Electrical impedance tomography: changes in distribution of pulmonary ventilation during laparoscopic surgery in a porcine model

BackgroundBecause of the creation of a pneumoperitoneum, impairment of ventilation is a common side-effect during laparoscopic surgery. Electrical impedance tomography (EIT) is a method with the potential for becoming a tool to quantify these alterations during surgery. We have studied the change of regional ventilation during and after laparoscopic surgery with EIT and compared the diagnostic findings with computed tomography (CT) scans in a porcine study.Materials and methodsAfter approval by the local animal ethics committee, six pigs were included in the study. Two laparoscopic operations were performed [colon resection (n=3) and fundoplicatio (n=3)]. The EIT measurements (6th parasternal intercostal space) were continuously recorded by an EIT prototype (EIT Evaluation Kit, Dräger Medical, Lübeck, Germany). To verify ventilatory alterations detected by EIT, a CT scan was performed postoperatively.ResultsVentilation with defined tidal volumes was significantly correlated to EIT measurements (r2=0.99). After creation of the pneumoperitoneum, lung compliance typically decreased, which agreed well with an alteration of the distribution of pulmonary ventilation measured by EIT. Elevation of positive end-inspiratory pressure reopened non-aerated lung areas and showed a recovery of the regional ventilation measured by EIT. Additionally, we could detect pulmonary complications by EIT monitoring as verified by CT scans postoperatively.ConclusionEIT monitoring can be used as a continuous non-invasive intraoperative monitor of ventilation to detect regional changes of ventilation and pulmonary complications during laparoscopic surgery. These EIT findings indicate that surgeons and anesthetists may eventually be able to optimize ventilation directly in the operating theatre.

[1]  Burkhard Lachmann,et al.  Monitoring of recruitment and derecruitment by electrical impedance tomography in a model of acute lung injury , 2000, Critical care medicine.

[2]  Harki Tanaka,et al.  Imbalances in regional lung ventilation: a validation study on electrical impedance tomography. , 2004, American journal of respiratory and critical care medicine.

[3]  B. Wolfe,et al.  The Physiologic Effects of Pneumoperitoneum in the Morbidly Obese , 2005, Annals of surgery.

[4]  J C Newell,et al.  Real-time three-dimensional electrical impedance imaging. , 2000, Physiological measurement.

[5]  G Hahn,et al.  Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography , 1998, Acta anaesthesiologica Scandinavica.

[6]  R. Brandstetter,et al.  Laparoscopic surgery and its potential for medical complications. , 1997, Heart & lung : the journal of critical care.

[7]  P. Aspelin,et al.  Effect of Carbon Dioxide Pneumoperitoneum on Development of Atelectasis during Anesthesia, Examined by Spiral Computed Tomography , 2005, Anesthesiology.

[8]  D C Barber,et al.  A review of image reconstruction techniques for electrical impedance tomography. , 1989, Medical physics.

[9]  Gerhard Hellige,et al.  Detection of local lung air content by electrical impedance tomography compared with electron beam CT. , 2002, Journal of applied physiology.

[10]  O. Hoekstra,et al.  Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning. , 1998, Physiological measurement.

[11]  R. Brandstetter,et al.  Cardiopulmonary physiology and pathophysiology as a consequence of laparoscopic surgery. , 1996, Chest.

[12]  José Hinz,et al.  Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs. , 2003, Chest.

[13]  A Adler,et al.  Electrical impedance tomography can monitor dynamic hyperinflation in dogs. , 1998, Journal of applied physiology.

[14]  J. Jansen,et al.  Estimation of regional lung volume changes by electrical impedance pressures tomography during a pressure-volume maneuver , 2003, Intensive Care Medicine.

[15]  A Adler,et al.  Monitoring changes in lung air and liquid volumes with electrical impedance tomography. , 1997, Journal of applied physiology.

[16]  Gerhard Hellige,et al.  Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure , 1999, IEEE Transactions on Medical Imaging.

[17]  John H Arnold,et al.  Noninvasive assessment of lung volume: Respiratory inductance plethysmography and electrical impedance tomography , 2005, Critical care medicine.

[18]  J. Chiche,et al.  Pneumothorax During Laparoscopic Fundoplication: Diagnosis and Treatment with Positive End-Expiratory Pressure , 1995, Anesthesia and analgesia.

[19]  T Schröder,et al.  A simple method to check the dynamic performance of electrical impedance tomography systems. , 2000, Physiological measurement.

[20]  T. Oniu,et al.  Circulatory and Respiratory Complications of Carbon Dioxide Insufflation , 2004, Digestive Surgery.

[21]  B H Brown,et al.  Electrical impedance tomography (EIT): a review , 2003, Journal of medical engineering & technology.