Microfabricated chemical preconcentrators for gas-phase microanalytical detection systems

The gas or vapor preconcentrator is an analytical device that significantly improves the detection limit of a microanalytical system by preconcentrating the analyte. The preconcentrator performs front-end sampling and preconcentration of analyte by collecting and concentrating analyte over a period of time. After the analyte-collection phase is complete, a heat pulse releases the analyte as a concentrated wave into the detector. Desirable features of the preconcentrator device include the capability of operating at high flow rates, thermal heating with short-time constants, and selective collection of the analyte(s) of interest. The preconcentrators presented in this review are used as a generic front-end modification to gas-phase microanalytical detection systems, such as gas chromatographs, mass spectrometers, ion-mobility spectrometers, and microelectromechanical system (MEMS)-based chemical sensors. The advantages of the detector in incorporating a preconcentrator device are enhanced sensitivity and improved selectivity. Target analytes concentrated by the preconcentrators described in this review include various organic compounds in gas or vapor phase, such as explosives 2,4,6-trinitrotouluene (TNT) and 1,3,5 trinitro-1,3,5-triazine (RDX), chemical agent dimethyl methylphosphonate (DMMP), a broad range of organic vapors, such as toluene, benzene, ethylene and acetone, and mixtures of these gas-phase organic compounds. We discuss examples of the current trends in microfabricated preconcentrator technology as well as several applications of microfabricated preconcentrators.

[1]  E. Zellers,et al.  Multiple-stage microfabricated preconcentrator-focuser for micro gas chromatography system , 2005, Journal of Microelectromechanical Systems.

[2]  Edward T. Zellers,et al.  Microfabricated preconcentrator-focuser for a microscale gas chromatograph , 2003 .

[3]  K. Najafi,et al.  A wireless integrated microsystem for environmental monitoring , 2004, 2004 IEEE International Solid-State Circuits Conference (IEEE Cat. No.04CH37519).

[4]  K. Ward,et al.  Immobilization of cytochrome c oxidase into electrode-supported lipid bilayer membranes for in vitro cytochrome c sensing , 2006, IEEE Sensors Journal.

[5]  Chia-Jung Lu,et al.  Portable gas chromatograph with tunable retention and sensor array detection for determination of complex vapor mixtures. , 2003, Analytical chemistry.

[6]  R. A. McGill,et al.  Microfabricated vapor preconcentrator for portable ion mobility spectroscopy , 2007 .

[7]  J. M. Bauer,et al.  Recent advancements in the gas-phase MicroChemLab , 2006, IEEE Sensors Journal.

[8]  G. Eiceman,et al.  Ion Mobility Spectrometry: Arriving on Site and Moving beyond a Low Profile , 1999, Applied spectroscopy.

[9]  Edward T. Zellers,et al.  Vapor recognition with an integrated array of polymer-coated flexural plate wave sensors , 2000 .

[10]  E. Zellers,et al.  A dual-adsorbent preconcentrator for a portable indoor-VOC microsensor system. , 2001, Analytical chemistry.

[11]  Ronald P. Manginell,et al.  Microfabricated silicon gas chromatographic microchannels: fabrication and performance , 1998, Photonics West - Micro and Nano Fabricated Electromechanical and Optical Components.

[12]  W. K. Schubert,et al.  Gas phase chemical detection with an integrated chemical analysis system , 1999, Proceedings of the 1999 Joint Meeting of the European Frequency and Time Forum and the IEEE International Frequency Control Symposium (Cat. No.99CH36313).

[13]  Somenath Mitra,et al.  Continuous gas chromatographic monitoring of low concentration sample streams using an on-line microtrap , 1993 .

[14]  E. Zellers,et al.  Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: Selection and characterization of the preconcentrator adsorbent , 1998 .

[15]  S. Mitra,et al.  Microtrap modulated flame ionization detector for on-line monitoring of methane. , 2005, Journal of chromatography. A.

[16]  George R. Dulleck,et al.  Hand-Held Miniature Chemical Analysis System (μChemlab) for Detection of Trace Concentrations of Gas Phase Analytes , 2000 .

[17]  R. A. McGill,et al.  Micropreconcentrator for Enhanced Trace Detection of Explosives and Chemical Agents , 2006, IEEE Sensors Journal.

[18]  Patrick R. Lewis,et al.  Microfabricated planar preconcentrator , 2000 .

[19]  José Higino Correia,et al.  Single-chip CMOS optical microspectrometer , 2000 .

[20]  K. Najafi,et al.  An Integrated Micro-Analytical System for Complex Vapor Mixtures , 2007, TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference.

[21]  D. L. Baldwin,et al.  Progressive thermal desorption of vapor mixtures from a preconcentrator with a porous metal foam internal architecture and variable thermal ramp rates. , 2005, Analytical chemistry.

[22]  A. Noy,et al.  Ultrafast gas chromatography on single-wall carbon nanotube stationary phases in microfabricated channels. , 2006, Analytical chemistry.

[23]  G. Spangler Fundamental considerations for the application of miniature Ion mobility spectrometry to field analytical applications , 2000 .

[24]  S. Mitra,et al.  A microfabricated microconcentrator for sensors and gas chromatography. , 2003, Journal of chromatography. A.

[25]  Chi-Yen Shen,et al.  Gas-detecting properties of surface acoustic wave ammonia sensors , 2004 .

[26]  C. Huang,et al.  A sensitive and selective assay of nucleic acids by measuring enhanced total internal reflected resonance light scattering signals deriving from the evanescent field at the water/tetrachloromethane interfaceElectronic Supplementary Information (ESI) available: Figs. S1 and S2. See http://www.rsc.org , 2002 .

[27]  R. A. McGill,et al.  Towards Enhanced Detection of Chemical Agents: Design and Development of a Microfabricated Preconcentrator , 2007, TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference.

[28]  K. Wise,et al.  First-generation hybrid MEMS gas chromatograph. , 2005, Lab on a chip.

[29]  K. Wise,et al.  High-performance temperature-programmed microfabricated gas chromatography columns , 2005, Journal of Microelectromechanical Systems.