Tomotherapeutic portal imaging for radiation treatment verification.

In their tomotherapy concept Mackie and co-workers proposed not only a new technique for IMRT but also an appropriate and satisfactory method of treatment verification. This method allows both monitoring of the portal dose distribution and imaging of the patient anatomy during treatment by means of online CT. This would enable the detection of inaccuracies in dose delivery and patient set-up errors. In this paper results are presented showing that a single electronic portal imaging device (EPID) could deliver all data necessary to establish such a complete verification system for tomotherapy and even other IMRT techniques. Consequently it has to be shown that it is able to record both the low-intensity photon fluences encountered in tomographic imaging and the intense photon transmission of each treatment field. The detector under investigation is a video-based EPID, the BIS 710 (manufactured by Wellhöfer Dosimetrie, Schwarzenbruck, Germany). To examine the suitability of the BIS for CT at 6 MV beam quality, different phantoms were scanned and reconstructed. The agreement between a diamond detector and BIS responses is quantitative. Tomographic reconstruction of a complete set of these transmission profiles resulted in images which resolve 3 cm large objects having a (theoretical) contrast to water of less than 9%. Three millimetre objects with a 100% contrast are clearly visible. The BIS signal was shown to measure photon fluence distributions. The reconstructed images possess a spatial and contrast resolution sufficient for accurate imaging of the patient anatomy, needed for treatment verification in many clinical cases.

[1]  Grant T. Gullberg,et al.  Users Manual: Donner Algorithms for Reconstruction Tomography , 1977 .

[2]  E. A. Burgemeister Dosimetry with a diamond operating as a resistor. , 1981, Physics in medicine and biology.

[3]  W Swindell,et al.  A 4-MV CT scanner for radiation therapy: the prototype system. , 1982, Medical physics.

[4]  W Swindell,et al.  Computed tomography with a linear accelerator with radiotherapy applications. , 1983, Medical physics.

[5]  J. S. Laughlin,et al.  The Physics of Radiology. 4th ed , 1984 .

[6]  A Brahme,et al.  Radiotherapeutic computed tomography with scanned photon beams. , 1987, International journal of radiation oncology, biology, physics.

[7]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[8]  S Webb,et al.  A method to study the characteristics of 3D dose distributions created by superposition of many intensity-modulated beams delivered via a slit aperture with multiple absorbing vanes. , 1996, Physics in medicine and biology.

[9]  P M Evans,et al.  The application of transit dosimetry to precision radiotherapy. , 1996, Medical physics.

[10]  P M Evans,et al.  Extraction of primary signal from EPIDs using only forward convolution. , 1997, Medical physics.

[11]  M van Herk,et al.  Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  A L Boyer,et al.  Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system. , 1997, Medical physics.

[13]  J Dudson,et al.  A feasibility study for megavoltage cone beam CT using a commercial EPID. , 1998, Physics in medicine and biology.