Experimental study of cooling BIPV modules by forced convection in the air channel

The efficiency of photovoltaic systems depends mainly on the cell temperature. Frequently, the PV collectors are installed on the top of the building. One cost effective method to regulate the temperature of rooftop integrated photovoltaic panels is to provide an open air channel beneath the panel. The cell temperature of these PV modules is very much influenced by the capability of ventilating this channel. The ventilation may be modified by different factors such as the wind velocity, the air gap size, and the forced convection induced by a fan or by a conventional air conditioning system. This paper describes an experimental setup to study the influence of the air gap size and the forced ventilation on the cell temperature (and consequently on the electrical efficiency of the PV module) of a BIPV configuration, for different values of the incident solar radiation, ambient temperatures, and aspect ratios, as well as for several forced ventilation conditions. Semi empirical correlations for the Ross coefficient, module temperature, electrical efficiency, and power output are proposed, showing a good agreement with respect to experimental measurements. A critical channel aspect ratio close to 0.11 can be considered to minimize overheating of PV devices. For a duct velocity Vv=6m/s, a power output increase of 19% is observed over the natural ventilation case (Vv=0.5m/s).

[1]  Joseph Khedari,et al.  Field measurements of performance of roof solar collector , 2000 .

[2]  D. L. Evans,et al.  Cost studies on terrestrial photovoltaic power systems with sunlight concentration , 1977 .

[3]  Wenyuan Li,et al.  Reliability assessment of photovoltaic power systems: Review of current status and future perspectives , 2013 .

[4]  Tin-Tai Chow,et al.  A Review on Photovoltaic/Thermal Hybrid Solar Technology , 2010, Renewable Energy.

[5]  Guohui Gan,et al.  Numerical determination of adequate air gaps for building-integrated photovoltaics , 2009 .

[6]  Barry N. Taylor,et al.  Guidelines for Evaluating and Expressing the Uncertainty of Nist Measurement Results , 2017 .

[7]  Stas Burek,et al.  Experimental study of the influence of collector height on the steady state performance of a passive solar air heater , 2010 .

[8]  R. G. Ross,et al.  Interface design considerations for terrestrial solar cell modules , 1976 .

[9]  J. Palyvos A survey of wind convection coefficient correlations for building envelope energy systems’ modeling , 2008 .

[10]  Mats Sandberg,et al.  Buoyancy-induced air flow in photovoltaic facades: Effect of geometry of the air gap and location of solar cell modules , 2002 .

[11]  E. Skoplaki,et al.  A simple correlation for the operating temperature of photovoltaic modules of arbitrary mounting , 2008 .

[12]  Zahari Ibarahim,et al.  A validated model of naturally ventilated PV cladding , 2000 .

[13]  Ji Jie,et al.  Modeling of a novel Trombe wall with PV cells , 2007 .

[14]  Joseph Khedari,et al.  Experimental study of a roof solar collector towards the natural ventilation of new houses , 1997 .

[15]  D. Loveday,et al.  Convective heat transfer coefficients at a plane surface on a full-scale building facade , 1996 .

[16]  T. Nordmann,et al.  Understanding temperature effects on PV system performance , 2003, 3rd World Conference onPhotovoltaic Energy Conversion, 2003. Proceedings of.

[17]  Andreas K. Athienitis,et al.  Modeling of energy performance of a house with three configurations of building-integrated photovoltaic/thermal systems , 2010 .