982, Applied and environmental microbiology.

[4]  R. Wadowsky,et al.  Glycine-containing selective medium for isolation of Legionellaceae from environmental specimens , 1981, Applied and environmental microbiology.

[5]  J. Dowling,et al.  Multiplication of Legionella spp. in tap water containing Hartmannella vermiformis , 1991, Applied and environmental microbiology.

[6]  R. Wadowsky,et al.  Effect of temperature, pH, and oxygen level on the multiplication of naturally occurring Legionella pneumophila in potable water , 1985, Applied and environmental microbiology.

[7]  R. Breiman,et al.  Association of shower use with Legionnaires' disease. Possible role of amoebae. , 1990, JAMA.

[8]  R. Weaver,et al.  Detection of Legionnaires disease bacteria by direct immunofluorescent staining , 1978, Journal of clinical microbiology.

[9]  M. Para,et al.  Aerosols containing Legionella pneumophila generated by shower heads and hot-water faucets , 1985, Applied and environmental microbiology.

[10]  J. Wells,et al.  Isolation of Legionella spp. from environmental water samples by low-pH treatment and use of a selective medium , 1981, Journal of clinical microbiology.

[11]  C. Gerba,et al.  Efficacy of copper and silver ions and reduced levels of free chlorine in inactivation of Legionella pneumophila , 1989, Applied and environmental microbiology.

[12]  J. Sýkora,et al.  Growth-supporting activity for Legionella pneumophila in tap water cultures and implication of hartmannellid amoebae as growth factors , 1988, Applied and environmental microbiology.

[13]  Charles P. Gerba,et al.  The molecular mechanisms of copper and silver ion disinfection of bacteria and viruses , 1988 .

[14]  E. Wald,et al.  Field inversion gel electrophoretic analysis of Legionella pneumophila strains associated with nosocomial legionellosis in children , 1996, Journal of clinical microbiology.

[15]  R. Slack,et al.  Outbreak of Legionnaires' disease at University Hospital, Nottingham. Epidemiology, microbiology and control , 1993, Epidemiology and Infection.

[16]  V. Yu,et al.  Ubiquitousness of Legionella pneumophila in the water supply of a hospital with endemic Legionnaires' disease. , 1982, The New England journal of medicine.

[17]  V L Yu,et al.  Controlled evaluation of copper-silver ionization in eradicating Legionella pneumophila from a hospital water distribution system. , 1994, The Journal of infectious diseases.