Improving the accuracy of dose estimates from automatically scored dicentric chromosomes by accounting for chromosome number

Abstract Purpose The traditional workflow for biological dosimetry based on manual scoring of dicentric chromosomes is very time consuming. Especially for large-scale scenarios or for low-dose exposures, high cell numbers have to be analyzed, requiring alternative scoring strategies. Semi-automatic scoring of dicentric chromosomes provides an opportunity to speed up the standard workflow of biological dosimetry. Due to automatic metaphase and chromosome detection, the number of counted chromosomes per metaphase is variable. This can potentially introduce overdispersion and statistical methods for conventional, manual scoring might not be applicable to data obtained by automatic scoring of dicentric chromosomes, potentially resulting in biased dose estimates and underestimated uncertainties. The identification of sources for overdispersion enables the development of methods appropriately accounting for increased dispersion levels. Materials and methods Calibration curves based on in vitro irradiated (137-Cs; 0.44 Gy/min) blood from three healthy donors were analyzed for systematic overdispersion, especially at higher doses (>2 Gy) of low LET radiation. For each donor, 12 doses in the range of 0–6 Gy were scored semi-automatically. The effect of chromosome number as a potential cause for the observed overdispersion was assessed. Statistical methods based on interaction models accounting for the number of detected chromosomes were developed for the estimation of calibration curves, dose and corresponding uncertainties. The dose estimation was performed based on a Bayesian Markov-Chain-Monte-Carlo method, providing high flexibility regarding the implementation of priors, likelihood and the functional form of the association between predictors and dicentric counts. The proposed methods were validated by simulations based on cross-validation. Results Increasing dose dependent overdispersion was observed for all three donors as well as considerable differences in dicentric counts between donors. Variations in the number of detected chromosomes between metaphases were identified as a major source for the observed overdispersion and the differences between donors. Persisting overdispersion beyond the contribution of chromosome number was modeled by a Negative Binomial distribution. Results from cross-validation suggested that the proposed statistical methods for dose estimation reduced bias in dose estimates, variability between dose estimates and improved the coverage of the estimated confidence intervals. However, the 95% confidence intervals were still slightly too permissive, suggesting additional unknown sources of apparent overdispersion. Conclusions A major source for the observed overdispersion could be identified, and statistical methods accounting for overdispersion introduced by variations in the number of detected chromosomes were developed, enabling more robust dose estimation and quantification of uncertainties for semi-automatic counting of dicentric chromosomes.

[1]  Krzysztof W Fornalski,et al.  Analytical and quasi-Bayesian methods as development of the iterative approach for mixed radiation biodosimetry , 2018, Radiation and environmental biophysics.

[2]  Pedro Puig,et al.  An application of compound Poisson modelling to biological dosimetry , 2011, Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[3]  Pedro Puig,et al.  A new Bayesian model applied to cytogenetic partial body irradiation estimation. , 2015, Radiation protection dosimetry.

[4]  T. Lörch,et al.  New developments in automated cytogenetic imaging: unattended scoring of dicentric chromosomes, micronuclei, single cell gel electrophoresis, and fluorescence signals , 2004, Cytogenetic and Genome Research.

[5]  Casper W. Berg,et al.  glmmTMB Balances Speed and Flexibility Among Packages for Zero-inflated Generalized Linear Mixed Modeling , 2017, R J..

[6]  Sandrine Roch-Lefevre,et al.  Detection of Partial-Body Exposure to Ionizing Radiation by the Automatic Detection of Dicentrics , 2012, Radiation research.

[7]  Elizabeth A Ainsbury,et al.  DOSE ESTIMATION SOFTWARE FOR RADIATION BIODOSIMETRY , 2010, Health physics.

[8]  R. Wilkins,et al.  QUICKSCAN DICENTRIC CHROMOSOME ANALYSIS FOR RADIATION BIODOSIMETRY , 2010, Health physics.

[9]  W. Kruskal,et al.  Use of Ranks in One-Criterion Variance Analysis , 1952 .

[10]  Ulrike Kulka,et al.  Cytogenetic damage analysed by the dicentric assay. , 2009, Annali dell'Istituto superiore di sanita.

[11]  G. Schwarz Estimating the Dimension of a Model , 1978 .

[12]  Laurence Roy,et al.  RENEB intercomparisons applying the conventional Dicentric Chromosome Assay (DCA) , 2017, International journal of radiation biology.

