Present status of immediate loading of oral implants.

PROBLEM Several conditions must be present to obtain implant integration and long-term clinical success when using the one-stage implant placement procedure with immediate loading. These conditions include (1) primary stability, (2) sufficient bone quality, and (3) elimination of micromovement of the implant before osseous integration is complete. PURPOSE This report presents the results of research on immediate loading using a new and innovative implant design, Ankylos. METHODS The author reviewed clinical studies of immediate loaading or oral implants, including two treatment options, removable overdentures and fixed reconstructions. RESULTS Animal studies have demonstrated that successful osseointegration of Ankylos implants can occur (Figure 2D) when implants are placed and loaded immediately in the presence of some specific conditions. The histological findings involving implants that were placed in humans and immediately loaded showed no fibrous tissue formation (encapsulation). The bone-to-implant contact (osseointegration) was found to be excellent between the immediately-loaded implants and the surrounding alveolar bone. CONCLUSION The Ankylos implant system with its progressive thread design successfully promotes primary, clinical stability at the time of implant placement. Several animal studies have shown that in implant restorations placed in similar areas of poor bone quality (ie, maxilla and the posterior part of the mandible), the concept of immediate loading can result in long-term clinical success, when loading forces are controlled. Immobilization of the implants and soft diet recommendations that reduce micromovement at the bone-to-implant interface will improve long-term clinical success. In summary, the Ankylos implant is well designed for one-stage placement with immediate loading, as well as for two-stage treatment protocols. Both clinical protocols will result in long-term clinical survival.

[1]  L. Sennerby,et al.  Histology of retrieved immediately and early loaded oxidized implants: light microscopic observations after 5 to 9 months of loading in the posterior mandible. , 2003, Clinical implant dentistry and related research.

[2]  J. Rubenstein,et al.  Ten-year results for Brånemark implants immediately loaded with fixed prostheses at implant placement. , 1997, The International journal of oral & maxillofacial implants.

[3]  R. Jaffin,et al.  The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis. , 1991, Journal of periodontology.

[4]  D. Buser,et al.  Tissue integration of one-stage ITI implants: 3-year results of a longitudinal study with Hollow-Cylinder and Hollow-Screw implants. , 1991, The International journal of oral & maxillofacial implants.

[5]  H. F. Morris,et al.  The ankylos endosseous dental implant: assessment of stability up to 18 months with the Periotest. , 2000, The Journal of oral implantology.

[6]  R. Glauser,et al.  Immediate occlusal loading of Brånemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study. , 2003, Clinical implant dentistry and related research.

[7]  G. Romanos,et al.  Immediate implant-supported mandibular overdentures retained by conical crowns : A new treatment concept , 2002 .

[8]  M. Chiapasco,et al.  Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases. , 1997, Clinical oral implants research.

[9]  G. Romanos,et al.  Peri-implant soft tissue integration of immediately loaded implants in the posterior macaque mandible: a histomorphometric study. , 2003, Journal of periodontology.

[10]  P. Frandsen,et al.  Holding power of different screws in the femoral head. A study in human cadaver hips. , 1984, Acta orthopaedica Scandinavica.

[11]  G. Romanos,et al.  Single molar replacement with a progressive thread design implant system: a retrospective clinical report. , 2000, The International journal of oral & maxillofacial implants.

[12]  J. M. Lee,et al.  Observations on the Effect of Movement on Bone Ingrowth into Porous‐Surfaced Implants , 1986, Clinical orthopaedics and related research.

[13]  A Sarmiento,et al.  Fracture healing in rat femora as affected by functional weight-bearing. , 1977, The Journal of bone and joint surgery. American volume.

[14]  D P Tarnow,et al.  Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data. , 1997, The International journal of oral & maxillofacial implants.

[15]  R. Haddad,et al.  The effect of surface treatments on the interface mechanics of LTI pyrolytic carbon implants. , 1985, Journal of biomedical materials research.

[16]  J Kenwright,et al.  The influence of induced micromovement upon the healing of experimental tibial fractures. , 1985, The Journal of bone and joint surgery. British volume.

[17]  A. Quayle Tissue integration in oral, orthopaedic and maxillofacial reconstruction , 1993 .

[18]  G. Romanos,et al.  Peri-implant bone reactions to immediately loaded implants. An experimental study in monkeys. , 2001, Journal of periodontology.

[19]  P. Branemark,et al.  Brånemark Novum: a new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study. , 1999, Clinical implant dentistry and related research.

[20]  J. Ganeles,et al.  Immediate loading of implants with fixed restorations in the completely edentulous mandible: report of 27 patients from a private practice. , 2001, The International journal of oral & maxillofacial implants.

[21]  K. Rungcharassaeng,et al.  Scientific rationale for the surgical and prosthodontic protocol for immediately loaded root form implants in the completely edentulous patient. , 2000, The Journal of oral implantology.

