Tidal breathing parameters measured using structured light plethysmography in healthy children and those with asthma before and after bronchodilator

Structured light plethysmography (SLP) is a light‐based, noncontact technique that measures tidal breathing by monitoring displacements of the thoracoabdominal (TA) wall. We used SLP to measure tidal breathing parameters and their within‐subject variability (v) in 30 children aged 7–16 years with asthma and abnormal spirometry (forced expiratory volume in 1 sec [FEV1] <80% predicted) during a routine clinic appointment. As part of standard care, the reversibility of airway obstruction was assessed by repeating spirometry after administration of an inhaled bronchodilator. In this study, SLP was performed before and after bronchodilator administration, and also once in 41 age‐matched controls. In the asthma group, there was a significant increase in spirometry‐assessed mean FEV1 after administration of bronchodilator. Of all measured tidal breathing parameters, the most informative was the inspiratory to expiratory TA displacement ratio (IE50SLP, calculated as TIF50SLP/TEF50SLP, where TIF50SLP is tidal inspiratory TA displacement rate at 50% of inspiratory displacement and TEF50SLP is tidal expiratory TA displacement rate at 50% of expiratory displacement). Median (m) IE50SLP and its variability (vIE50SLP) were both higher in children with asthma (prebronchodilator) compared with healthy children (mIE50SLP: 1.53 vs. 1.22, P < 0.001; vIE50SLP: 0.63 vs. 0.47, P < 0.001). After administration of bronchodilators to the asthma group, mIE50SLP decreased from 1.53 to 1.45 (P = 0.01) and vIE50SLP decreased from 0.63 to 0.60 (P = 0.04). SLP‐measured tidal breathing parameters could differentiate between children with and without asthma and indicate a response to bronchodilator.

[1]  D M Caretti,et al.  Reliability of respiratory inductive plethysmography for measuring tidal volume during exercise. , 1994, American Industrial Hygiene Association journal.

[2]  J. Mead,et al.  Measurement of the separate volume changes of rib cage and abdomen during breathing. , 1967, Journal of applied physiology.

[3]  J. Stocks,et al.  Lung‐function tests in neonates and infants with chronic lung disease: Tidal breathing and respiratory control , 2006, Pediatric pulmonology.

[4]  R. Iles,et al.  Tidal breathing patterns derived from structured light plethysmography in COPD patients compared with healthy subjects , 2016, Medical devices.

[5]  C. Leung,et al.  American Thoracic Society/European Respiratory Society 2005 standardization of DLCO measurement: Impact on performance , 2008, Respirology.

[6]  G Schmalisch,et al.  Comparative investigations of algorithms for the detection of breaths in newborns with disturbed respiratory signals. , 1998, Computers and biomedical research, an international journal.

[7]  Joan Lasenby,et al.  SLP: A Zero-Contact Non-Invasive Method for Pulmonary Function Testing , 2010, BMVC.

[8]  B. Lesnick,et al.  Infant pulmonary function testing: overview of technology and practical considerations--new current procedural terminology codes effective 2010. , 2011, Chest.

[9]  Jeremy D Johnson,et al.  A stepwise approach to the interpretation of pulmonary function tests. , 2014, American family physician.

[10]  S. Kira,et al.  Variability of breath-by-breath tidal volume and its characteristics in normal and diseased subjects. Ventilatory monitoring with electrical impedance pneumography. , 1985, Japanese journal of medicine.

[11]  A. Winship Interest. , 1893 .

[12]  References , 1971 .

[13]  G. Bellon,et al.  Infant respiratory function testing , 1997 .

[14]  B. Naidu,et al.  Measuring changes in chest wall motion after lung resection using structured light plethysmography: a feasibility study. , 2016, Interactive cardiovascular and thoracic surgery.

[15]  J. Hankinson,et al.  General considerations for lung function testing , 2005, European Respiratory Journal.

[16]  C Weissman,et al.  Effect of respiratory apparatus on respiration. , 1984, Journal of applied physiology: respiratory, environmental and exercise physiology.

[17]  G. Viegi,et al.  Coming together: the ATS/ERS consensus on clinical pulmonary function testing , 2005, European Respiratory Journal.

[18]  Third Expert Panel on theDiagnosis,et al.  Expert Panel Report 3: Guidelines for the Diagnosis and Management of Asthma , 1997 .

[19]  D. Koller,et al.  Negative expiratory pressure: A new tool for evaluating lung function in children? , 2003, Pediatric pulmonology.

[20]  C. Roussos,et al.  Clinical review: Severe asthma , 2001, Critical care.

[21]  M A Sackner,et al.  Measurement of breath amplitudes: Comparison of three noninvasive respiratory monitors to integrated pneumotachograph , 1993, Pediatric pulmonology.

[22]  Martin J Tobin,et al.  Dyspnea and decreased variability of breathing in patients with restrictive lung disease. , 2002, American journal of respiratory and critical care medicine.

[23]  Per Capita,et al.  About the authors , 1995, Machine Vision and Applications.

[24]  Anna M. Barney,et al.  Evaluation of the agreement of tidal breathing parameters measured simultaneously using pneumotachography and structured light plethysmography , 2017, Physiological reports.

[25]  Expert Panel Report 3 (EPR-3): Guidelines for the Diagnosis and Management of Asthma-Summary Report 2007. , 2007, The Journal of allergy and clinical immunology.

[26]  Janet Stocks,et al.  An official American Thoracic Society/European Respiratory Society statement: pulmonary function testing in preschool children. , 2007, American journal of respiratory and critical care medicine.

[27]  J. Roukema,et al.  Respiratory disease and respiratory physiology: Putting lung function into perspective: Paediatric asthma , 2015, Respirology.

[28]  P. Sly,et al.  Validation of respiratory inductance plethysmography (“Respitrace”®) for the measurement of tidal breathing parameters in newborns , 1992, Pediatric pulmonology.