Least-squares analysis of clock frequency comparison data to deduce optimized frequency and frequency ratio values

A method is presented for analysing over-determined sets of clock frequency comparison data involving standards based on a number of different reference transitions. This least-squares adjustment procedure, which is based on the method used by CODATA to derive a self-consistent set of values for the fundamental physical constants, can be used to derive optimized values for the frequency ratios of all possible pairs of reference transitions. It is demonstrated to reproduce the frequency values recommended by the International Committee for Weights and Measures, when using the same input data used to derive those values. The effects of including more recently published data in the evaluation is discussed and the importance of accounting for correlations between the input data is emphasised.

[1]  P. Rosenbusch,et al.  Experimental realization of an optical second with strontium lattice clocks , 2013, Nature Communications.

[2]  Manoj Das,et al.  Cryogenic optical lattice clocks , 2015, Nature Photonics.

[3]  Tobias Wilken,et al.  Precision measurement of the hydrogen 1S-2S frequency via a 920-km fiber link. , 2013, Physical review letters.

[4]  E. Peik,et al.  Improved limit on a temporal variation of mp/me from comparisons of Yb+ and Cs atomic clocks. , 2014, Physical review letters.

[5]  Mizuhiko Hosokawa,et al.  Direct comparison of a Ca+ single-ion clock against a Sr lattice clock to verify the absolute frequency measurement. , 2012, Optics express.

[6]  Tomonari Suzuyama,et al.  Spectroscopy and frequency measurement of the 87Sr clock transition by laser linewidth transfer using an optical frequency comb , 2014, 1401.1008.

[7]  Davide Calonico,et al.  IEN-CsF1 primary frequency standard at INRIM: accuracy evaluation and TAI calibrations , 2006 .

[8]  Dai-Hyuk Yu,et al.  Absolute frequency measurement of 1S0 (F = 1/2) - 3P0 (F = 1/2) transition of 171Yb atoms in a one-dimensional optical lattice at KRISS , 2011 .

[9]  Patrick Gill,et al.  Agreement between two 88 Sr + optical clocks to 4 parts in 10 17 , 2014 .

[10]  Vladislav Gerginov,et al.  A strontium lattice clock with 3 × 10 − 17 ?> inaccuracy and its frequency , 2013, 1312.3419.

[11]  J. Guéna,et al.  Progress in atomic fountains at LNE-SYRTE , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  D. Piester,et al.  International timescales with optical clocks (ITOC) , 2013, 2013 Joint European Frequency and Time Forum & International Frequency Control Symposium (EFTF/IFC).

[13]  K. Gibble,et al.  Distributed cavity phase frequency shifts of the caesium fountain PTB-CSF2 , 2011, 1110.2590.

[14]  Jon H. Shirley,et al.  First accuracy evaluation of NIST-F2 , 2014 .

[15]  D. Wineland,et al.  Frequency comparison of two high-accuracy Al+ optical clocks. , 2009, Physical review letters.

[16]  Feng-Lei Hong,et al.  Frequency ratio measurement of 171Yb and 87Sr optical lattice clocks. , 2014, Optics express.

[17]  T L Nicholson,et al.  Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty , 2014, Nature Communications.

[18]  D. Wineland,et al.  Frequency Ratio of Al+ and Hg+ Single-Ion Optical Clocks; Metrology at the 17th Decimal Place , 2008, Science.

[19]  E. Peik,et al.  Cs-based optical frequency measurement using cross-linked optical and microwave oscillators , 2013, 1310.8190.

[20]  Peter J. Mohr,et al.  CODATA Recommended Values of the Fundamental Constants: 1998 , 2000 .

[21]  Patrick Gill,et al.  When should we change the definition of the second? , 2011, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[22]  A. Ludlow,et al.  An Atomic Clock with 10–18 Instability , 2013, Science.

[23]  Wei Zhang,et al.  An optical lattice clock with accuracy and stability at the 10−18 level , 2013, Nature.

[24]  Marco Pizzocaro,et al.  An Atomic Clock with 10–¹⁸ Instability , 2013 .

[25]  P Gill,et al.  Frequency ratio of two optical clock transitions in 171Yb+ and constraints on the time variation of fundamental constants. , 2014, Physical review letters.

[26]  S. Lea,et al.  An evaluation of the frequency shift caused by collisions with background gas in the primary frequency standard NPL-CsF2 , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.