Effects of electromagnetic radiation from 3G mobile phone on heart rate, blood pressure and ECG parameters in rats

Effects of electromagnetic energy radiated from mobile phones (MPs) on heart is one of the research interests. The current study was designed to investigate the effects of electromagnetic radiation (EMR) from third-generation (3G) MP on the heart rate (HR), blood pressure (BP) and ECG parameters and also to investigate whether exogenous melatonin can exert any protective effect on these parameters. In this study 36 rats were randomized and evenly categorized into 4 groups: group 1 (3G-EMR exposed); group 2 (3G-EMR exposed + melatonin); group 3 (control) and group 4 (control + melatonin). The rats in groups 1 and 2 were exposed to 3G-specific MP’s EMR for 20 days (40 min/day; 20 min active (speech position) and 20 min passive (listening position)). Group 2 was also administered with melatonin for 20 days (5 mg/kg daily during the experimental period). ECG signals were recorded from cannulated carotid artery both before and after the experiment, and BP and HR were calculated on 1st, 3rd and 5th min of recordings. ECG signals were processed and statistically evaluated. In our experience, the obtained results did not show significant differences in the BP, HR and ECG parameters among the groups both before and after the experiment. Melatonin, also, did not exhibit any additional effects, neither beneficial nor hazardous, on the heart hemodynamics of rats. Therefore, the strategy (noncontact) of using a 3G MP could be the reason for ineffectiveness; and use of 3G MP, in this perspective, seems to be safer compared to the ones used in close contact with the head. However, further study is needed for standardization of such an assumption.

[1]  Fehmi Ozguner,et al.  No effects of 900 MHz and 1800 MHz electromagnetic field emitted from cellular phone on nocturnal serum melatonin levels in rats , 2005, Toxicology and industrial health.

[2]  Seung-Kwon Myung,et al.  Mobile phone use and risk of tumors: a meta-analysis. , 2009, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[3]  Anthony T Barker,et al.  The effect of GSM and TETRA mobile handset signals on blood pressure, catechol levels and heart rate variability. , 2007, Bioelectromagnetics.

[4]  Paul K. Joseph,et al.  Effect of mobile phone radiation on heart rate variability , 2008, Comput. Biol. Medicine.

[5]  O. Pechanova,et al.  Potential roles of melatonin and chronotherapy among the new trends in hypertension treatment , 2009, Journal of pineal research.

[6]  Fehmi Ozguner,et al.  Mobile phone-induced myocardial oxidative stress: protection by a novel antioxidant agent caffeic acid phenethyl ester , 2005, Toxicology and industrial health.

[7]  A. Gorąca,et al.  The influence of low-frequency magnetic field on plasma antioxidant capacity and heart rate. , 2009, Wiadomosci lekarskie.

[8]  A. Acet,et al.  Effects of physiological and pharmacological concentrations of melatonin on ischemia–reperfusion arrhythmias in rats: can the incidence of sudden cardiac death be reduced? , 2002, Journal of pineal research.

[9]  M Koivisto,et al.  GSM phone signal does not produce subjective symptoms , 2001, Bioelectromagnetics.

[10]  R. Reiter,et al.  A review of the evidence supporting melatonin's role as an antioxidant , 1995, Journal of pineal research.

[11]  S. Szmigielski,et al.  Alteration of diurnal rhythms of blood pressure and heart rate to workers exposed to radiofrequency electromagnetic fields. , 1998, Blood pressure monitoring.

[12]  Fehmi Ozguner,et al.  Comparative analysis of the protective effects of melatonin and caffeic acid phenethyl ester (CAPE) on mobile phone-induced renal impairment in rat , 2005, Molecular and Cellular Biochemistry.

[13]  Witold Pilecki,et al.  The influence of the call with a mobile phone on heart rate variability parameters in healthy volunteers. , 2008, Industrial health.

[14]  R Kavet,et al.  Inconsistent suppression of nocturnal pineal melatonin synthesis and serum melatonin levels in rats exposed to pulsed DC magnetic fields. , 1998, Bioelectromagnetics.

