Correlation of optic nerve and optic nerve sheath diameter with intracranial pressure in pigs

Objective Several studies have shown an association between intracranial pressure and the diameter of the optic nerve sheath measured by transbulbar ultrasonography. To understand the pathophysiology of this phenomenon, we aimed to measure the changes of the optic nerve, optic nerve sheath and perineural space separately with increasing intracranial pressure in a porcine model. Methods An external ventricular drain was placed into the third ventricle through a right paramedian burrhole in eight anesthesized pigs. The diameters of the optic nerve and the optic nerve sheath were measured while the intracranial pressure (ICP) was increased in steps of 10mmHg from baseline up to 60 mmHg. Results The median diameters of the optic nerve (ON) increased from 0.36 cm (baseline– 95% confidence interval (CI) 0.33 cm to 0.45 cm) to 0.68 cm (95% CI 0.57 cm to 0.82 cm) at ICP of 60 mmHg (p<0.0001) and optic nerve sheath (ONS) from 0.88 cm (95% CI 0.79 cm to 0.98 cm) to 1.24 cm (95% CI 1.02 cm to 1.38 cm) (p< 0.002) while the median diameter of the perineural space (PNS) (baseline diameter 95% CI 0.40 cm to 0.59 cm to diameters at ICP 60 95% CI 0.38 cm to 0.62 cm) did not change significantly (p = 0.399). Multiple comparisons allowed differentiation between baseline and values ≥40 mmHg for ON (p = 0.017) and between baseline and values ≥ 50mmHg for ONS (p = 0.006). A linear correlation between ON (R2 = 0.513, p<0.0001) and ONS (R2 = 0.364, p<0.0001) with ICP was found. The median coefficient of variation for intra- and inter-investigator variability was 8% respectively 2.3%. Conclusion Unexpectedly, the increase in ONS diameter with increasing ICP is exclusively related to the increase of the diameter of the ON. Further studies should explore the reasons for this behaviour.

[1]  Arndt-Hendrik Schievelkamp,et al.  Sonographic assessment of the optic nerve and the central retinal artery in idiopathic intracranial hypertension , 2020, Journal of Clinical Neuroscience.

[2]  M. Taljaard,et al.  Diagnosis of elevated intracranial pressure in critically ill adults: systematic review and meta-analysis , 2019, BMJ.

[3]  A. Candeliere Merlicco,et al.  Transorbital ultrasonography for measuring optic nerve atrophy in multiple sclerosis , 2018, Acta neurologica Scandinavica.

[4]  U. Baumann,et al.  Noninvasive Assessment of Intra-Abdominal Pressure Using Ultrasound-Guided Tonometry: A Proof-of-Concept Study , 2017, Shock.

[5]  S. Jakob,et al.  Compression sonography for non-invasive measurement of lower leg compartment pressure in an animal model. , 2017, Injury.

[6]  J. Takala,et al.  Gastrointestinal Impedance Spectroscopy to Detect Hypoperfusion During Hemorrhage , 2017, Shock.

[7]  Xinghuai Sun,et al.  High‐resolution transbulbar ultrasonography helping differentiate intracranial hypertension in bilateral optic disc oedema patients , 2017, Acta ophthalmologica.

[8]  Mark H. Wilson,et al.  Monro-Kellie 2.0: The dynamic vascular and venous pathophysiological components of intracranial pressure , 2016, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[9]  Francesco Brigo,et al.  Intra- and interobserver reliability of transorbital sonographic assessment of the optic nerve sheath diameter and optic nerve diameter in healthy adults , 2016, Journal of Ultrasound.

[10]  E. Arsava,et al.  Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter in Brain Death , 2015, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[11]  A. Raabe,et al.  Management of spontaneous intracranial hypotension – Transorbital ultrasound as discriminator , 2015, Journal of Neurology, Neurosurgery & Psychiatry.

