Stochastic Modeling Based Nonlinear Bayesian Filtering for Photoplethysmography Denoising in Wearable Devices
暂无分享,去创建一个
Wei Chen | Chenyun Dai | Xinyu Jiang | Sijie Lin | Ke Xu | Wei Chen | C. Dai | Ke Xu | Xinyu Jiang | Sijie Lin
[1] Wei Chen,et al. Deep Recurrent Neural Network for Extracting Pulse Rate Variability from Photoplethysmography During Strenuous Physical Exercise , 2019, 2019 IEEE Biomedical Circuits and Systems Conference (BioCAS).
[2] Bahram Tarvirdizadeh,et al. A novel online method for identifying motion artifact and photoplethysmography signal reconstruction using artificial neural networks and adaptive neuro-fuzzy inference system , 2018, Neural Computing and Applications.
[3] Andriy Temko,et al. Accurate Heart Rate Monitoring During Physical Exercises Using PPG , 2017, IEEE Transactions on Biomedical Engineering.
[4] Zhilin Zhang,et al. Photoplethysmography-Based Heart Rate Monitoring Using Asymmetric Least Squares Spectrum Subtraction and Bayesian Decision Theory , 2015, IEEE Sensors Journal.
[5] Md. Kamrul Hasan,et al. A Robust Heart Rate Monitoring Scheme Using Photoplethysmographic Signals Corrupted by Intense Motion Artifacts , 2016, IEEE Transactions on Biomedical Engineering.
[6] Jürgen Schmidhuber,et al. Framewise phoneme classification with bidirectional LSTM and other neural network architectures , 2005, Neural Networks.
[7] Survi Kyal,et al. Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice , 2015, IEEE Transactions on Biomedical Engineering.
[8] Jinseok Lee,et al. Finite State Machine Framework for Instantaneous Heart Rate Validation Using Wearable Photoplethysmography During Intensive Exercise , 2019, IEEE Journal of Biomedical and Health Informatics.
[9] Wei Chen,et al. Photoplethysmography Motion Artifacts Removal Based on Signal-Noise Interaction Modeling Utilizing Envelope Filtering and Time-Delay Neural Network , 2020, IEEE Sensors Journal.
[10] E. Hari Krishna,et al. A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter , 2012, IEEE Transactions on Instrumentation and Measurement.
[11] Dwaipayan Biswas,et al. Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review , 2019, IEEE Sensors Journal.
[12] H. Lee,et al. Motion Artifact Cancellation in Wearable Photoplethysmography Using Gyroscope , 2019, IEEE Sensors Journal.
[13] Zhilin Zhang,et al. Combining Nonlinear Adaptive Filtering and Signal Decomposition for Motion Artifact Removal in Wearable Photoplethysmography , 2016, IEEE Sensors Journal.
[14] Ronald M. Aarts,et al. Reduction of Periodic Motion Artifacts in Photoplethysmography , 2017, IEEE Transactions on Biomedical Engineering.
[15] Purbadri Ghosal,et al. Classification of photoplethysmogram signal using self organizing map , 2015, 2015 IEEE International Conference on Research in Computational Intelligence and Communication Networks (ICRCICN).
[16] Farrokh Marvasti,et al. Heart Rate Tracking using Wrist-Type Photoplethysmographic (PPG) Signals during Physical Exercise with Simultaneous Accelerometry , 2015, IEEE Signal Processing Letters.
[17] Christian Jutten,et al. A Nonlinear Bayesian Filtering Framework for ECG Denoising , 2007, IEEE Transactions on Biomedical Engineering.
[18] Jo Woon Chong,et al. A Robust Motion Artifact Detection Algorithm for Accurate Detection of Heart Rates From Photoplethysmographic Signals Using Time–Frequency Spectral Features , 2017, IEEE Journal of Biomedical and Health Informatics.
[19] Toshiyo Tamura,et al. Relationship Between Measurement Site and Motion Artifacts in Wearable Reflected Photoplethysmography , 2011, Journal of Medical Systems.
[20] Cinna Soltanpur,et al. A review on wearable photoplethysmography sensors and their potential future applications in health care , 2018, International journal of biosensors & bioelectronics.
[21] S. M. A. Salehizadeh,et al. OxiMA: A Frequency-Domain Approach to Address Motion Artifacts in Photoplethysmograms for Improved Estimation of Arterial Oxygen Saturation and Pulse Rate , 2019, IEEE Transactions on Biomedical Engineering.
[22] Boreom Lee,et al. Improved elimination of motion artifacts from a photoplethysmographic signal using a Kalman smoother with simultaneous accelerometry , 2010, Physiological measurement.
[23] Sunho Kim,et al. Characterization of Quadratic Nonlinearity between Motion Artifact and Acceleration Data and its Application to Heartbeat Rate Estimation , 2017, Sensors.
[24] Nicola Toschi,et al. Non-Invasive Detection of Mechanical Alternans Utilizing Photoplethysmography , 2019, IEEE Journal of Biomedical and Health Informatics.
[25] Suiren Wan,et al. SFST: A robust framework for heart rate monitoring from photoplethysmography signals during physical activities , 2017, Biomed. Signal Process. Control..
[26] John Allen. Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.
[27] E. Hari Krishna,et al. ICA-Based Improved DTCWT Technique for MA Reduction in PPG Signals With Restored Respiratory Information , 2013, IEEE Transactions on Instrumentation and Measurement.
[28] Rajarshi Gupta,et al. Improving Photoplethysmographic Measurements Under Motion Artifacts Using Artificial Neural Network for Personal Healthcare , 2018, IEEE Transactions on Instrumentation and Measurement.
[29] Sayeed Shafayet Chowdhury,et al. Real-Time Robust Heart Rate Estimation From Wrist-Type PPG Signals Using Multiple Reference Adaptive Noise Cancellation , 2018, IEEE Journal of Biomedical and Health Informatics.
[30] Chris Van Hoof,et al. Motion Artifact Reduction for Wrist-Worn Photoplethysmograph Sensors Based on Different Wavelengths , 2019, Sensors.
[31] Mario Konijnenburg,et al. CorNET: Deep Learning Framework for PPG-Based Heart Rate Estimation and Biometric Identification in Ambulant Environment , 2019, IEEE Transactions on Biomedical Circuits and Systems.
[32] Pablo Casaseca-de-la-Higuera,et al. Stochastic Modeling of the PPG Signal: A Synthesis-by-Analysis Approach With Applications , 2013, IEEE Transactions on Biomedical Engineering.
[33] David A. Clifton,et al. Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review , 2017, IEEE Reviews in Biomedical Engineering.
[34] Zhilin Zhang,et al. A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts , 2017, Sensors.
[35] Hee Chan Kim,et al. Bidirectional Recurrent Auto-Encoder for Photoplethysmogram Denoising , 2019, IEEE Journal of Biomedical and Health Informatics.
[36] Ki H. Chon,et al. A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor , 2015, Sensors.
[37] Sun K. Yoo,et al. Motion artifact reduction in photoplethysmography using independent component analysis , 2006, IEEE Transactions on Biomedical Engineering.
[38] U. Rajendra Acharya,et al. Heart rate variability: a review , 2006, Medical and Biological Engineering and Computing.