[22]  Paul Suetens,et al.  A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. , 2002, The International journal of oral & maxillofacial implants.

[23]  D. Misiek,et al.  Titanium plasma-sprayed (TPS) screw implants for the reconstruction of the edentulous mandible. , 1986, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[24]  G. Romanos Treatment of advanced periodontal destruction with immediately loaded implants and simultaneous bone augmentation: a case report. , 2003, Journal of periodontology.

[25]  J B Brunski,et al.  Avoid pitfalls of overloading and micromotion of intraosseous implants. , 1993, Dental implantology update.

[26]  O. Beirne,et al.  Histologic evaluation of hydroxylapatite-coated versus uncoated titanium blade implants in delayed and immediately loaded applications. , 1991, The International journal of oral & maxillofacial implants.

[27]  C. Bünger,et al.  Tissue ingrowth into titanium and hydroxyapatite‐coated implants during stable and unstable mechanical conditions , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[28]  R A Jaffin,et al.  Immediate loading of implants in partially and fully edentulous jaws: a series of 27 case reports. , 2000, Journal of periodontology.

[29]  G. Romanos,et al.  Histologic and histomorphometric evaluation of peri-implant bone subjected to immediate loading: an experimental study with Macaca fascicularis. , 2002, The International journal of oral & maxillofacial implants.

[30]  W. Becker,et al.  Early functional loading at 5 days for Brånemark implants placed into edentulous mandibles: a prospective, open-ended, longitudinal study. , 2003, Journal of periodontology.

[31]  M. Lišková,et al.  Reaction of bone to mechanical stimuli. 3. Microstructure of compact bone of rabbit tibia after intermittent loading. , 1972, Acta anatomica.

[32]  S D Cook,et al.  The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials. , 1987, Journal of biomedical materials research.

[33]  J. Hert,et al.  Reaction of bone to mechanical stimuli , 1972 .

[34]  D Buser,et al.  Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. , 1997, Clinical oral implants research.

[35]  M. Martignoni,et al.  Immediate loading of Brånemark System TiUnite and machined-surface implants in the posterior mandible: a randomized open-ended clinical trial. , 2003, Clinical implant dentistry and related research.

[36]  A. Piattelli,et al.  Immediate loading of titanium plasma-sprayed implants: an histologic analysis in monkeys. , 1998, Journal of periodontology.

[37]  A. Scarano,et al.  Immediate loading of titanium plasma-sprayed screw-shaped implants in man: a clinical and histological report of two cases. , 1997, Journal of periodontology.

[38]  G. Wolfinger,et al.  IMMEDIATE LOADING OF BRÅNEMARK IMPLANTS IN EDENTULOUS MANDIBLES: A PRELIMINARY REPORT , 1997, Implant dentistry.

[39]  P. Aspenberg,et al.  Effects of mechanical stimulation on the differentiation of hard tissues. , 1993, Biomaterials.

[40]  H. Tsuru,et al.  The effects of early occlusal loading on one-stage titanium alloy implants in beagle dogs: a pilot study. , 1993, The Journal of prosthetic dentistry.

[41]  H. F. Morris,et al.  AICRG, Part II: Crestal bone loss associated with the Ankylos implant: loading to 36 months. , 2004, The Journal of oral implantology.

[42]  S. Szmukler‐Moncler,et al.  Immediate loading of Osseotite implants: a case report and histologic analysis after 4 months of occlusal loading. , 2001, The International journal of periodontics & restorative dentistry.

[43]  L. Rose,et al.  Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics--a technique reexamined: two case reports. , 1995, The International journal of periodontics & restorative dentistry.

[44]  J L Cunningham,et al.  Axial movement and tibial fractures. A controlled randomised trial of treatment. , 1991, The Journal of bone and joint surgery. British volume.

[45]  K. Yamamoto,et al.  Immediate loading of Brånemark system implants following placement in edentulous patients: a clinical report. , 2000, The International journal of oral & maxillofacial implants.

[46]  P. Branemark Osseointegration and its experimental background. , 1983, The Journal of prosthetic dentistry.

[47]  P. Glantz,et al.  Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study. , 1999, Clinical oral implants research.

[48]  K. Donath,et al.  RETRIEVAL ANALYSES OF A BLADE IMPLANT AFTER 231 MONTHS OF CLINICAL FUNCTION , 1992, Implant dentistry.

[49]  A. Piattelli,et al.  Immediate functional and non-functional loading of dental implants: a 2- to 60-month follow-up study of 646 titanium implants. , 2003, Journal of periodontology.

[50]  K. Søballe,et al.  Hydroxyapatite ceramic coating for bone implant fixation. Mechanical and histological studies in dogs. , 1993, Acta orthopaedica Scandinavica. Supplementum.