Airtightness and ventilation in a mild climate country rehabilitated social housing buildings – What users want and what they get

Abstract Dwellings should be designed for users' wellbeing but frequently their actions seem to contradict the logic adopted in the design. The impact of users' actions and habits on buildings energy efficiency is well established and documented. However, there is a lack of available information concerning the relationship between user behaviour, building airtightness and ventilation. This paper explores the results of a large experimental campaign, which included: airtightness measurements by fan pressurization of flats; continuous CO 2 measurements, and a questionnaire regarding tenants' habits. Forty nine apartments from two different social housing neighbourhoods, one of them recently rehabilitated, were used as case study. Non-rehabilitated flats presented an average ACH 50 of 8.9 h −1 while the rehabilitated flats presented an average of 6.8 h −1 . The impact of user behaviour in airtightness levels was investigated and, in the rehabilitated case study, the average ACH 50 was 4.3 h −1 in modified flats and 7.7 h −1 in non-modified. This can have important consequences on the indoor environment as the average ACH found in a modified flat, ranged from 0.35 h −1 , in December to 1.01 h −1 in August, showing the importance of window opening in the actual ventilation rates. The standard methods for estimating average ventilation rates were applied to the sample and results compared with measurements, indicating a need to adapt currently used methodologies to adequately include user effect. The complexity of human behaviour is a challenge for designers and therefore increasing the knowledge of user actions and habits is decisive for building better homes.

[1]  Mats Sandberg,et al.  A quantitative estimate of the accuracy of tracer gas methods for the determination of the ventilation flow rate in buildings , 1985 .

[2]  Z. Buliński,et al.  Experimentally validated CFD analysis on sampling region determination of average indoor carbon dioxide concentration in occupied space , 2014 .

[3]  Olivia Guerra Santin,et al.  Behavioural Patterns and User Profiles related to energy consumption for heating , 2011 .

[4]  K. K. Andersen,et al.  Survey of occupant behaviour and control of indoor environment in Danish dwellings , 2007 .

[5]  Max H. Sherman Infiltration in ASHRAE's Residential Ventilation Standards , 2008 .

[6]  Max H. Sherman,et al.  Analysis of air leakage measurements of US houses , 2013 .

[7]  A. Emery,et al.  A long term study of residential home heating consumption and the effect of occupant behavior on homes in the Pacific Northwest constructed according to improved thermal standards , 2006 .

[8]  Wei Pan,et al.  Relationships between air-tightness and its influencing factors of post-2006 new-build dwellings in the UK , 2010 .

[9]  J. Kurnitski,et al.  The effects of ventilation systems and building fabric on the stability of indoor temperature and humidity in Finnish detached houses , 2009 .

[10]  Marco Dell'Isola,et al.  Experimental analysis of air tightness in Mediterranean buildings using the fan pressurization method , 2012 .

[11]  Man Pun Wan,et al.  Ventilation performance measurement using constant concentration dosing strategy , 2004 .

[12]  M. Liddament,et al.  A guide to energy efficient ventilation , 1996 .

[13]  J. Fitzgerald,et al.  Measured Change in Multifamily Unit Air Leakage and Airflow Due to Air Sealing and Ventilation Treatments , 2007 .

[14]  Marian B. Nantka Indoor Conditions in Silesian Buildings with Natural Ventilation , 2006 .

[15]  Juan J. Sendra,et al.  Protocols for measuring the airtightness of multi-dwelling units in Southern Europe , 2011 .

[16]  Targo Kalamees,et al.  Air tightness and air leakages of new lightweight single-family detached houses in Estonia , 2007 .

[17]  Henk Visscher,et al.  The effect of occupancy and building characteristics on energy use for space and water heating in Dutch residential stock , 2009 .

[18]  Derek Sinnott,et al.  Air-tightness field data for dwellings in Ireland , 2012 .

[19]  Dominique Marchio,et al.  CO2 tracer gas concentration decay method for measuring air change rate , 2015 .

[20]  Tao Lu,et al.  A novel methodology for estimating space air change rates and occupant CO2 generation rates from measurements in mechanically-ventilated buildings , 2010 .

[21]  V. P. de Freitas,et al.  Air permeability measurements of dwellings and building components in Portugal , 2011 .

[22]  Pablo Branchi,et al.  A study of air leakage in residential buildings , 2013, 2013 International Conference on New Concepts in Smart Cities: Fostering Public and Private Alliances (SmartMILE).

[23]  Alberto Meiss,et al.  The energy impact of infiltration: a study on buildings located in north central Spain , 2015 .