Auditory steady-state responses to multiple simultaneous stimuli

Steady-state responses can follow multiple simultaneous auditory stimuli. If the stimuli are modulated at different rates, responses specific to each stimulus can be assessed by measuring in the frequency domain response the spectral component corresponding to the rate of modulation. When each stimulus has a different carrier frequency or different ear of presentation, the responses when 8 stimuli are presented simultaneously are not significantly different than when each stimulus is presented alone. Since significant responses can be recognized down to intensities that average 14 dB above behavioral threshold, this technique may be useful in objective audiometry. It is also possible to record steady-state responses to multiple modulations of the same carrier frequency. In this case, the amplitude of the responses when the stimuli are combined is smaller than when the stimuli are presented alone. The decrease in amplitude depends upon the number of concomitant stimuli and their relative intensities. These effects are probably due to the compressive rectification occurring during cochlear transduction, and the data may be used to model cochlear processing of auditory stimuli.

[1]  A. Rechtschaffen,et al.  A manual of standardized terminology, technique and scoring system for sleep stages of human subjects , 1968 .

[2]  Robert D Frisina,et al.  Encoding of amplitude modulation in the gerbil cochlear nucleus: I. A hierarchy of enhancement , 1990, Hearing Research.

[3]  A. Rechtschaffen A manual of Standardized Terminology , 1968 .

[4]  D. Mountain,et al.  The envelope following response: Scalp potentials elicited in the mongolian gerbil using sinusoidally AM acoustic signals , 1992, Hearing Research.

[5]  S. Makeig,et al.  A 40-Hz auditory potential recorded from the human scalp. , 1981, Proceedings of the National Academy of Sciences of the United States of America.

[6]  D. Regan,et al.  A method of measuring the potentials evoked by simultaneous stimulation of different retinal regions. , 1970, Electroencephalography and clinical neurophysiology.

[7]  T W Picton,et al.  Human Auditory Steady‐State Response During General Anesthesia , 1990, Anesthesia and analgesia.

[8]  Masaru Aoyagi,et al.  Optimal modulation frequency for amplitude-modulation following response in young children during sleep , 1993, Hearing Research.

[9]  G. Pfurtscheller Handbook of electroencephalography and clinical neurophysiology , 1978 .

[10]  G M Clark,et al.  Auditory steady-state evoked potential in newborns. , 1994, British journal of audiology.

[11]  R. Dobie,et al.  Amplitude-modulation following response (AMFR): Effects of modulation rate, carrier frequency, age, and state , 1993, Hearing Research.

[12]  Brian C. J. Moore,et al.  Frequency Analysis and Pitch Perception , 1993 .

[13]  T W Picton,et al.  Reliability estimates for steady-state evoked potentials. , 1987, Electroencephalography and clinical neurophysiology.

[14]  T W Picton,et al.  Human Auditory Steady State Evoked Potentials during Sleep , 1985, Ear and hearing.

[15]  D P Corey,et al.  Kinetics of the receptor current in bullfrog saccular hair cells , 1983, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[16]  L. Zetterberg,et al.  Application of a computer-based model for EEG analysis. , 1971, Electroencephalography and clinical neurophysiology.

[17]  T W Picton,et al.  Potentials evoked by the sinusoidal modulation of the amplitude or frequency of a tone. , 1987, The Journal of the Acoustical Society of America.

[18]  C. Schreiner,et al.  Periodicity coding in the inferior colliculus of the cat. I. Neuronal mechanisms. , 1988, Journal of neurophysiology.

[19]  A Isaksson,et al.  Visual evaluation and computer analysis of the EEG--a comparison. , 1975, Electroencephalography and clinical neurophysiology.

[20]  M Hämäläinen,et al.  Neuromagnetic steady-state responses to auditory stimuli. , 1989, The Journal of the Acoustical Society of America.

[21]  E. Pöppel,et al.  Sensory information processing during general anaesthesia: effect of isoflurane on auditory evoked neuronal oscillations. , 1991, British journal of anaesthesia.

[22]  Ernst Pöppel,et al.  Anesthetic Control of 40-Hz Brain Activity and Implicit Memory , 1994, Consciousness and Cognition.

[23]  J. Henry,et al.  Multiple-stimulus method for rapid collection of auditory brainstem responses using high-frequency (> or = 8 kHz) tone bursts. , 1994, Journal of the American Academy of Audiology.

[24]  G M Clark,et al.  A comparison of steady-state evoked potentials to modulated tones in awake and sleeping humans. , 1991, The Journal of the Acoustical Society of America.

[25]  T W Picton,et al.  Human auditory steady state potentials. , 1984, Ear and hearing.

[26]  J. Victor,et al.  A new statistic for steady-state evoked potentials. , 1991, Electroencephalography and clinical neurophysiology.

[27]  D. Regan Human brain electrophysiology: Evoked potentials and evoked magnetic fields in science and medicine , 1989 .

[28]  Shigeyuki Kuwada,et al.  Scalp potentials of normal and hearing-impaired subjects in response to sinusoidally amplitude-modulated tones , 1986, Hearing Research.

[29]  T Fuse,et al.  Pure-tone threshold prediction by 80-Hz amplitude-modulation following response. , 1994, Acta oto-laryngologica. Supplementum.

[30]  T. Picton,et al.  Interweaving and overlapping of evoked potentials. , 1988, Electroencephalography and clinical neurophysiology.

[31]  M. P. Regan,et al.  The transducer characteristic of hair cells in the human ear: a possible objective measure , 1988, Brain Research.

[32]  M. P. Regan Linear half-wave rectification of modulated sinusoids , 1994 .