Detection of harmful metallic particles inside gas insulated switchgear using UHF sensor

Gas insulated switchgears (GIS) are widely used as major substation equipment because of their excellent insulation and interruption performance. However, while a GIS is highly reliable, it is a concealed device, meaning diagnostic technology using various sensors is required to detect any insulation abnormality. Among various potential defects inside a GIS, the most problematic is caused by the existence of fine metallic particles, and thus the ability to detect harmful particles in tests at a factory and on site as well as in operation is becoming an important subject. This paper examines, on an experimental basis, the UHF sensor's characteristics of detecting partial discharge (PD) signals generated from particles inside the GIS with those placed freely on the bottom surface of the tank, having adhered to the insulating spacer's surface, and fixed on the center conductor, respectively. Based on previous reports, breakdown characteristics with the existence of particles were arranged in terms of the particle length, and the harmful particle length was estimated. Both results were compared with each other to evaluate the possibility of detecting harmful particles in each location with the UHF sensor. Consequently, it emerged that free particles were detected comparatively easily. However, while those having adhered to the spacer's surface and fixed on the center conductor could be detected in insulation tests at 2 pu at a factory, detection was difficult in many cases in the field.

[1]  Investigation of high-voltage particle-initiated breakdown in gas-insulated systems. Final report , 1979 .

[2]  T. Yamagiwa,et al.  Particle-Initiated Breakdown Characteristics and Reliability Improvement in SF6 Gas Insulation , 1986, IEEE Transactions on Power Delivery.

[3]  T. Yamagiwa,et al.  Particle-Initiated Breakdown Characteristics and Reliability Improvement in SF6 Gas Insulation , 1986, IEEE Transactions on Power Delivery.

[4]  H. Aoyagi,et al.  A study on effects of conducting particles in SF/sub 6/ gas and test methods for GIS , 1988 .

[5]  S. Okabe,et al.  Voltage-time characteristics for steep-front impulse voltages of particle-contaminated spacers in SF/sub 6/ gas-insulated switchgear , 1992 .

[6]  L.E. Lundgaard,et al.  Partial discharge. XIV. Acoustic partial discharge detection-practical application , 1992, IEEE Electrical Insulation Magazine.

[7]  B. F. Hampton,et al.  The excitation of UHF signals by partial discharges in GIS , 1996 .

[8]  W. Boeck Insulation Co-Ordination of GIS, Return of Experience, On Site Tests and Diagnostic Techniques , 1998 .

[9]  Anthony Vetro,et al.  Minimum drift architectures for 3-layer scalable DTV decoding , 1998 .

[10]  Andrew R. Hileman Metal Oxide Surge Arresters , 1999 .

[11]  W. Boeck,et al.  Partial Discharge Detection Systems for GIS: Sensitivity Verification for the UHF Method and the Acoustic Method , 1999 .

[12]  Tatsuro Kato,et al.  Development of UHF Insulation Diagnosis System of GIS , 1999 .

[13]  U. Schichler,et al.  UHF PD detection in GIS substations during on-site testing , 2000 .

[14]  N. Hayakawa,et al.  Power frequency dependence of space charge behavior and partial discharge characteristics in SF/sub 6/ gas , 2000 .