Patient-specific numerical simulation of stent-graft deployment: Validation on three clinical cases.

Endovascular repair of abdominal aortic aneurysms faces some adverse outcomes, such as kinks or endoleaks related to incomplete stent apposition, which are difficult to predict and which restrain its use although it is less invasive than open surgery. Finite element simulations could help to predict and anticipate possible complications biomechanically induced, thus enhancing practitioners' stent-graft sizing and surgery planning, and giving indications on patient eligibility to endovascular repair. The purpose of this work is therefore to develop a new numerical methodology to predict stent-graft final deployed shapes after surgery. The simulation process was applied on three clinical cases, using preoperative scans to generate patient-specific vessel models. The marketed devices deployed during the surgery, consisting of a main body and one or more iliac limbs or extensions, were modeled and their deployment inside the corresponding patient aneurysm was simulated. The numerical results were compared to the actual deployed geometry of the stent-grafts after surgery that was extracted from postoperative scans. We observed relevant matching between simulated and actual deployed stent-graft geometries, especially for proximal and distal stents outside the aneurysm sac which are particularly important for practitioners. Stent locations along the vessel centerlines in the three simulations were always within a few millimeters to actual stents locations. This good agreement between numerical results and clinical cases makes finite element simulation very promising for preoperative planning of endovascular repair.

[1]  L. Horný,et al.  Axial prestretch and circumferential distensibility in biomechanics of abdominal aorta , 2013, Biomechanics and Modeling in Mechanobiology.

[2]  P Segers,et al.  Filling the void: a coalescent numerical and experimental technique to determine aortic stent graft mechanics. , 2013, Journal of biomechanics.

[3]  T. Corbett,et al.  Determination of coefficient of friction for self-expanding stent-grafts. , 2010, Journal of biomechanical engineering.

[4]  T. Christian Gasser,et al.  On the Impact of Intraluminal Thrombus Mechanical Behavior in AAA Passive Mechanics , 2015, Annals of Biomedical Engineering.

[5]  Pierre Badel,et al.  Computational comparison of the bending behavior of aortic stent-grafts. , 2012, Journal of the mechanical behavior of biomedical materials.

[6]  G. Antoniou,et al.  The hemodynamic impact of misalignment of fenestrated endografts: a computational study. , 2014, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[7]  P. Desgranges,et al.  Limb graft occlusion following EVAR: clinical pattern, outcomes and predictive factors of occurrence. , 2007, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[8]  C Kleinstreuer,et al.  Analysis of biomechanical factors affecting stent-graft migration in an abdominal aortic aneurysm model. , 2006, Journal of biomechanics.

[9]  P Segers,et al.  Virtual evaluation of stent graft deployment: a validated modeling and simulation study. , 2012, Journal of the mechanical behavior of biomedical materials.

[10]  J D Humphrey,et al.  Quantification of regional differences in aortic stiffness in the aging human. , 2014, Journal of the mechanical behavior of biomedical materials.

[11]  G. L. Moneta Endovascular versus Open Repair of Abdominal Aortic Aneurysm , 2010 .

[12]  J N Albertini,et al.  Pathophysiology of proximal perigraft endoleak following endovascular repair of abdominal aortic aneurysms: a study using a flow model. , 2001, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[13]  Miguel Castro,et al.  Prediction of deformations during endovascular aortic aneurysm repair using finite element simulation , 2013, Comput. Medical Imaging Graph..

[14]  R. Ogden,et al.  Hyperelastic modelling of arterial layers with distributed collagen fibre orientations , 2006, Journal of The Royal Society Interface.

[15]  Alessandro Reali,et al.  Patient-specific aortic endografting simulation: From diagnosis to prediction , 2013, Comput. Biol. Medicine.

[16]  Pascal Verdonck,et al.  A Novel Simulation Strategy for Stent Insertion and Deployment in Curved Coronary Bifurcations: Comparison of Three Drug-Eluting Stents , 2009, Annals of Biomedical Engineering.