[12]  P. Smielewski,et al.  Doppler Non-invasive Monitoring of ICP in an Animal Model of Acute Intracranial Hypertension , 2015, Neurocritical Care.

[13]  Derek M Nusbaum,et al.  Elevated intracranial pressure causes optic nerve and retinal ganglion cell degeneration in mice. , 2015, Experimental eye research.

[14]  Diederik Gommers,et al.  Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure. , 2015, Journal of neurosurgery.

[15]  Dao-Yi Yu,et al.  Comparative quantitative study of astrocytes and capillary distribution in optic nerve laminar regions. , 2014, Experimental eye research.

[16]  Jonathan B. Clark,et al.  Intracranial pressure and optic nerve sheath diameter as cephalic venous pressure increases in swine. , 2013, Aviation, space, and environmental medicine.

[17]  V. Noble,et al.  Individual patient data systematic review and meta-analysis of optic nerve sheath diameter ultrasonography for detecting raised intracranial pressure: protocol of the ONSD research group , 2013, Systematic Reviews.

[18]  H. Qayyum,et al.  Can ocular ultrasound predict intracranial hypertension? A pilot diagnostic accuracy evaluation in a UK emergency department , 2013, European journal of emergency medicine : official journal of the European Society for Emergency Medicine.

[19]  P. De Bonis,et al.  Blood flow velocities during experimental intracranial hypertension in pigs , 2012, Neurological research.

[20]  M. Köhrmann,et al.  Neurosonografie in der neurologischen Notfall- und Intensivmedizin: Monitoring des erhöhten intrakraniellen Druckes, Hirntoddiagnostik und Untersuchung der zerebralen Autoregulation – Teil 2 , 2012, Ultraschall in der Medizin.

[21]  O. Simanski,et al.  A surgical technique for a terminal intracranial hypertension model in pigs , 2012, Laboratory animals.

[22]  M. Köhrmann,et al.  Neurosonografie in der neurologischen Notfall- und Intensivmedizin: Grundlagen, vaskuläre Schlaganfalldiagnostik und Monitoring – Teil 1 , 2012, Ultraschall in der Medizin.

[23]  M. Kaps,et al.  Intra‐ and Interobsever Reliability of Sonographic Assessment of the Optic Nerve Sheath Diameter in Healthy Adults , 2012, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[24]  A. Sargsyan,et al.  Sonography for Determining the Optic Nerve Sheath Diameter With Increasing Intracranial Pressure in a Porcine Model , 2011, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[25]  T. Geeraerts,et al.  Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis , 2011, Intensive Care Medicine.

[26]  D. Menon,et al.  Use of T2-weighted magnetic resonance imaging of the optic nerve sheath to detect raised intracranial pressure , 2008, Critical care.

[27]  D. Benhamou,et al.  Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients , 2008, Intensive Care Medicine.

[28]  Nils R Frühauf,et al.  Method of intracranial pressure monitoring and cerebrospinal fluid sampling in swine , 2007, Laboratory animals.

[29]  B. Milne,et al.  Central dexmedetomidine attenuates cardiac dysfunction in a rodent model of intracranial hypertension , 2004, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[30]  H. Hansen,et al.  Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. , 1997, Journal of neurosurgery.

[31]  Jonathan B. Clark,et al.  Optic nerve sheath diameter measurement techniques: examination using a novel ex-vivo porcine model. , 2014, Aviation, space, and environmental medicine.

[32]  U. Schminke,et al.  The potential of neurosonography in neurological emergency and intensive care medicine: monitoring of increased intracranial pressure, brain death diagnostics, and cerebral autoregulation– part 2. , 2012, Ultraschall in der Medizin.

[33]  U. Schminke,et al.  [The potential of neurosonography in neurological emergency and intensive care medicine: basic principles, vascular stroke diagnostics, and monitoring of stroke-specific therapy - Part 1]. , 2012, Ultraschall in der Medizin.