Electro-acoustic detection, identification and location of partial discharge sources in oil-paper insulation systems

The detection of Partial Discharges (PD) is a reliable technique to analyze the status of electrical insulation in power transformers. Phase resolved partial discharge patterns are being complemented with high frequency pulse waveform analysis, in order to identify discharge sources. In addition to this, acoustic techniques are being implemented trying to locate PD sites in large power transformers. In this work, an inductive loop sensor will be used to identify two different PD sources by means of the energy distribution of the detected waveforms. Additionally, these PD sources will be located by means of acoustic measurements with an electrical reference, through the analysis of the acoustic activity detected for each sensor individually.

[1]  E. Howells,et al.  Parameters Affecting the Velocity of Sound in Transformer Oil , 1984, IEEE Power Engineering Review.

[2]  S. Tenbohlen,et al.  Sensitivity of UHF PD measurements in power transformers , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[3]  L. Niemeyer A generalized approach to partial discharge modeling , 1995 .

[4]  P. M. Eleftherion Partial discharge. XXI. Acoustic emission based PD source location in transformers , 1995 .

[5]  Guillermo Robles,et al.  Partial discharge pulse shape recognition using an inductive loop sensor , 2010 .

[6]  Javier Sanz-Feito,et al.  Inductive Sensor for Measuring High Frequency Partial Discharges Within Electrical Insulation , 2009, IEEE Transactions on Instrumentation and Measurement.

[7]  Ronald Harrold The Relationship Between Ultrasonic and Electrical Measurements of Under-Oil Corona Sources , 1976, IEEE Transactions on Electrical Insulation.

[8]  J. Ramírez-Niño,et al.  Acoustic measuring of partial discharge in power transformers , 2009 .

[9]  H Lee Willis,et al.  Aging Power Delivery Infrastructures , 2000 .

[10]  S. Tenbohlen,et al.  Detection and location of partial discharges in power transformers using acoustic and electromagnetic signals , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[11]  Ieee Standards Board IEEE guide for the interpretation of gases generated in oil-immersed transformers , 1992 .

[12]  R. Bartnikas,et al.  Trends in partial discharge pattern classification: a survey , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[13]  Jose A. Garcia-Souto,et al.  Detection and Location of Acoustic and Electric Signals from Partial Discharges with an Adaptative Wavelet-Filter Denoising , 2011 .

[14]  Philip J. Moore,et al.  A nonintrusive partial discharge measurement system based on RF technology , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[15]  G. H. Vaillancourt,et al.  Propagation behaviour of acoustic partial discharge signals in oil-filled transformers , 1996, ICDL'96. 12th International Conference on Conduction and Breakdown in Dielectric Liquids.

[16]  G. C. Montanari,et al.  Comparison of ultrasonic, electrical and UHF characteristics of partial discharge emission in oil/paper insulation systems , 2011, 2011 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.

[17]  Gian Carlo Montanari,et al.  A new approach to the diagnosis of solid insulation systems based on PD signal inference , 2003 .

[18]  H. Okubo,et al.  A novel technique for partial discharge and breakdown investigation based on current pulse waveform analysis , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.