Robot-assisted vitreoretinal surgery: development of a prototype and feasibility studies in an animal model.

PURPOSE To develop a prototype robotic system designed to assist vitreoretinal surgery and to evaluate its accuracy and maneuverability. DESIGN Experimental study. PARTICIPANTS This study used harvested porcine eyes. METHODS After development of a prototype robotic system, pointing accuracy tests of the system were performed on graph paper and in harvested porcine eyes. The average maximal deviation from the aiming point to the actual position of the tip of the instrument was compared between manually conducted procedures and those conducted with robotic assistance. The feasibility of creating posterior vitreous detachment (PVD), retinal vessel sheathotomy (RVS), and retinal vessel microcannulation also were evaluated in porcine eye models, and the success rates of 4 consecutive attempts for each kind of procedure were evaluated. MAIN OUTCOME MEASURES The average maximum deviation in pointing accuracy tests both on graph paper and in animal eye models was a main outcome measure. The success rate of making PVD, RVS, and retinal vessel microcannulation was the other primary outcome measure. RESULTS The pointing accuracy was superior with robotic assistance both on graph paper (327.0 microm vs. 32.3 microm) and in animal eye models (140.8 microm vs. 33.5 microm). Creating PVD, RVS, and retinal vessel microcannulation was feasible in 4 of 4 attempts, 4 of 4 attempts, and 2 of 4 attempts, respectively. The 2 failures in microcannulation were considered to be the result of difficulty in visual differentiation between the retinal vessel and retina in harvested porcine eyes. CONCLUSIONS Improved accuracy and desirable feasibility of a prototype robotic system to assist vitreoretinal surgery were shown in this study. Research for wider implementation of robot-assisted surgery should be continued; there are some hurdles to overcome.

[1]  J. Marescaux,et al.  Telerobotic Laparoscopic Cholecystectomy: Initial Clinical Experience With 25 Patients , 2001, Annals of surgery.

[2]  Michel Gagner,et al.  Robotics and general surgery. , 2003, The Surgical clinics of North America.

[3]  F. Mohr,et al.  Robot-assisted minimally invasive solo mitral valve operation. , 1998, The Journal of thoracic and cardiovascular surgery.

[4]  Jacques Marescaux,et al.  Robot-assisted remote surgery: technological advances, potential complications, and solutions. , 2004, Surgical technology international.

[5]  Jacques Marescaux,et al.  Transatlantic robot-assisted telesurgery , 2001, Nature.

[6]  C. Riviere,et al.  Characteristics of hand motion of eye surgeons , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[7]  M. Puhan,et al.  Robotic-assisted Versus Laparoscopic Cholecystectomy: Outcome and Cost Analyses of a Case-matched Control Study , 2008, Annals of surgery.

[8]  Michael P Esposito,et al.  Use of fourth arm in da Vinci robot-assisted extraperitoneal laparoscopic prostatectomy: novel technique. , 2006, Urology.

[9]  A. Galloway,et al.  Case report of robotic instrument-enhanced mitral valve surgery. , 2000, The Journal of thoracic and cardiovascular surgery.

[10]  H. Das,et al.  Dexterity-enhanced telerobotic microsurgery , 1997, 1997 8th International Conference on Advanced Robotics. Proceedings. ICAR'97.

[11]  J. Fanning,et al.  Robotic radical hysterectomy. , 2008, American journal of obstetrics and gynecology.

[12]  M. Mitsuishi,et al.  Microsurgical robotic system for the deep surgical field: development of a prototype and feasibility studies in animal and cadaveric models. , 2005, Journal of neurosurgery.

[13]  Cameron N. Riviere,et al.  Design of all-accelerometer inertial measurement unit for tremor sensing in hand-held microsurgical instrument , 2003, 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422).

[14]  Kevin C Zorn,et al.  Da Vinci robot error and failure rates: single institution experience on a single three-arm robot unit of more than 700 consecutive robot-assisted laparoscopic radical prostatectomies. , 2007, Journal of endourology.

[15]  K Kyoshima,et al.  Three-dimensional Hi-vision system for microneurosurgical documentation based on wide-vision telepresence system using one camera and one monitor. , 1993, Neurologia medico-chirurgica.

[16]  Cameron N. Riviere,et al.  Physiological tremor amplitude during retinal microsurgery , 2002, Proceedings of the IEEE 28th Annual Northeast Bioengineering Conference (IEEE Cat. No.02CH37342).

[17]  Cameron N. Riviere,et al.  A study of instrument motion in retinal microsurgery , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[18]  Peter Kazanzides,et al.  Development and Application of a New Steady-Hand Manipulator for Retinal Surgery , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[19]  A Tsirbas,et al.  Robotic ocular surgery , 2006, British Journal of Ophthalmology.