Optimizing inter-session reliability of heart rate variability - the effects of artefact correction and breathing type.

This study aimed to comprehensively investigate the reliability of multiple heart rate variability (HRV) parameters, and to explore the influence of artefact removal and breathing condition on HRV reliability. Resting HRV was collected using Polar Team monitors on forty-one participants (age: 19.9±1.2 years; 28 females, 13 males) during two separate days. Within each session, participants performed 10 minutes each of spontaneous and controlled breathing (randomized order). Kubios HRV analysis software was used to analyze 180s data epochs using "low" or "strong" artefact removal. Relative reliability was assessed using intraclass correlation coefficients (ICC2,1) and absolute reliability was quantified using mean-normalized standard error of measurement (SEM%). Time domain and nonlinear parameters produced poor to good inter-session agreement (ICC:0.34-0.68; SEM%: 11.0-39.0) with "low" artefact removal, regardless of breathing condition. Frequency domain parameters demonstrated fair inter-session agreement during controlled breathing (ICC:0.40-0.45; SEM%: 26.0-70.0), but poor agreement during spontaneous breathing (ICC:0.07-0.13; SEM%: 32.0-81.0). Minimal differences in ICCs were observed between "low" and "strong" artefact removal. Thus, this study provides three practical applications: 1) HRV monitoring is most reliable when using time domain and nonlinear parameters, regardless of breathing or filtering condition, but no single parameter is especially reliable. The large variation and poor inter-session reliability of frequency indices during spontaneous breathing are improved by controlling breathing rate; 2) "Low" artefact removal appears superior to more aggressive artefact removal; and 3) Inter-session differences in HRV measurements <30% may be indicative of normal daily variation rather than true physiologic changes.

[1]  G. Rodas,et al.  Comparison of Omega Wave System and Polar S810i to Detect R-R Intervals at Rest , 2010, International journal of sports medicine.

[2]  Greg Atkinson,et al.  Monitoring Fatigue During the In-Season Competitive Phase in Elite Soccer Players. , 2015, International journal of sports physiology and performance.

[3]  David Nunan,et al.  Levels of agreement for RR intervals and short-term heart rate variability obtained from the Polar S810 and an alternative system , 2008, European Journal of Applied Physiology.

[4]  Sophia H. Quraishi,et al.  Guidelines for Reporting Articles on Psychiatry and Heart rate variability (GRAPH): recommendations to advance research communication , 2016, PloS one.

[5]  M. Litschmannová,et al.  Intra-session stability of short-term heart rate variability measurement: gender and total spectral power Influence , 2014 .

[6]  Mika P. Tarvainen,et al.  Kubios HRV - Heart rate variability analysis software , 2014, Comput. Methods Programs Biomed..

[7]  Andrew E. Kilding,et al.  Heart rate variability in elite triathletes, is variation in variability the key to effective training? A case comparison , 2012, European Journal of Applied Physiology.

[8]  Barbara Canlon,et al.  Possibilities and limitations of the polar RS800 in measuring heart rate variability at rest , 2011, European Journal of Applied Physiology.

[9]  Eileen Y. Robertson,et al.  Monitoring Athletic Training Status Through Autonomic Heart Rate Regulation: A Systematic Review and Meta-Analysis , 2016, Sports Medicine.

[10]  Andrew E. Kilding,et al.  Training Adaptation and Heart Rate Variability in Elite Endurance Athletes: Opening the Door to Effective Monitoring , 2013, Sports Medicine.

[11]  Christophe Hautier,et al.  The impact of breathing on HRV measurements: Implications for the longitudinal follow-up of athletes , 2013, European journal of sport science.

[12]  Martin Schönfelder,et al.  Scientific Comparison of Different Online Heart Rate Monitoring Systems , 2011, International journal of telemedicine and applications.

[13]  James A. J. Heathers,et al.  Considerations in the assessment of heart rate variability in biobehavioral research , 2014, Front. Psychol..