[13]  Volodymyr A Vinnikov,et al.  A comparison of six statistical distributions for analysis of chromosome aberration data for radiation biodosimetry. , 2013, Radiation protection dosimetry.

[14]  Arne Henningsen,et al.  maxLik: A package for maximum likelihood estimation in R , 2011, Comput. Stat..

[15]  Jochen Einbeck,et al.  Zero‐inflated regression models for radiation‐induced chromosome aberration data: A comparative study , 2016, Biometrical journal. Biometrische Zeitschrift.

[16]  R. Berk,et al.  Overdispersion and Poisson Regression , 2008 .

[17]  Jochen Einbeck,et al.  A statistical framework for radiation dose estimation with uncertainty quantification from the γ-H2AX assay , 2018, PloS one.

[18]  H. Akaike A new look at the statistical model identification , 1974 .

[19]  W Merkle,et al.  Statistical methods in regression and calibration analysis of chromosome aberration data , 1983, Radiation and environmental biophysics.

[20]  David Endesfelder,et al.  Automated scoring of dicentric chromosomes differentiates increased radiation sensitivity of young children after low dose CT exposure in vitro , 2018, International journal of radiation biology.

[21]  Gaetan Gruel,et al.  Biological Dosimetry by Automated Dicentric Scoring in a Simulated Emergency , 2013, Radiation research.

[22]  D. G. Papworth,et al.  Constructing a 2B Calibration Curve for Retrospective Dose Reconstruction , 2000 .

[23]  J F Barquinero,et al.  Automatic scoring of dicentric chromosomes as a tool in large scale radiation accidents. , 2013, Mutation research.

[24]  MASAO S. SASAKI,et al.  Biological Dosimetry in Atomic Bomb Survivors , 1968, Nature.

[25]  Pedro Puig,et al.  A new inverse regression model applied to radiation biodosimetry , 2015, Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[26]  Eric Grégoire,et al.  Strategy for Population Triage Based on Dicentric Analysis , 2009, Radiation research.

[27]  G. W. Dolphin,et al.  BIOLOGICAL DOSIMETRY WITH PARTICULAR REFERENCE TO CHROMOSOME ABERRATION ANALYSIS. A REVIEW OF METHODS. , 1969 .

[28]  I Słonecka,et al.  Simplified Bayesian method: application in cytogenetic biological dosimetry of mixed n + γ radiation fields , 2019, Radiation and environmental biophysics.

[29]  J. Lawless,et al.  Tests for Detecting Overdispersion in Poisson Regression Models , 1989 .

[30]  J. Hilbe Negative Binomial Regression: Index , 2011 .

[31]  Maurizio Marrale,et al.  UNCERTAINTY ON RADIATION DOSES ESTIMATED BY BIOLOGICAL AND RETROSPECTIVE PHYSICAL METHODS , 2018, Radiation protection dosimetry.

[32]  Martyn Plummer,et al.  JAGS: A program for analysis of Bayesian graphical models using Gibbs sampling , 2003 .

[33]  J F Barquinero,et al.  Biological Dosimetry Intercomparison Exercise: An Evaluation of Triage and Routine Mode Results by Robust Methods , 2011, Radiation research.

[34]  L. Marro,et al.  Validation of QuickScan Dicentric Chromosome Analysis for High Throughput Radiation Biological Dosimetry , 2012, Health physics.

[35]  Leonora Marro,et al.  Biological Dosimetry by the Triage Dicentric Chromosome Assay - Further validation of International Networking. , 2011, Radiation measurements.

[36]  D Lloyd,et al.  BIODOSIMETRY AND BIODOSIMETRY NETWORKS FOR MANAGING RADIATION EMERGENCY , 2018, Radiation protection dosimetry.

[37]  Matthew J. Denwood,et al.  runjags: An R Package Providing Interface Utilities, Model Templates, Parallel Computing Methods and Additional Distributions for MCMC Models in JAGS , 2016 .

[38]  D. G. Papworth Exact tests of fit for a poisson distribution , 2005, Computing.

[39]  Vesna Pajic,et al.  Inter-individual variability in the response of human peripheral blood lymphocytes to ionizing radiation: comparison of the dicentric and micronucleus assays , 2015, Radiation and environmental biophysics.