On the possibilities to increase energy efficiency of domestic hot water preparation systems in existing buildings – Long term field research

Abstract Energy consumption for domestic hot water (DHW) preparation is one of the main components of the energy balance of the existing and newly designed buildings. However, based on the number of existing buildings and the related opportunities to improve energy efficiency, an important issue is to propose effective and low cost methods that allow to reduce the heat consumption in existing domestic hot water systems and are fast in the implementation. This article presents the results of an experimental research conducted in 12 objects (9 multifamily buildings and 3 thermal substations) assigned to three groups (A, B and C), depending on the analyzed feature of the domestic hot water system. The objects in the group A were analyzed in detail (each 1 h during one full heating season) in order to clearly show the amount of the heat used for circulation of hot water. The group B of objects characterized by the installation of temperature control valves (TCVs) under the risers of circulation installation. The third group consisted of the objects in which the temperature of hot water was decreased during the night hours. The objects from group B and C were analyzed over 8 years. The share of heat losses associated with the circulation of hot water in the total heat consumption supplied for its preparation was in the range from 56.7% to 70.5% for the Group A objects. On the other hand, the energy savings were calculated using different methodologies and for the recommended one they ranged from 8.5% to 49.5% for group B objects and from 6.0% to 14.4% for group C objects.

[1]  Daniel Słyś,et al.  Rationalization of water and energy consumption in shower systems of single-family dwelling houses , 2014 .

[2]  Svend Svendsen,et al.  Evaluations of different domestic hot water preparing methods with ultra-low-temperature district heating , 2016 .

[3]  Juan de Santiago,et al.  The generation of domestic hot water load profiles in Swiss residential buildings through statistical predictions , 2017 .

[4]  Rui Zhang,et al.  Experimental study on the performance of a gas engine heat pump for heating and domestic hot water , 2017 .

[5]  Igor Balen,et al.  On the influence of local and zonal hydraulic balancing of heating system on energy savings in existing buildings – Long term experimental research , 2018, Energy and Buildings.

[6]  Peng Guo,et al.  Comprehensive review on the development of SAHP for domestic hot water , 2017 .

[7]  R. Sekret,et al.  Effect of PCM application inside an evacuated tube collector on the thermal performance of a domestic hot water system , 2017 .

[8]  Jarek Kurnitski,et al.  Hourly consumption profiles of domestic hot water for different occupant groups in dwellings , 2016 .

[10]  L. M. López-González,et al.  Implementation of biomass boilers for heating and domestic hot water in multi-family buildings in Spain: Energy, environmental, and economic assessment , 2018 .

[11]  Alain Pascal Goumba,et al.  Air source heat pump for domestic hot water supply: Performance comparison between individual and building scale installations , 2018, Energy.

[12]  Constantinos A. Balaras,et al.  Modeling energy refurbishment scenarios for the Hellenic residential building stock towards the 2020 & 2030 targets , 2016 .

[13]  Weiqiang Kong,et al.  Thermal performance assessment and improvement of a solar domestic hot water tank with PCM in the mantle , 2018, Energy and Buildings.

[14]  François Maréchal,et al.  Characterisation of domestic hot water end-uses for integrated urban thermal energy assessment and optimisation , 2017 .

[15]  Svend Svendsen,et al.  Energy, economy and exergy evaluations of the solutions for supplying domestic hot water from low-temperature district heating in Denmark , 2016 .

[16]  Jarek Kurnitski,et al.  Monthly domestic hot water profiles for energy calculation in Finnish apartment buildings , 2015 .

[17]  V. Kapsalis,et al.  Cost/comfort-oriented optimization algorithm for operation scheduling of electric water heaters under dynamic pricing , 2018, Journal of Cleaner Production.

[18]  Benny Bøhm,et al.  Production and distribution of domestic hot water in selected Danish apartment buildings and institutions. Analysis of consumption, energy efficiency and the significance for energy design requirements of buildings , 2013 .

[19]  Ferdinando Salata,et al.  Heading towards the nZEB through CHP+HP systems. A comparison between retrofit solutions able to increase the energy performance for the heating and domestic hot water production in residential buildings , 2017 .

[20]  K. Sopian,et al.  Review of the application of phase change material for heating and domestic hot water systems , 2015 .

[21]  Luis Pérez-Lombard,et al.  A review on buildings energy consumption information , 2008 .

[22]  Jaume Salom,et al.  A review of domestic hot water consumption profiles for application in systems and buildings energy performance analysis , 2018 .

[23]  B. Head,et al.  Understanding Australian household water-related energy use and identifying physical and human characteristics of major end uses , 2016 .

[24]  M. Lightstone,et al.  Potential of cascaded phase change materials in enhancing the performance of solar domestic hot water systems , 2018 .

[25]  Nathaniel S. Pearre,et al.  High resolution measured domestic hot water consumption of Canadian homes , 2015 .

[26]  J. Jokisalo,et al.  Computational and experimental performance analysis of a novel method for heating of domestic hot water with a ground source heat pump system , 2018 .

[27]  Jarek Kurnitski,et al.  Analytical modelling and prediction formulas for domestic hot water consumption in residential Finnish apartments , 2017 .

[28]  Rui Yu,et al.  Survey and performance analysis of centralized domestic hot water system in China , 2016 .

[29]  P. Eames,et al.  Compact latent heat storage decarbonisation potential for domestic hot water and space heating applications in the UK , 2018 .

[30]  Xiaowei Fan,et al.  Experimental investigation on a heat pump water heater using R744/R290 mixture for domestic hot water , 2018, International Journal of Thermal Sciences.

[31]  S. Kenway,et al.  The effect of water demand management in showers on household energy use , 2017 .

[32]  Janusz Bujak,et al.  Heat consumption for preparing domestic hot water in hospitals , 2010 .

[33]  Francisco J. Aguilar,et al.  Experimental study of the solar photovoltaic contribution for the domestic hot water production with heat pumps in dwellings , 2016 .