Spectroscopic Performance of TERA: Fast Multichannel Analog Pulse Processor ASIC for X-ray Detection Applications

This work reports the spectroscopic performance of the latest release of TERA (Throughput Enhanced Readout ASIC), a multichannel analog pulse processor (APP) ASIC suitable for detectors in ultra-high rate X-ray detection applications (>1Mcps/channel). The chip has been developed to process signals coming from Silicon Drift Detectors (SDDs) coupled with resettype Charge Sensitive Amplifiers (CSA). The demonstrator chip is composed of 4 parallel readout channels, each channel is composed by 7th-order semi-Gaussian shaping-amplifier with adjustable shaping times and dynamic range, followed by a peak stretcher and an analog memory. Each pair of channels can be optionally digitized by 12-bit on-chip ADC, providing the maximum sampling frequency up to 2.5MHz. TERA architecture enables to achieve simultaneously high throughput and satisfactory energy resolution. In 55Fe spectroscopy measurements using SDD collimated to 4mm diameter, at the shortest pulse width of 200ns, FWHM Mn-Ka line of 171.5eV and 205.1eV were obtained at input rate 10kcps and 1.61Mcps, respectively. At 1.61Mcps input rate, 1.09Mcps throughput was achieved. High-rate performances are, to our knowledge, the best ones for a Spectroscopy analog ASIC and are close to the ones achievable with standard DPPs. Therefore, TERA can represent an attractive detector pulse processing solution for high-density multichannel detection systems.

[1]  M. Carminati,et al.  Assessment of analog pulse processor performance for ultra high-rate x-ray spectroscopy , 2019, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.

[2]  M. Carminati,et al.  Characterization of the First Prototype of TERA: A Readout ASIC for Ultra High Rate X-ray Detection Applications , 2018, 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC).

[3]  M. Carminati,et al.  ARDESIA Detection Module: A Four-Channel Array of SDDs for Mcps X-Ray Spectroscopy in Synchrotron Radiation Applications , 2018, IEEE Transactions on Nuclear Science.

[4]  C. Fiorini,et al.  SFERA: An Integrated Circuit for the Readout of X and $\gamma $ -Ray Detectors , 2016, IEEE Transactions on Nuclear Science.

[5]  M. Occhipinti,et al.  Silicon Drift Detectors and CUBE Preamplifiers for High-Resolution X-ray Spectroscopy , 2015, IEEE Transactions on Nuclear Science.

[6]  L. Bombelli,et al.  “CUBE”, A low-noise CMOS preamplifier as alternative to JFET front-end for high-count rate spectroscopy , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[7]  Jack Fried,et al.  ASIC for SDD-Based X-Ray Spectrometers , 2010, IEEE Transactions on Nuclear Science.