Modeling of IEEE1588 on OPNET and Analysis of Asymmetric Synchronizing Error in Smart Substation

The IEEE1588 network time synchronization, matched with smart substation information network transmission, is becoming the next generation advanced data synchronization of the smart substation. It is known that the inherent asymmetry error of the network synchronization approach in the smart substation is highlighted, which is concerned particularly. This paper models the synchronization process of the IEEE1588 based on the communication simulation software of OPNET Modeler. Firstly, it builds the models of master-slave clock, IEEE1588 protocol and network synchroniza- tion model, and analyzes the composition and influencing factors of the asymmetry error. Secondly, it quantitatively analyzes the influence of the synchronous asymmetric error of the IEEE1588 affected by the network status differences and the clock synchronization signal transmission path differences. Then its correction method is analyzed, in order to improve the IEEE1588 synchronization reliability and gives the solutions to its application in smart substation.

[1]  Wei Yong-jun Effect of IEC 61850 Standard on Substation Automation System in China , 2010 .

[2]  Qin Yin-li A New IEEE 1588 Based Technology for Realizing the Sampled Values Synchronization on the Substation Process Bus , 2005 .

[3]  Ju Yang Modes of Web communication of digital substation , 2010 .

[4]  Chen Ye-zhao Researches on Time Synchronization Technology of Power Systems , 2007 .

[5]  Xia Wen-bo Construction of synchronous clock system of Guangdong power digital network , 2000 .

[6]  J. Schmid,et al.  Get on the digital bus to substation automation , 2007, IEEE Power and Energy Magazine.

[7]  Wang Song Error Analysis and Detection Method for IEEE 1588 Clock Synchronization System , 2010 .

[8]  Guo Jinghong The Research of Precision Time Protocol IEEE 1588 , 2009 .

[9]  Long Fei,et al.  Research of time synchronization in digital substation based on IEEE 1588 , 2010, The 2nd International Conference on Information Science and Engineering.

[10]  Yu Hong-wei Study on Method of Time Synchronization in Digital Substations , 2008 .

[11]  Zhao Yinfeng Analysis and Experiment of Transparent Clock in Time Synchronization System of Smart Substation , 2012 .

[12]  Peng An Realization of High Accuracy Synchronous Clock for Power System Based on GPS , 2011 .

[13]  Yan Zhi-hui Substation clock server meeting IEC61850 , 2010 .

[14]  J. Jasperneite,et al.  Enhancements to the time synchronization standard IEEE-1588 for a system of cascaded bridges , 2004, IEEE International Workshop on Factory Communication Systems, 2004. Proceedings..

[15]  H. P. Lips,et al.  Operational tests on HVDC thyristor modules in a synthetic test circuit for the Sylmar East Restoration Project , 1997 .