[14]  G. Millet,et al.  Monitoring Fatigue Status with HRV Measures in Elite Athletes: An Avenue Beyond RMSSD? , 2015, Front. Physiol..

[15]  D. Nunan,et al.  Validity and reliability of short-term heart-rate variability from the Polar S810. , 2009, Medicine and science in sports and exercise.

[16]  M. Buchheit,et al.  Sensitivity of Monthly Heart Rate and Psychometric Measures for Monitoring Physical Performance in Highly Trained Young Handball Players , 2014, International Journal of Sports Medicine.

[17]  C. Hausswirth,et al.  Monitoring training with heart rate-variability: how much compliance is needed for valid assessment? , 2014, International journal of sports physiology and performance.

[18]  A. Flatt,et al.  Heart rate variability stabilization in athletes: towards more convenient data acquisition , 2016, Clinical physiology and functional imaging.

[19]  Laurent Mourot,et al.  Fatigue Shifts and Scatters Heart Rate Variability in Elite Endurance Athletes , 2013, PloS one.

[20]  R. Ritti-Dias,et al.  Intra‐individuals and inter‐ and intra‐observer reliability of short‐term heart rate variability in adolescents , 2016, Clinical physiology and functional imaging.

[21]  R. Maestri,et al.  Heart rate variability measures: a fresh look at reliability. , 2007, Clinical science.

[22]  Matthias Weippert,et al.  Comparison of three mobile devices for measuring R–R intervals and heart rate variability: Polar S810i, Suunto t6 and an ambulatory ECG system , 2010, European Journal of Applied Physiology.

[23]  M. Buchheit Monitoring training status with HR measures: do all roads lead to Rome? , 2014, Front. Physiol..

[24]  A. Aubert,et al.  Heart Rate Variability in Athletes , 2003, Sports medicine.

[25]  F. Nakamura,et al.  The impact of detraining on cardiac autonomic function and specific endurance and muscle power performances of high-level endurance runners. , 2016, The Journal of sports medicine and physical fitness.

[26]  J. Weir Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. , 2005, Journal of strength and conditioning research.

[27]  F. Nakamura,et al.  Daily Monitoring of the Internal Training Load by the Heart Rate Variability : A Case Study , 2017 .

[28]  R. Duffield,et al.  Evidence of disturbed sleep and increased illness in overreached endurance athletes. , 2014, Medicine and science in sports and exercise.

[29]  M. Litschmannová,et al.  Intra-day and inter-day reliability of heart rate variability measurement , 2013, Journal of sports sciences.

[30]  C. Hautier,et al.  The breathing effect of the LF/HF ratio in the heart rate variability measurements of athletes , 2014, European journal of sport science.

[31]  R. Ramírez-Campillo,et al.  Ultra-Short-Term Heart Rate Variability is Sensitive to Training Effects in Team Sports Players. , 2015, Journal of sports science & medicine.

[32]  F. Nakamura,et al.  Intraday and Interday Reliability of Ultra-Short-Term Heart Rate Variability in Rugby Union Players , 2016, Journal of strength and conditioning research.

[33]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.

[34]  D Chollet,et al.  Reliability of Resting and Postexercise Heart Rate Measures , 2011, International journal of sports medicine.

[35]  G. Breithardt,et al.  Heart rate variability: standards of measurement, physiological interpretation and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. , 1996 .

[36]  James A. J. Heathers,et al.  Everything Hertz: methodological issues in short-term frequency-domain HRV , 2014, Front. Physiol..

[37]  J. Thayer,et al.  eview meta-analysis of heart rate variability and neuroimaging studies : Implications or heart rate variability as a marker of stress and health , 2012 .

[38]  G. Billman The LF/HF ratio does not accurately measure cardiac sympatho-vagal balance , 2013, Front. Physio..

[39]  Hannu Kinnunen,et al.  Daily exercise prescription on the basis of HR variability among men and women. , 2010, Medicine and science in sports and exercise.

[40]  Matthias Weippert,et al.  Effects of breathing patterns and light exercise on linear and nonlinear heart rate variability. , 2015, Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme.