Distributed Multiple Tuned Mass Dampers for Wind Response Control of Chimney with Flexible Foundation

Abstract Multi-mode wind response control of chimneys on flexible foundation is studied. The multi-mode control is achieved using distributed multiple tuned mass dampers (d-MTMDs). A reinforced concrete (RC) chimney is considered as an assemblage of beam elements, each assumed to have constant diameter over the element length, and soil-structure interaction (SSI) is duly accounted for. The soil is idealized in single strata beneath the foundation, which consist of annular raft foundation having the internal and external diameter 15 m and 40 m, respectively and having depth of 2.5 m. The raft and the surrounding soil are modeled considering frequency independent constants for the springs and dashpots. The time domain wind analysis based on Newmark’s method of average acceleration is employed for the non-classically damped system. The performance of the d-MTMDs is compared with the case of single tuned mass damper (STMD), d-MTMDs controlling the fundamental modal responses (d-MTMDs-1), and arbitrarily installed distributed MTMDs (ad-MTMDs). The displacement and acceleration response at the top of the chimney under wind forces are computed to study the effectiveness in the STMD, d-MTMDs-1, ad-MTMDs, and d-MTMDs cases. It is concluded that the d-MTMDs are more effective than the STMD, d-MTMDs-1, and ad-MTMDs, while considering equal total mass of the TMD(s). Furthermore, the soil type greatly affects the design parameters of the STMD/ d-MTMDs-1/ ad-MTMDs/ d-MTMDs, and wind response of the chimney with flexible foundation.

[1]  B. J. Watt,et al.  Earthquake Survivability of Concrete Platforms , 1980 .

[2]  Wei-Ling Chiang,et al.  Wind-induced vibration of high-rise building with tuned mass damper including soil–structure interaction , 2008 .

[3]  Kenny C. S Kwok,et al.  Closure of "Wind-Induced Lock-In Excitation of Tall Structures" , 1982 .

[4]  Giovanni Solari,et al.  An evaluation technique for vibration modes of structures interacting with soil , 1981 .

[5]  Vasant Matsagar,et al.  Distributed Multiple Tuned Mass Dampers for Wind Vibration Response Control of High-Rise Building , 2014 .

[6]  R. S. Jangid,et al.  Optimum parameters of multiple tuned mass dampers for base-excited damped systems , 1997 .

[7]  T. K. Datta,et al.  An analytical study of the across-wind response of cylinders due to vortex shedding , 1987 .

[8]  Vasant Matsagar,et al.  Optimum Tuned Mass Damper for Wind and Earthquake Response Control of High-Rise Building , 2015 .

[9]  Spg Madabhushi,et al.  An experimental investigation of soil-structure interaction in a sway frame structure with tuned mass dampers , 2014 .

[10]  Chunxiang Li,et al.  Optimum multiple tuned mass dampers for structures under the ground acceleration based on DDMF and ADMF , 2002 .

[11]  R. S. Jangid Optimum Multiple Tuned Mass Dampers for base‐excited undamped system , 1999 .

[12]  Rn Jabary,et al.  Tuned mass damper effects on the response of multi-storied structures observed in geotechnical centrifuge tests , 2015 .

[13]  F. Casciati,et al.  Performance of Multi-TMD in the Towers of Suspension Bridges , 2009 .

[14]  Vasant Matsagar,et al.  Wind Response Control of 76-Storey Benchmark Building with Distributed Multiple Tuned Mass Dampers , 2013 .

[15]  Fabio Casciati,et al.  Tuned Mass Dampers in the Towers of Suspension Bridges , 2006 .

[16]  B. J. Vickery,et al.  Lift or Across-Wind Response to Tapered Stacks , 1972 .

[17]  Bernd Beirow,et al.  Theoretical and experimental free vibrations of tall industrial chimney with flexibility of soil , 2005 .

[18]  Vasant Matsagar,et al.  Effectiveness of distributed tuned mass dampers for multi-mode control of chimney under earthquakes , 2016 .

[19]  Bingkang Han,et al.  Effect of dominant ground frequency and soil on multiple tuned mass dampers , 2011 .

[20]  Sriram Narasimhan,et al.  Extended Kalman filter for modal identification of structures equipped with a pendulum tuned mass damper , 2014 .

[21]  Marco Zucca,et al.  A chimney’s seismic assessment by a tuned mass damper , 2014 .

[22]  A. Kareem Mitigation of wind induced motion of tall buildings , 1983 .

[23]  N. Lakshmanan,et al.  Across-wind aerodynamic parameters of tall chimneys with circular , 2001 .

[24]  B. Basu,et al.  Effect of soil interaction on the performance of tuned mass dampers for seismic applications , 2004 .

[25]  R. S. Jangid,et al.  Optimization of multiple tuned mass dampers for vibration control of system under external excitation , 2013 .