Ultrathin Injectable Sensors of Temperature, Thermal Conductivity, and Heat Capacity for Cardiac Ablation Monitoring

Knowledge of the distributions of temperature in cardiac tissue during and after ablation is important in advancing a basic understanding of this process, and for improving its efficacy in treating arrhythmias. Technologies that enable real-time temperature detection and thermal characterization in the transmural direction can help to predict the depths and sizes of lesion that form. Herein, materials and designs for an injectable device platform that supports precision sensors of temperature and thermal transport properties distributed along the length of an ultrathin and flexible needle-type polymer substrate are introduced. The resulting system can insert into the myocardial tissue, in a minimally invasive manner, to monitor both radiofrequency ablation and cryoablation, in a manner that has no measurable effects on the natural mechanical motions of the heart. The measurement results exhibit excellent agreement with thermal simulations, thereby providing improved insights into lesion transmurality.

[1]  J. Rogers,et al.  Materials for multifunctional balloon catheters with capabilities in cardiac electrophysiological mapping and ablation therapy. , 2011, Nature materials.

[2]  Kyung-In Jang,et al.  3D multifunctional integumentary membranes for spatiotemporal cardiac measurements and stimulation across the entire epicardium , 2014, Nature Communications.

[3]  Yei Hwan Jung,et al.  Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics , 2013, Science.

[4]  Determination of Thermal Conductivity of Biomaterials in the Temperature Range 233–313K Using a Tiny Detector Made of a Self-Heated Thermistor , 2002 .

[5]  M. Fishbein,et al.  Early phase acute myocardial infarct size quantification: validation of the triphenyl tetrazolium chloride tissue enzyme staining technique. , 1981, American heart journal.

[6]  Yonggang Huang,et al.  Ultrathin conformal devices for precise and continuous thermal characterization of human skin. , 2013, Nature materials.

[7]  K. Maeda,et al.  Ventricular lead redundancy to prevent cardiovascular events and sudden death from lead fracture in pacemaker-dependent children. , 2015, Heart rhythm.

[8]  D. Haines,et al.  Basic Aspects of Radiofrequency Catheter Ablation , 1994, Journal of cardiovascular electrophysiology.

[9]  Yonggang Huang,et al.  Electronic sensor and actuator webs for large-area complex geometry cardiac mapping and therapy , 2012, Proceedings of the National Academy of Sciences.

[10]  I. Efimov,et al.  Fluorescent Imaging of a Dual-Pathway Atrioventricular-Nodal Conduction System , 2001, Circulation research.

[11]  Mark A. Wood,et al.  Histopathologic characterization of chronic radiofrequency ablation lesions for pulmonary vein isolation. , 2012, Journal of the American College of Cardiology.

[12]  José Jalife,et al.  2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation , 2012, Heart rhythm.

[13]  John A. Rogers,et al.  Thermal Transport Characteristics of Human Skin Measured In Vivo Using Ultrathin Conformal Arrays of Thermal Sensors and Actuators , 2015, PloS one.

[14]  Eung Je Woo,et al.  Temperature measurement within myocardium during in vitro RF catheter ablation , 2000, IEEE Transactions on Biomedical Engineering.

[15]  Douglas L. Packer,et al.  Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial. , 2014, Journal of the American College of Cardiology.

[16]  Nadir Saoudi,et al.  The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. , 2012, Heart rhythm.

[17]  L. Christophorou Science , 2018, Emerging Dynamics: Science, Energy, Society and Values.