Dosimetric impact of intra-fraction motion during high dose rate stereotactic vertebral radiotherapy using flattened and flattening filter free beams

PURPOSE Flattening filter-free (FFF) beams with higher dose rates and faster delivery are now clinically available. The purpose of this planning study was to compare optimized non-FFF and FFF RapidArc plans for stereotactic body radiotherapy (SBRT) and to validate the accuracy of fast arc delivery. METHODS AND MATERIAL Ten patients with peripheral lung tumors and 10 with vertebral metastases were planned using RapidArc with a flattened 6-MV photon beam and a 10-MV FFF beam for fraction doses of 7.5-18 Gy. Dosimetry of the target and organs at risk (OAR), number of monitor units (MU), and beam delivery times were assessed. GafChromic EBT2 film measurements of FFF plans were performed to compare calculated and delivered dose distributions. RESULTS No major dosimetric differences were seen between the two delivery techniques. For lung SBRT plans, conformity indices and OAR doses were similar, although the average MU required were higher with FFF plans. For vertebral SBRT, FFF plans provided comparable PTV coverage, with no significant differences in OAR doses. Average beam delivery times were reduced by a factor of up to 2.5, with all FFF fractions deliverable within 4 min. Measured FFF plans showed high agreement with calculated plans, with more than 99% of the area within the region of interest fulfilling the acceptance criterion. CONCLUSION The higher dose rate of FFF RapidArc reduces delivery times significantly, without compromising plan quality or accuracy of dose delivery.

[1]  Nzhde Agazaryan,et al.  Image-guided radiosurgery for spinal tumors: methods, accuracy and patient intrafraction motion , 2008, Physics in medicine and biology.

[2]  Joachim Widder,et al.  Recommendations for implementing stereotactic radiotherapy in peripheral stage IA non-small cell lung cancer: report from the Quality Assurance Working Party of the randomised phase III ROSEL study , 2009, Radiation oncology.

[3]  Radhe Mohan,et al.  Dosimetric properties of photon beams from a flattening filter free clinical accelerator , 2005, Physics in medicine and biology.

[4]  Fang-Fang Yin,et al.  6D image guidance for spinal non-invasive stereotactic body radiation therapy: Comparison between ExacTrac X-ray 6D with kilo-voltage cone-beam CT. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  K. Sheng,et al.  Evaluation of thoracic spinal cord motion using dynamic MRI. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  Hosang Jin,et al.  A study on target positioning error and its impact on dose variation in image-guided stereotactic body radiotherapy for the spine. , 2009, International journal of radiation oncology, biology, physics.

[7]  Radhe Mohan,et al.  Stereotactic radiotherapy for lung cancer using a flattening filter free Clinac , 2009, Journal of applied clinical medical physics.

[8]  D. Larson,et al.  Stereotactic body radiosurgery for spinal metastases: a critical review. , 2008, International journal of radiation oncology, biology, physics.

[9]  Suresh Senan,et al.  Dosimetric impact of interplay effect on RapidArc lung stereotactic treatment delivery. , 2011, International journal of radiation oncology, biology, physics.

[10]  Jingeng Zhu,et al.  Image‐guided and intensity‐modulated radiosurgery for patients with spinal metastasis , 2003, Cancer.

[11]  E. Smit,et al.  Outcomes of risk-adapted fractionated stereotactic radiotherapy for stage I non-small-cell lung cancer. , 2008, International journal of radiation oncology, biology, physics.

[12]  Anton Mans,et al.  Volumetric-modulated arc therapy for stereotactic body radiotherapy of lung tumors: a comparison with intensity-modulated radiotherapy techniques. , 2011, International journal of radiation oncology, biology, physics.

[13]  D. Jaffray,et al.  Impact of Immobilization on Intra-fraction Motion for Spine Stereotactic Body Radiotherapy (SBRT) using Cone-beam CT (CBCT) , 2010 .

[14]  Fang-Fang Yin,et al.  Impact of collimator leaf width and treatment technique on stereotactic radiosurgery and radiotherapy plans for intra- and extracranial lesions , 2009, Radiation oncology.

[15]  I. Lohse,et al.  Effect of high dose per pulse flattening filter-free beams on cancer cell survival. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[16]  Meic H. Schmidt,et al.  Surgical management of spinal metastases. , 2004, The oncologist.

[17]  William C Welch,et al.  Radiosurgery for Spinal Metastases: Clinical Experience in 500 Cases From a Single Institution , 2007, Spine.

[18]  Suresh Senan,et al.  Volumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study. , 2009, International journal of radiation oncology, biology, physics.

[19]  S. Senan,et al.  Volumetric modulated arc therapy versus conventional intensity modulated radiation therapy for stereotactic spine radiotherapy: a planning study and early clinical data. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[20]  Lijun Ma,et al.  Nonrandom intrafraction target motions and general strategy for correction of spine stereotactic body radiotherapy. , 2009, International journal of radiation oncology, biology, physics.

[21]  Peter C Levendag,et al.  Time dependence of intrafraction patient motion assessed by repeat stereoscopic imaging. , 2008, International journal of radiation oncology, biology, physics.

[22]  Radhe Mohan,et al.  Dosimetric effect of translational and rotational errors for patients undergoing image-guided stereotactic body radiotherapy for spinal metastases. , 2008, International journal of radiation oncology, biology, physics.

[23]  Niko Papanikolaou,et al.  Treatment planning and delivery of IMRT using 6 and 18MV photon beams without flattening filter. , 2009, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[24]  H. V. van Houwelingen,et al.  Patients with a favourable prognosis are equally palliated with single and multiple fraction radiotherapy: results on survival in the Dutch Bone Metastasis Study. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[25]  Suresh Senan,et al.  Stereotactic radiotherapy for peripheral lung tumors: a comparison of volumetric modulated arc therapy with 3 other delivery techniques. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[26]  Steven D Chang,et al.  Image-guided robotic radiosurgery for spinal metastases. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[27]  B. S. Sørensen,et al.  Dependence of cell survival on instantaneous dose rate of a linear accelerator. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[28]  Ik Jae Lee,et al.  Early clinical experience and outcome of helical tomotherapy for multiple metastatic lesions. , 2007, International journal of radiation oncology, biology, physics.

[29]  B. Taylor,et al.  Image-guided stereotactic body radiotherapy for lung tumors using BodyLoc with tomotherapy: clinical implementation and set-up accuracy. , 2010, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[30]  Tommy Knöös,et al.  Dosimetric characteristics of 6 and 10MV unflattened photon beams. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[31]  K. Bratengeier,et al.  Precision required for dose-escalated treatment of spinal metastases and implications for image-guided radiation therapy (IGRT). , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[32]  Quynh-Thu Le,et al.  Patterns of patient movement during frameless image-guided radiosurgery. , 2003, International journal of radiation oncology, biology, physics.

[33]  J. Kuijer,et al.  Imaging for stereotactic spine radiotherapy: clinical considerations. , 2011, International journal of radiation oncology, biology, physics.