A New Multilevel Ground Water Monitoring System Using Multichannel Tubing

A new multilevel ground water monitoring system has been developed that uses custom-extruded flexible 1.6-inch (4.1 cm) outside-diameter (O.D.) multichannel HDPE tubing (referred to as Continuous Multichannel Tubing™ or CMT) to monitor as many as seven discrete zones within a single borehole in either unconsolidated sediments or bedrock. Prior to inserting the tubing in the borehole, ports are created that allow ground water to enter six outer pie-shaped channels (nominal diameter = 0.5 inch [1.3 cm]) and a central hexagonal center channel (nominal diameter = 0.4 inch [1 cm]) at different depths, facilitating the measurement of depth-discrete piezometric heads and the collection of depth-discrete ground water samples. Sand packs and annular seals between the various monitored zones can be installed using conventional tremie methods. Alternatively, bentonite packers and prepacked sand packs have been developed that are attached to the tubing at the ground surface, facilitating precise positioning of annular seals and sand packs. Inflatable rubber packers for permanent or temporary installations in bedrock aquifers are currently undergoing site trials. Hydraulic heads are measured with conventional water-level meters or electronic pressure transducers to generate vertical profiles of hydraulic head. Ground water samples are collected using peristaltic pumps, small-diameter bailers, inertial lift pumps, or small-diameter canister samplers. For monitoring hydrophobic organic compounds, the CMT tubing is susceptible to both positive and negative biases caused by sorption, desorption, and diffusion. These biases can be minimized by: (1) purging the channels prior to sampling, (2) collecting samples from separate 0.25-inch (0.64 cm) O.D. Teflon® sampling tubing inserted to the bottom of each sampling channel, or (3) collecting the samples downhole using sampling devices positioned next to the intake ports. More than 1000 CMT multilevel wells have been installed in North America and Europe to depths up to 260 feet (79 m) below ground surface. These wells have been installed in boreholes created in unconsolidated sediments and bedrock using a wide range of drilling equipment, including sonic, air rotary, diamond-bit coring, hollow-stem auger, and direct push. This paper presents a discussion of three field trials of the system, demonstrating its versatility and illustrating the type of depth-discrete data that can be collected with the system.

[1]  Thomas A. Ranney,et al.  Sampling trace-level organic solutes with polymeric tubing. Part 2: Dynamic studies , 1997 .

[2]  M. Celia,et al.  Large-scale natural gradient tracer test in sand and gravel, Cape Cod, Massachusetts, 2, Analysis of spatial moments for a nonreactive tracer , 1991 .

[3]  Gary A. Robbins,et al.  Mass balance evaluation of monitoring well purging: Part I. Theoretical models and implications for representative sampling , 1991 .

[4]  Robert W. Gillham,et al.  Sorption of Aromatic Hydrocarbons by Materials Used in Construction of Ground-Water Sampling Wells , 1990 .

[5]  Louise V. Parker,et al.  The Effects of Ground Water Sampling Devices on Water Quality: A Literature Review , 1994 .

[6]  Gregor A. Junk,et al.  Contamination of water by synthetic polymer tubes , 1974 .

[7]  John A. Cherry,et al.  Design of a Ground-Water Sampler for Collecting Volatile Organics and Dissolved Gases in Small-Diameter Wellsa , 1987 .

[8]  F H Snow UNIVERSITY OF KANSAS STATE GEOLOGICAL SURVEY. , 1895, Science.

[9]  W. W. Wood,et al.  Large-Scale Natural Gradient Tracer Test in Sand and Gravel, , 1991 .

[10]  John A. Cherry,et al.  Migration of contaminants in groundwater at a landfill: A case study: 1. Groundwater flow and plume delineation , 1983 .

[11]  Yadu B. Tewari,et al.  Aqueous solubility and octanol/water partition coefficient of organic compounds at 25.0.degree.C , 1982 .

[12]  James F. Barker,et al.  Some Biases in Sampling Multilevel Piezometers for Volatile Organics , 1987 .

[13]  John A. Cherry,et al.  Migration of contaminants in groundwater at a landfill: A case study: 4. A natural-gradient dispersion test , 1983 .

[14]  R. Schwarzenbach,et al.  Environmental Organic Chemistry , 1993 .

[15]  John A. Cherry,et al.  Field Study of a Long and Very Narrow Contaminant Plume , 1994 .

[16]  Gary A. Robbins,et al.  Influence of Using Purged and Partially Penetrating Monitoring Wells on Contaminant Detection, Mapping, and Modeling , 1989 .

[17]  W. F. Merritt,et al.  A Multilevel Device for Ground‐Water Sampling and Piezometric Monitoring , 1978 .

[18]  Thomas A. Ranney,et al.  Sampling Trace-Level Organics with Polymeric Tubings. , 1996 .

[19]  Alan D. Hewitt,et al.  Dynamic Study of Common Well Screen Materials , 1993 .

[20]  John A. Cherry,et al.  A Tube and Cartridge Method for Down‐Hole Sampling for Trace Organic Compounds in Ground Water , 1985 .

[21]  Gary A. Robbins,et al.  Mass balance evaluation of monitoring well purging: Part II. Field tests at a gasoline contamination site , 1991 .

[22]  Thomas A. Ranney,et al.  Comparison of Fiberglass and Other Polymeric Well Casings, Part III. Sorption and Leaching of Trace‐Level Metals , 1998 .

[23]  John A. Cherry,et al.  A MULITILEVEL DEVICE FOR MONITORING IN FRACTURED ROCK , 1982 .

[24]  William P. Ball,et al.  Variability of aquifer sorption properties in a field experiment on groundwater transport of organic solutes: Methods and preliminary results , 1986 .

[25]  M. Barcelona,et al.  Sampling tubing effects on groundwater samples , 1985 .

[26]  E. H. Ronnie,et al.  An Inexpensive, Multi‐Use, Dedicated Pump for Ground Water Monitoring Wells , 1988 .

[27]  Alan D. Hewitt,et al.  Influence of Casing Materials on Trace‐Level Chemicals in Well Water , 1990 .

[28]  Gary R. Olhoeft,et al.  Observed Migration of a Controlled DNAPL Release by Geophysical Methods , 1995 .

[29]  Alan D. Hewitt,et al.  Potential of Common Well Casing Materials to Influence Aqueous Metal Concentrations , 1992 .

[30]  John A. Cherry,et al.  Ground‐Water Contamination from Two Small Septic Systems on Sand Aquifers , 1991 .

[31]  J. Barrow,et al.  The Resonant Sonic Drilling Method: An Innovative Technology for Environmental Restoration Programs , 1994 .

[32]  Mason B. Tomson,et al.  LEACHING OF TRACE ORGANICS INTO WATER FROM FIVE COMMON PLASTICS , 1983 .

[33]  Stephanie Fiorenza,et al.  Sequenced Reactive Barriers for Groundwater Remediation , 1999 .

[34]  D. Freyberg,et al.  A natural gradient experiment on solute transport in a sand aquifer: 1. Approach and overview of plume movement , 1986 .

[35]  John A. Cherry,et al.  A Syringe and Cartridge Method for Down‐Hole Sampling for Trace Organics in Ground Water , 1984 .

[36]  Martin Reinhard,et al.  Occurrence and distribution of organic chemicals in two landfill leachate plumes , 1984 .