A 20µW intra-cardiac signal-processing IC with 82dB bio-impedance measurement dynamic range and analog feature extraction for ventricular fibrillation detection

The accurate recognition of multiple intra-cardiac signals is becoming more and more important for Cardiac Resynchronization Therapy (CRT) and for the analysis of the intra-thoracic fluid status [1, 2]. Robust and accurate Heart-Rate (HR) monitoring at the right/left ventricles and the right atrium is essential for an implantable cardiac pacemaker system (Fig. 16.9.1), and ultra-low power consumption is needed. In addition, an accurate motion sensor and thoracic impedance measurement can acquire valuable additional information in clinical research on the intra-cardiac rhythm analysis. As shown in Fig. 16.9.2, our proposed Analog Signal Processor (ASP) IC consists of 3 power-efficient intra-cardiac signal readout channels. Each channel is equipped with a low-power QRS feature extraction unit and an ECG processor in parallel. The ASP also provides an ultra-low-power readout circuit for an external accelerometer (RA). In addition, two quadrature bio-impedance readout channels are used together with a digitized sinusoidal current generator in order to implement an accurate and wide dynamic range bio-impedance measurement. The ASP improves the state of the art by integrating a power-efficient means of QRS feature extraction for detecting Ventricular Fibrillation (VF), and a wide dynamic range bio-impedance readout.

[1]  Michael Lippert,et al.  Can transventricular intracardiac impedance measurement discriminate haemodynamically unstable ventricular arrhythmias in human? , 2007, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[2]  Seulki Lee,et al.  A 3.9mW 25-electrode reconfigured thoracic impedance/ECG SoC with body-channel transponder , 2010, 2010 IEEE International Solid-State Circuits Conference - (ISSCC).

[3]  Refet Firat Yazicioglu,et al.  Ultra low power wireless ECG system with beat detection and real time impedance measurement , 2010, 2010 Biomedical Circuits and Systems Conference (BioCAS).

[4]  Refet Firat Yazicioglu,et al.  A 30µW Analog Signal Processor ASIC for biomedical signal monitoring , 2010, 2010 IEEE International Solid-State Circuits Conference - (ISSCC).

[5]  A.-T. Avestruz,et al.  A 5 $\mu$ W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine Interfaces , 2008, IEEE Journal of Solid-State Circuits.

[6]  Angelo Auricchio,et al.  Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy , 2007 .