[17]  Pierre Badel,et al.  Deployment of stent grafts in curved aneurysmal arteries: toward a predictive numerical tool , 2015, International journal for numerical methods in biomedical engineering.

[18]  D. Inzitari,et al.  Carotid Artery Stenting: First Consensus Document of the ICCS-SPREAD Joint Committee , 2006, Stroke.

[19]  Pierre Badel,et al.  Severe Bending of Two Aortic Stent-Grafts: An Experimental and Numerical Mechanical Analysis , 2012, Annals of Biomedical Engineering.

[20]  C. Kleinstreuera,et al.  Computational mechanics of Nitinol stent grafts , 2008 .

[21]  J Marzelle,et al.  Inter-observer variability in sizing fenestrated and/or branched aortic stent-grafts. , 2014, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[22]  Urs Utzinger,et al.  Microstructural and biomechanical alterations of the human aorta as a function of age and location , 2010, Biomechanics and modeling in mechanobiology.

[23]  Nan Xiao,et al.  A computational framework for investigating the positional stability of aortic endografts , 2012, Biomechanics and Modeling in Mechanobiology.

[24]  Jiaquan Xu,et al.  Deaths: final data for 2009. , 2011, National vital statistics reports : from the Centers for Disease Control and Prevention, National Center for Health Statistics, National Vital Statistics System.

[25]  S. Money,et al.  Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair. , 2002, Journal of vascular surgery.

[26]  David A. Vorp,et al.  Towards A Noninvasive Method for Determination of Patient-Specific Wall Strength Distribution in Abdominal Aortic Aneurysms , 2006, Annals of Biomedical Engineering.

[27]  R J Hinchliffe,et al.  Endovascular repair of abdominal aortic aneurysms in patients with severe angulation of the proximal neck using a flexible stent-graft: European Multicenter Experience. , 2006, The Journal of cardiovascular surgery.

[28]  M. Walsh,et al.  A computational study of the magnitude and direction of migration forces in patient-specific abdominal aortic aneurysm stent-grafts. , 2010, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[29]  Pierre Badel,et al.  A New Method for the In Vivo Identification of Mechanical Properties in Arteries From Cine MRI Images: Theoretical Framework and Validation , 2013, IEEE Transactions on Medical Imaging.

[30]  Ferdinando Auricchio,et al.  Shape-memory alloys: modelling and numerical simulations of the finite-strain superelastic behavior , 1997 .

[31]  J. Ricco,et al.  Selected Abstracts from the November Issue of the European Journal of Vascular and Endovascular Surgery , 2011 .

[32]  Gerhard A Holzapfel,et al.  Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs. , 2005, Journal of biomechanical engineering.

[33]  Pierre Badel,et al.  Finite Element Analysis of the Mechanical Performances of 8 Marketed Aortic Stent-Grafts , 2013, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[34]  Christopher K Zarins,et al.  Preliminary 3D computational analysis of the relationship between aortic displacement force and direction of endograft movement. , 2010, Journal of vascular surgery.

[35]  Larry H Hollier,et al.  Predicting iliac limb occlusions after bifurcated aortic stent grafting: anatomic and device-related causes. , 2002, Journal of vascular surgery.

[36]  F. Auricchio,et al.  Carotid artery stenting simulation: from patient-specific images to finite element analysis. , 2011, Medical engineering & physics.

[37]  Jean-Noël Albertini,et al.  Aorfix Stent Graft for Abdominal Aortic Aneurysms Reduces the Risk of Proximal Type 1 Endoleak in Angulated Necks: Bench-Test Study , 2005, Vascular.

[38]  Samy Missoum,et al.  Simulation and probabilistic failure prediction of grafts for aortic aneurysm , 2010 .

[39]  D. Saloner,et al.  Computational Fluid Dynamics within Bifurcated Abdominal Aortic Stent-Grafts , 2007, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[40]  Christian Geindreau,et al.  Influence of a Poro-Mechanical Modeling of the Intra-Luminal Thrombus and the Anisotropy of the Arterial Wall on the Prediction of the Abdominal Aortic Aneurysm Rupture , 2013 .