[15]  Fehmi Ozguner,et al.  900 MHz radiofrequency-induced histopathologic changes and oxidative stress in rat endometrium: protection by vitamins E and C , 2007, Toxicology and industrial health.

[16]  Ömer Akyol,et al.  Effects of electromagnetic radiation from a cellular telephone on the oxidant and antioxidant levels in rabbits , 2002, Cell biochemistry and function.

[17]  S. Uğraş,et al.  The effects of microwave emitted by cellular phones on ovarian follicles in rats , 2009, Archives of Gynecology and Obstetrics.

[18]  Katia Vangelova,et al.  Cardiovascular risk in operators under radiofrequency electromagnetic radiation. , 2006, International journal of hygiene and environmental health.

[19]  I. Meral,et al.  Effects of 900-MHz electromagnetic field emitted from cellular phone on brain oxidative stress and some vitamin levels of guinea pigs , 2007, Brain Research.

[20]  The cardiac effects of a mobile phone positioned closest to the heart. , 2009, Anadolu kardiyoloji dergisi : AKD = the Anatolian journal of cardiology.

[21]  Mehmet Balci,et al.  Effects of Mobile Phones on Oxidant/Antioxidant Balance in Cornea and Lens of Rats , 2007, Current eye research.

[22]  Selcuk Comlekci,et al.  Endometrial apoptosis induced by a 900-MHz mobile phone: Preventive effects of vitamins E and C , 2006, Advances in therapy.

[23]  Kanako Wake,et al.  Short term exposure to 1439 MHz pulsed TDMA field does not alter melatonin synthesis in rats , 2005, Bioelectromagnetics.

[24]  N. Panda,et al.  Audiologic disturbances in long-term mobile phone users. , 2010, Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale.

[25]  Selcuk Comlekci,et al.  Protective effects of melatonin and caffeic acid phenethyl ester against retinal oxidative stress in long-term use of mobile phone: A comparative study , 2006, Molecular and Cellular Biochemistry.

[26]  Clemens Dasenbrock Animal carcinogenicity studies on radiofrequency fields related to mobile phones and base stations. , 2005, Toxicology and applied pharmacology.

[27]  James R. Jauchem,et al.  Effects of low-level radio-frequency (3kHz to 300GHz) energy on human cardiovascular, reproductive, immune, and other systems: a review of the recent literature. , 2008, International journal of hygiene and environmental health.

[28]  Fehmi Ozguner,et al.  Oxidative damage in the kidney induced by 900-MHz-emitted mobile phone: protection by melatonin. , 2005, Archives of medical research.

[29]  M. Mailankot,et al.  Radio Frequency Electromagnetic Radiation (RF-EMR) from GSM (0.9/1.8GHZ) Mobile Phones Induces Oxidative Stress and Reduces Sperm Motility in Rats , 2009, Clinics.

[30]  H. Parlakpınar,et al.  Physiological and pharmacological concentrations of melatonin protect against cisplatin‐induced acute renal injury , 2002, Journal of pineal research.

[31]  R. Reiter,et al.  Reducing oxidative/nitrosative stress: a newly-discovered genre for melatonin , 2009, Critical reviews in biochemistry and molecular biology.

[32]  J. Walleczek,et al.  Mechanisms of electromagnetic interaction with cellular systems , 1992, Naturwissenschaften.

[33]  Clint Smith,et al.  3G Wireless Networks , 2001 .

[34]  László Hejjel,et al.  The application of surface plethysmography for heart rate variability analysis after GSM radiofrequency exposure. , 2006, Journal of biochemical and biophysical methods.

[35]  Harri Lindholm,et al.  Cellular phone use does not acutely affect blood pressure or heart rate of humans , 2004, Bioelectromagnetics.

[36]  K. Patrick,et al.  Health and the mobile phone. , 2008, American journal of preventive medicine.

[37]  Ashok Agarwal,et al.  Pathophysiology of cell phone radiation: oxidative stress and carcinogenesis with focus on male reproductive system , 2009, Reproductive biology and endocrinology : RB&E.