Development of a procedure for substantiating replacement terms for the condenser tubes of steam turbine installations
暂无分享,去创建一个
Results obtained from elaboration of a procedure for estimating replacement terms for the condenser tube systems of steam turbine installations are presented. Censored data processing methods are used in performing statistical assessment of replacement terms. The service life of condenser tubes blanked off in the course of turbine operation is assumed to be known (complete operation time), and that for tubes blanked off during the turbine repair process is assumed to be undetermined (censored operation time). The criterion for estimating the replacement term for a condenser tube system is defined as the ratio between the number of tubes blanked off during a repair and in the course of turbine operation. The procedure is validated by the results from a study on analyzing the damageability of tubes made of different materials for the condensers of 11 turbines with capacities ranging from 25 to 500 MW.
[1] V. G. Kritskii,et al. Corrosion of copper-alloy tubes in cooling systems of nuclear power stations , 1997 .
[2] B. E. Murmanskii,et al. An analysis of indicators characterizing the reliability of auxiliary equipment of power units , 2011 .
[3] V. I. Nikitin. Corrosive damage to the condensers of steam turbines and determining the residual life of their tube system , 2001 .