Correction of concomitant gradient artifacts in experimental microtesla MRI.

Magnetic resonance imaging (MRI) suffers from artifacts caused by concomitant gradients when the product of the magnetic field gradient and the dimension of the sample becomes comparable to the static magnetic field. To investigate and correct for these artifacts at very low magnetic fields, we have acquired MR images of a 165-mm phantom in a 66-microT field using gradients up to 350 microT/m. We prepolarize the protons in a field of about 100 mT, apply a spin-echo pulse sequence, and detect the precessing spins using a superconducting gradiometer coupled to a superconducting quantum interference device (SQUID). Distortion and blurring are readily apparent at the edges of the images; by comparing the experimental images to computer simulations, we show that concomitant gradients cause these artifacts. We develop a non-perturbative, post-acquisition phase correction algorithm that eliminates the effects of concomitant gradients in both the simulated and the experimental images. This algorithm assumes that the switching time of the phase-encoding gradient is long compared to the spin precession period. In a second technique, we demonstrate that raising the precession field during phase encoding can also eliminate blurring caused by concomitant phase-encoding gradients; this technique enables one to correct concomitant gradient artifacts even when the detector has a restricted bandwidth that sets an upper limit on the precession frequency. In particular, the combination of phase correction and precession field cycling should allow one to add MRI capabilities to existing 300-channel SQUID systems used to detect neuronal currents in the brain because frequency encoding could be performed within the 1-2 kHz bandwidth of the readout system.

[1]  J. Clarke,et al.  SQUID-Detected Magnetic Resonance Imaging in Microtesla Magnetic Fields , 2004 .

[2]  John S George,et al.  Simultaneous magnetoencephalography and SQUID detected nuclear MR in microtesla magnetic fields , 2004, Magnetic resonance in medicine.

[3]  K F King,et al.  Concomitant gradient field effects in spiral scans , 1999, Magnetic resonance in medicine.

[4]  John Clarke,et al.  Low field magnetic resonance images of polarized noble gases obtained with a dc superconducting quantum interference device , 1998 .

[5]  D G Cory,et al.  Low-field MRI of laser polarized noble gas. , 1998, Physical review letters.

[6]  M. Hatridge,et al.  SQUID-detected in vivo MRI at microtesla magnetic fields , 2005, IEEE Transactions on Applied Superconductivity.

[7]  N J Pelc,et al.  Concomitant gradient terms in phase contrast MR: Analysis and correction , 1998, Magnetic resonance in medicine.

[8]  J. Hutchison,et al.  Gradiometer pick-up coil design for a low field SQUID-MRI system , 1999, Magnetic Resonance Materials in Physics, Biology and Medicine.

[9]  Albert Macovski,et al.  Homogeneous magnet design using linear programming , 2000 .

[10]  P A Rinck,et al.  Nuclear relaxation of human brain gray and white matter: Analysis of field dependence and implications for MRI , 1990, Magnetic resonance in medicine.

[11]  Ferenc A Jolesz,et al.  MRI of the lung gas-space at very low-field using hyperpolarized noble gases. , 2003, Magnetic resonance imaging.

[12]  Christopher P Bidinosti,et al.  In vivo NMR of hyperpolarized 3He in the human lung at very low magnetic fields. , 2002, Journal of magnetic resonance.

[13]  John Clarke,et al.  SQUID‐detected MRI at 132 μT with T1‐weighted contrast established at 10 μT–300 mT , 2005 .

[14]  A. Sukstanskii,et al.  Image artifacts in very low magnetic field MRI: the role of concomitant gradients. , 2005, Journal of magnetic resonance.

[15]  Yu-Chung N. Cheng,et al.  Magnetic Resonance Imaging: Physical Principles and Sequence Design , 1999 .

[16]  P L Volegov,et al.  On concomitant gradients in low-field MRI. , 2005, Journal of magnetic resonance.

[17]  Miss A.O. Penney (b) , 1974, The New Yale Book of Quotations.

[18]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[19]  John S George,et al.  SQUID detected NMR in microtesla magnetic fields. , 2004, Journal of magnetic resonance (San Diego, Calif. 1997 : Print).

[20]  J M Hutchison,et al.  Concomitant magnetic field gradients and their effects on imaging at low magnetic field strengths. , 1990, Magnetic resonance imaging.

[21]  Dimitris Sakellariou,et al.  Zero- to low-field MRI with averaging of concomitant gradient fields. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[22]  R M Weisskoff,et al.  Nonaxial whole‐body instant imaging , 1993, Magnetic resonance in medicine.

[23]  G. Topulos,et al.  3He lung imaging in an open access, very‐low‐field human magnetic resonance imaging system , 2005, Magnetic resonance in medicine.

[24]  Yiping P. Du,et al.  Correction of concomitant magnetic field‐induced image artifacts in nonaxial echo‐planar imaging , 2002, Magnetic resonance in medicine.

[25]  Robert McDermott,et al.  Microtesla MRI with a superconducting quantum interference device. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[26]  MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT) , 2004, Magnetic Resonance Materials in Physics, Biology and Medicine.

[27]  Gorazd Planinsic,et al.  Relaxation-time measurement and imaging in the earth's magnetic field , 1994 .

[28]  A Macovski,et al.  A readout magnet for prepolarized MRI , 1996, Magnetic resonance in medicine.

[29]  M A Bernstein,et al.  Concomitant magnetic‐field‐induced artifacts in axial echo planar imaging , 1998, Magnetic resonance in medicine.