Tuning and amplification strategies for intravascular imaging coils

The manufacturing of intravascular imaging coils poses several challenges. Due to their size, it can be difficult to incorporate local matching networks and signal amplifiers. The goal of this study is to investigate tuning and amplification strategies for intravascular coils and to assess the signal‐to‐noise benefits of incorporating a matching network and/or miniature amplifier into catheter‐based intravascular imaging devices at various locations in the signal chain. The results suggest that the use of a low‐noise amplifier close to the receiving coil enables the use of miniature coaxial cables to be used despite being noisy. Moreover, an improvement in the signal‐to‐noise ratio of over 75% is presented over conventional intravascular coil configurations where the matching circuit and low‐noise amplifier are placed at the proximal end. Therefore, designing devices for intravascular applications capable of generating high signal‐to‐noise ratio images becomes more feasible, also allowing for significant reductions in scan time. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc.

[1]  R. Kaul,et al.  Microwave engineering , 1989, IEEE Potentials.

[2]  Volkmar Schulz,et al.  Transmission line for improved RF safety of interventional devices , 2005, Magnetic resonance in medicine.

[3]  Inder Bahl,et al.  Fundamentals of RF and Microwave Transistor Amplifiers , 2009 .

[4]  Arne Reykowski,et al.  Active device tracking and high‐resolution intravascular MRI using a novel catheter‐based, opposed‐solenoid phased array coil , 2004, Magnetic resonance in medicine.

[5]  H.T. Friis,et al.  Noise Figures of Radio Receivers , 1944, Proceedings of the IRE.

[6]  Klaus Scheffler,et al.  The Interventioal Device Tracking Using Miniaturized Micro Coils , 2009 .

[7]  Jörg Müller,et al.  Development of an Active Intravascular MR Device With an Optical Transmission System , 2008, IEEE Transactions on Medical Imaging.

[8]  D B Plewes,et al.  MR imaging of blood vessels with an intravascular coil , 1992, Journal of magnetic resonance imaging : JMRI.

[9]  R. Henkelman Measurement of signal intensities in the presence of noise in MR images. , 1985, Medical physics.

[10]  Wolfhard Semmler,et al.  MR‐guided intravascular procedures: Real‐time parameter control and automated slice positioning with active tracking coils , 2004, Journal of magnetic resonance imaging : JMRI.

[11]  Kevan J T Anderson,et al.  Forward‐looking intravascular orthogonal‐solenoid coil for imaging and guidance in occlusive arterial disease , 2008, Magnetic resonance in medicine.

[12]  William F. Egan Practical RF system design , 2003 .