OpenWSI: a low-cost, high-throughput whole slide imaging system via single-frame autofocusing and open-source hardware

Recent advancements in whole slide imaging (WSI) have moved pathology closer to digital practice. Existing systems require precise mechanical control and the cost is prohibitive for most individual pathologists. Here we report a low-cost and high-throughput WSI system termed OpenWSI. The reported system is built using off-the-shelf components including a programmable LED array, a photographic lens, and a low-cost computer numerical control (CNC) router. Different from conventional WSI platforms, our system performs real-time single-frame autofocusing using color-multiplexed illumination. For axial positioning control, we perform coarse adjustment using the CNC router and precise adjustment using the ultrasonic motor ring in the photographic lens. By using a 20X objective lens, we show that the OpenWSI system has a resolution of ~0.7 microns. It can acquire whole slide images of a 225-mm^2 region in ~2 mins, with throughput comparable to existing high-end platforms. The reported system offers a turnkey solution to transform the high-end WSI platforms into one that can be made broadly available and utilizable without loss of capacity.

[1]  I T Young,et al.  A comparison of different focus functions for use in autofocus algorithms. , 1985, Cytometry.

[2]  Kaikai Guo,et al.  Rapid focus map surveying for whole slide imaging with continues sample motion , 2017, Optics letters.

[3]  R. Horstmeyer,et al.  Wide-field, high-resolution Fourier ptychographic microscopy , 2013, Nature Photonics.

[4]  Changhuei Yang,et al.  Microscopy refocusing and dark-field imaging by using a simple LED array. , 2011, Optics letters.

[5]  Kaikai Guo,et al.  Microscopy illumination engineering using a low-cost liquid crystal display. , 2015, Biomedical optics express.

[6]  Michael C. Montalto,et al.  Autofocus methods of whole slide imaging systems and the introduction of a second-generation independent dual sensor scanning method , 2011, Journal of pathology informatics.

[7]  Kaikai Guo,et al.  Fourier Ptychography for Brightfield, Phase, Darkfield, Reflective, Multi-Slice, and Fluorescence Imaging , 2016, IEEE Journal of Selected Topics in Quantum Electronics.

[8]  Siavash Yazdanfar,et al.  Simple and robust image-based autofocusing for digital microscopy. , 2008, Optics express.

[9]  C. Ortiz de Solórzano,et al.  Evaluation of autofocus functions in molecular cytogenetic analysis , 1997, Journal of microscopy.

[10]  Liron Pantanowitz,et al.  Current State of the Regulatory Trajectory for Whole Slide Imaging Devices in the USA , 2017, Journal of pathology informatics.

[11]  Richard R McKay,et al.  The accuracy of dynamic predictive autofocusing for whole slide imaging , 2011, Journal of pathology informatics.

[12]  Andrew Evans,et al.  Digital imaging in pathology: whole-slide imaging and beyond. , 2013, Annual review of pathology.

[13]  Shaowei Jiang,et al.  Rapid and robust whole slide imaging based on LED-array illumination and color-multiplexed single-shot autofocusing. , 2019, Quantitative imaging in medicine and surgery.