A biophysical model of atrial fibrillation ablation: what can a surgeon learn from a computer model?

AIMS Surgical ablation procedures for treating atrial fibrillation have been shown to be highly successful. However, the ideal ablation pattern still remains to be determined. This article reports on a systematic study of the effectiveness of the performance of different ablation line patterns. METHODS AND RESULTS This study of ablation line patterns was performed in a biophysical model of human atria by combining basic lines: (i) in the right atrium: isthmus line, line between vena cavae and appendage line and (ii) in the left atrium: several versions of pulmonary vein isolation, connection of pulmonary veins, isthmus line, and appendage line. Success rates and the presence of residual atrial flutter were documented. Basic patterns yielded conversion rates of only 10-25 and 10-55% in the right and the left atria, respectively. The best result for pulmonary vein isolation was obtained when a single closed line encompassed all veins (55%). Combination of lines in the right/left atrium only led to a success rate of 65/80%. Higher rates, up to 90-100%, could be obtained if right and left lines were combined. The inclusion of a left isthmus line was found to be essential for avoiding uncommon left atrial flutter. CONCLUSION Some patterns studied achieved a high conversion rate, although using a smaller number of lines than those of the Maze III procedure. The biophysical atrial model is shown to be effective in the search for promising alternative ablation strategies.

[1]  J L Cox,et al.  Modification of the maze procedure for atrial flutter and atrial fibrillation. II. Surgical technique of the maze III procedure. , 1995, The Journal of thoracic and cardiovascular surgery.

[2]  B. Lemke,et al.  Surgical treatment of atrial fibrillation; a systematic review. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[3]  M. Borgers,et al.  Structural remodelling during chronic atrial fibrillation: act of programmed cell survival. , 2001, Cardiovascular research.

[4]  C. Henriquez,et al.  A computer model of normal conduction in the human atria. , 2000, Circulation research.

[5]  N. Virag,et al.  Evaluation of Ablation Patterns Using a Biophysical Model of Atrial Fibrillation , 2005, Annals of Biomedical Engineering.

[6]  A. Holden,et al.  Heterogeneous three-dimensional anatomical and electrophysiological model of human atria , 2006, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[7]  J Clémenty,et al.  Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. , 1998, The New England journal of medicine.

[8]  Fred Morady,et al.  Catheter Ablation of Supraventricular Arrhythmias: , 2004, Pacing and clinical electrophysiology : PACE.

[9]  Nathalie Virag,et al.  A biophysical model of atrial fibrillation to define the appropriate ablation pattern in modified maze. , 2007, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[10]  E. Braunwald Shattuck lecture--cardiovascular medicine at the turn of the millennium: triumphs, concerns, and opportunities. , 1997, The New England journal of medicine.

[11]  L. V. von Segesser,et al.  Left atrial radiofrequency compartmentalization for chronic atrial fibrillation during heart surgery. , 2002, The Thoracic and cardiovascular surgeon.

[12]  S Nattel,et al.  Potential Ionic Mechanism for Repolarization Differences Between Canine Right and Left Atrium , 2001, Circulation research.

[13]  J. Cox Atrial transport function after the maze procedure for atrial fibrillation: a 10-year clinical experience. , 1998, American heart journal.

[14]  Nathalie Virag,et al.  Wavelength and vulnerability to atrial fibrillation: Insights from a computer model of human atria. , 2005, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[15]  M Borggrefe,et al.  Intraoperative Radiofrequency Ablation of Chronic Atrial Fibrillation: A Left Atrial Curative Approach by Elimination of Anatomic “Anchor” Reentrant Circuits , 1999, Journal of cardiovascular electrophysiology.

[16]  C. Luo,et al.  A model of the ventricular cardiac action potential. Depolarization, repolarization, and their interaction. , 1991, Circulation research.

[17]  Michel Haïssaguerre,et al.  Impact of Varying Ablation Patterns in a Simulation Model of Persistent Atrial Fibrillation , 2007, Pacing and clinical electrophysiology : PACE.

[18]  W. Rheinboldt,et al.  A COMPUTER MODEL OF ATRIAL FIBRILLATION. , 1964, American heart journal.

[19]  G. Feld,et al.  Right Atrial Compartmentalization Using Radiofrequency Catheter Ablation for Management of Patients with Refractory Atrial Fibrillation , 1999, Journal of cardiovascular electrophysiology.

[20]  J. Boineau,et al.  Modification of the maze procedure for atrial flutter and atrial fibrillation. I. Rationale and surgical results. , 1995, The Journal of thoracic and cardiovascular surgery.

[21]  N Trayanova,et al.  Reentry in a Morphologically Realistic Atrial Model , 2001, Journal of cardiovascular electrophysiology.

[22]  Y Rudy,et al.  Cellular responses to electrical stimulation: a study using a model of the ventricular cardiac action potential. , 1993, Advances in experimental medicine and biology.

[23]  Nathalie Virag,et al.  Use of a biophysical model of atrial fibrillation in the interpretation of the outcome of surgical ablation procedures. , 2007, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[24]  F. Morady,et al.  Catheter Ablation of Supraventricular Arrhythmias: , 2004 .

[25]  J. Cox,et al.  Impact of the maze procedure on the stroke rate in patients with atrial fibrillation. , 1999, The Journal of thoracic and cardiovascular surgery.

[26]  José Jalife,et al.  Mechanisms of Atrial Fibrillation Termination by Pure Sodium Channel Blockade in an Ionically-Realistic Mathematical Model , 2005, Circulation research.