Wearable Piezoelectric-Based System for Continuous Beat-to-Beat Blood Pressure Measurement

Non-invasive continuous blood pressure measurement is an emerging issue that potentially can be applied to cardiovascular disease monitoring and prediction. Recently, many groups have proposed the pulse transition time (PTT) method to estimate blood pressure for long-term monitoring. However, the PTT-based methods for blood pressure estimation are limited by non-specific estimation models and require multiple calibrations. This study aims to develop a low-cost wearable piezoelectric-based system for continuous beat-to-beat blood pressure measurement. The pressure change in the radial artery was extracted by systolic and diastolic feature points in pressure pulse wave (PPW) and the pressure sensitivity of the sensor. The proposed system showed a reliable accuracy of systolic blood pressure (SBP) (mean absolute error (MAE) ± standard deviation (SD) 1.52 ± 0.30 mmHg) and diastolic blood pressure (DBP, MAE ± SD 1.83 ± 0.50), and its performance agreed with standard criteria of MAE within 5 mmHg and SD within ±8 mmHg. In conclusion, this study successfully developed a low-cost, high-accuracy piezoelectric-based system for continuous beat-to-beat SBP and DBP measurement without multiple calibrations and complex regression analysis. The system is potentially suitable for continuous, long-term blood pressure-monitoring applications.

[1]  X. Aubert,et al.  Is pulse transit time a good indicator of blood pressure changes during short physical exercise in a young population? , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[2]  A S Berson,et al.  National Standard for Measurement of Resting and Ambulatory Blood Pressures With Automated Sphygmomanometers , 1993, Hypertension.

[3]  Ramon Pallàs-Areny,et al.  AC-coupled front-end for biopotential measurements , 2003, IEEE Transactions on Biomedical Engineering.

[4]  M. Masè,et al.  Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure. , 2011, Journal of electrocardiology.

[5]  Mitja Lustrek,et al.  Blood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network , 2019, Sensors.

[6]  Qiao Zhang,et al.  Noninvasive cuffless blood pressure estimation using pulse transit time and Hilbert-Huang transform , 2013, Comput. Electr. Eng..

[7]  Haiyan Wu,et al.  A Non-Invasive Continuous Blood Pressure Estimation Approach Based on Machine Learning , 2019, Sensors.

[8]  J. Kitterman,et al.  Catheterization of umbilical vessels in newborn infants. , 1970, Pediatric clinics of North America.

[9]  E. Nye,et al.  THE EFFECT OF BLOOD PRESSURE ALTERATION ON THE PULSE WAVE VELOCITY , 1964, British heart journal.

[10]  Yu-Jen Wang,et al.  Estimation of Blood Pressure in the Radial Artery Using Strain-Based Pulse Wave and Photoplethysmography Sensors , 2018, Micromachines.

[11]  Michelle Khine,et al.  Soft Wearable Pressure Sensors for Beat‐to‐Beat Blood Pressure Monitoring , 2019, Advanced healthcare materials.

[12]  Guy D. Dumont,et al.  Continuous noninvasive blood pressure measurement by pulse transit time , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  Onur Toker,et al.  Design of a Portable Electromyography Device for Back Herniated Patients , 2010, BIODEVICES.

[14]  Norbert Noury,et al.  A review of methods for non-invasive and continuous blood pressure monitoring: Pulse transit time method is promising? , 2014 .

[15]  Shing-Hong Liu,et al.  A Cuffless Blood Pressure Measurement Based on the Impedance Plethysmography Technique , 2017, Sensors.

[16]  Tzung K. Hsiai,et al.  Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review , 2017 .

[17]  A. Steptoe,et al.  Pulse wave velocity as a measure of blood pressure change. , 1976, Psychophysiology.

[18]  F. Mee,et al.  Evaluation of blood pressure measuring devices. , 1993, Clinical and experimental hypertension.

[19]  Pekka Kostiainen,et al.  Clinical assessment of a non-invasive wearable MEMS pressure sensor array for monitoring of arterial pulse waveform, heart rate and detection of atrial fibrillation , 2019, npj Digital Medicine.

[20]  T. Togawa,et al.  Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration , 2000, Medical and Biological Engineering and Computing.

[21]  Bo Wen,et al.  Cuffless Blood Pressure Estimation Using Pressure Pulse Wave Signals , 2018, Sensors.

[22]  Carmen C. Y. Poon,et al.  An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive Subjects , 2009, Cardiovascular engineering.

[23]  Matjaz Gams,et al.  Non-Invasive Blood Pressure Estimation from ECG Using Machine Learning Techniques , 2018, Sensors.

[24]  Guy Carrault,et al.  A New Wearable Device for Blood Pressure Estimation Using Photoplethysmogram , 2019, Sensors.

[25]  Surendhra Goli,et al.  Cuff less Continuous Non-Invasive Blood Pressure Measurement Using Pulse Transit Time Measurement , 2014 .