Optimization of the Circuit Configuration of a Pulsatile ECLS: An In Vivo Experimental Study

An extracorporeal life support system (ECLS) with a conventional membrane oxygenator requires a driving force for the blood to pass through hollow fiber membranes. We hypothesized that if a gravity-flow hollow fiber membrane oxygenator is installed in the circuit, the twin blood sacs of a pulsatile ECLS (the Twin-Pulse Life Support, T-PLS) can be placed downstream of the membrane oxygenator. This would increase pump output by doubling pulse rate at a given pump-setting rate while maintaining effective pulsatility. The purpose of this study was to determine the optimal circuit configuration for T-PLS with respect to energy and pump output. Animals were randomly assigned to 2 groups in a total cardiopulmonary bypass model. In the serial group, a conventional membrane oxygenator was located between the twin blood sacs of the T-PLS. In the parallel group, the twin blood sacs were placed downstream of the gravity-flow membrane oxygenator. Energy equivalent pressure (EEP), surplus hemodynamic energy (SHE) and pump output were collected at the different pump-setting rates of 30, 40, and 50 beats per minute (BPM). At a given pump-setting rate the pulse rate doubled in the parallel group. Percent changes of mean arterial pressure to EEP were 13.0 ± 1.7, 12.0 ± 1.9, and 7.6 ± 0.9% in the parallel group, while 22.5 ± 2.4, 23.2 ± 1.9, and 21.8 ± 1.4 in the serial group at 30, 40, and 50 BPM of pump-setting rates. SHE at each pump setting rate was 20,131 ± 1,408, 21,739 ± 2,470, and 15,048 ± 2,108 erg/cm3 in the parallel group, while 33,968 ± 3,001, 38,232 ± 3,281, 37,964 ± 2,693 erg/cm3 in the serial group. Pump output was higher in the parallel circuit at 40, and 50 BPM pump-setting rates (3.1 ± 0.2, 3.7 ± 0.2 L/min vs. 2.2 ± 0.1 and 2.5 ± 0.1 L/min, respectively, p =0.01). Either parallel or serial circuit configuration of T-PLS generates effective pulsatility. As for the pump out, the parallel circuit configuration provides higher flow than the serial circuit configuration by doubling the pulse rate at a given pump-setting rate.

[1]  Kyung Sun,et al.  In Vitro Evaluation of the Performance of Korean Pulsatile ECLS (T-PLS) Using Precise Quantification of Pressure-Flow Waveforms , 2005, ASAIO journal.

[2]  Kwang Taik Kim,et al.  The Effects of Pulsatile versus Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow during Cardiac Arrest , 2005, The International journal of artificial organs.

[3]  Gerson Rosenberg,et al.  Major factors in the controversy of pulsatile versus nonpulsatile flow during acute and chronic cardiac support. , 2005, ASAIO journal.

[4]  K. Sun,et al.  The Effects of Pulsatile Flow Upon Renal Tissue Perfusion During Cardiopulmonary Bypass: A Comparative Study of Pulsatile and Nonpulsatile Flow , 2005, ASAIO journal.

[5]  John L. Myers,et al.  Precise Quantification of Pressure Flow Waveforms of a Pulsatile Ventricular Assist Device , 2005, ASAIO journal.

[6]  A. Undar,et al.  Comparison of hollow-fiber membrane oxygenators in terms of pressure drop of the membranes during normothermic and hypothermic cardiopulmonary bypass in neonates. , 2003, Perfusion.

[7]  K. Sun,et al.  Application of a pressure-relieving air compliance chamber in a single-pulsatile extracorporeal life support system: an experimental study. , 2004, Artificial organs.

[8]  Akif Ündar,et al.  Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support. , 2004 .

[9]  K. Sun,et al.  A preclinical cadaver fitting study of implantable biventricular assist device-- AnyHeart. , 2004, The International journal of artificial organs.

[10]  S. W. Choi,et al.  In vivo evaluation of the pulsatile ECLS sysem , 2003, Journal of Artificial Organs.

[11]  K. Sun,et al.  Korean artificial heart (AnyHeart): an experimental study and the first human application. , 2003, Artificial organs.

[12]  A. Undar Energy equivalent pressure formula is for precise quantification of different perfusion modes. , 2003, Annals of Thoracic Surgery.

[13]  S. W. Choi,et al.  Applications of the pulsatile flow versatile ECLS: in vivo studies. , 2003, The International journal of artificial organs.

[14]  C. Fraser,et al.  Impact of membrane oxygenators on pulsatile versus nonpulsatile perfusion in a neonatal model , 2000, Perfusion.

[15]  A Undar,et al.  Defining pulsatile perfusion: quantification in terms of energy equivalent pressure. , 1999, Artificial organs.

[16]  G Wright,et al.  Hemodynamic analysis could resolve the pulsatile blood flow controversy. , 1994, The Annals of thoracic surgery.

[17]  R B Shepard,et al.  Energy equivalent pressure. , 1966, Archives of surgery.