Flow-injection chemiluminescence sensor for the determination of isoniazid

[1]  Z. Song,et al.  Chemiluminescence sensor for isoniazid with controlled-reagent-release technology. , 2001, Talanta.

[2]  Z. Zhang,et al.  Flow-injection chemiluminescence determination of isoniazid using on-line electrogenerated BrO– as an oxidant , 1999 .

[3]  Jin‐Ming Lin,et al.  Flow injection chemiluminescent determination of trace amounts of hydrogen peroxide in snow-water using KIO4-K2CO3 system , 1998 .

[4]  W. Qin,et al.  Reagentless chemiluminescence flow sensor for sulfite , 1998 .

[5]  P. Y. Naidu,et al.  Rapid, Routine Method for the Analysis of Some Drugs with Bromate and Celestine Blue , 1998 .

[6]  W. Qin,et al.  Chemiluminescence flow sensor for the determination of vitamin B12 , 1997 .

[7]  W. Qin,et al.  Flow-Injection Chemiluminescence Sensor for the Determination of Free Chlorine in Tap Water , 1997 .

[8]  E. Wang,et al.  Detection of hydrazine, methylhydrazine, and isoniazid by capillary electrophoresis with a palladium-modified microdisk array electrode. , 1996, Analytical chemistry.

[9]  H. Yathirajan,et al.  Spectrophotometric determination of isoniazid with sodium 1,2-naphthoquinone-4-sulphonate and cetyltrimethyl ammonium bromide. , 1996, Talanta.

[10]  M. Yamada,et al.  Chemiluminescence Sensor with Mn(III)-Tetrakis (4-sulfonatophenyl)-porphyrin Immobilized on Dioctadecyldimethylammonium Chloride Bilayer Membranes Incorporated Into PVC Film , 1996 .

[11]  M. Dumontet,et al.  Rapid, specific and sensitive method for isoniazid determination in serum. , 1996, Journal of chromatography. B, Biomedical applications.

[12]  W. Yanjun,et al.  A flow-injection type chemiluminescence-based sensor for cyanide , 1995 .

[13]  G. Piancone,et al.  An HPLC screening method for the detection of isonicotinic acid hydrazide in cattle milk , 1995 .

[14]  N. Mahfouz,et al.  Colorimetric determination of isoniazid and its pharmaceutical formulations. , 1993, Talanta.

[15]  V. Gupta,et al.  A new spectrophotometric method for the determination of hydrazine in environmental samples , 1992 .

[16]  H. I. Subbagh,et al.  Spectrophotometric determination of isoniazid using ethyl 8-quinolinoxy acetate , 1992 .

[17]  M. Koupparis,et al.  Flow-injection stopped-flow kinetic spectrophotometric determination of drugs, based on micellar-catalysed reaction with 1-fluoro-2,4-dinitrobenzene. , 1991, Talanta.

[18]  T. Hobo,et al.  Chemiluminescence sensor with uranine immobilized on an anion-exchange resin for monitoring free chlorine in tap water , 1990 .

[19]  M. Timotheou-Potamia,et al.  Continuous-flow chemiluminescence determination of isoniazid by oxidation with N-bromosuccinimide. , 1990, The Analyst.

[20]  M. El-Kommos,et al.  Spectrophotometric determination of isoniazid using 6,7-dichloroquinoline-5,8-dione. , 1988, The Analyst.

[21]  P. Ioannou A simple and rapid fluorimetric method for the microdetermination of isonicotinic acid hydrazide. , 1987, Talanta.

[22]  R. W. Frei,et al.  A solid-state chemiluminescence detector for hydrogen peroxide based on an immobilized luminophore , 1985 .

[23]  J. Dixon,et al.  Spectrophotometric Determination of Vicinal Glycols , 1954 .