Detection and quantification of proteins using self-excited PZT-glass millimeter-sized cantilever.

A composite self-excited PZT-glass cantilever (4mm in length and 2mm wide) was fabricated and used to measure the binding and unbinding of model proteins. A key feature of the cantilever is that its resonant frequency is dependent on its mass. The fabricated cantilever has mass change sensitivity in liquid of 7.2 x 10(-11)g/Hz. Resonant frequency change was measured as protein reacted or bound with the sensing glass cantilever surface. Protein concentrations, 0.1 and 1.0mg/mL, which resulted in nanogram mass change were successfully detected. The mass change sensitivity gave a total mass change of 54+/-0.45 ng for the binding of anti-rabbit IgG (biotin conjugated) to rabbit IgG immobilized cantilever and the subsequent binding of captavidin. The unbinding of anti-rabbit IgG and captavidin gave a total mass change of 54+/-1.70 ng. Fluorescence based assays showed the combined mass of both proteins in the released samples was 54+/-2.24 ng. The binding kinetics of the model proteins is modeled as first order. The initial binding rate constant of anti-rabbit IgG to rabbit IgG was 1.36+/-0.02(min(mg/mL))(-1). The initial binding rate constant of captavidin to biotinylated anti-rabbit IgG was (2.57 x 10(-1))+/-0.003(min(mg/mL))(-1). The significance of the results we report here is that millimeter-sized PZT-actuated glass cantilevers have the sensitivity to measure in real-time protein-protein binding, and the binding rate constant.

[1]  Mengsu Yang,et al.  Effect of hydrogel matrix on binding kinetics of protein–protein interactions on sensor surface , 2002 .

[2]  H W Hellinga,et al.  The rational design of allosteric interactions in a monomeric protein and its applications to the construction of biosensors. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[3]  G. Whitesides,et al.  Self-assembled organic monolayers: model systems for studying adsorption of proteins at surfaces , 1991, Science.

[4]  V. Hlady,et al.  Human Growth Hormone Adsorption Kinetics and Conformation on Self-Assembled Monolayers. , 1998, Langmuir : the ACS journal of surfaces and colloids.

[5]  Tae Song Kim,et al.  Label free novel electrical detection using micromachined PZT monolithic thin film cantilever for the detection of C-reactive protein. , 2004, Biosensors & bioelectronics.

[6]  M. Wilchek,et al.  Immobilized nitro-avidin and nitro-streptavidin as reusable affinity matrices for application in avidin-biotin technology. , 1996, Analytical biochemistry.

[7]  Song Zhang,et al.  Zeolite-modified microcantilever gas sensor for indoor air quality control , 2003 .

[8]  F. Elmer,et al.  Eigenfrequencies of a rectangular atomic force microscope cantilever in a medium , 1997 .

[9]  M. Miles,et al.  Chemical sensors and biosensors in liquid environment based on microcantilevers with amplified quality factor. , 2001, Ultramicroscopy.

[10]  T. Horbett,et al.  Proteins at interfaces : physicochemical and biochemical studies , 1987 .

[11]  O. H. Lowry,et al.  Protein measurement with the Folin phenol reagent. , 1951, The Journal of biological chemistry.

[12]  M. Grunze,et al.  Detection of non-specific protein adsorption at artificial surfaces by the use of acoustic plate mode sensors , 1996 .

[13]  T L Porter,et al.  Investigation of the antigen antibody reaction between anti-bovine serum albumin (a-BSA) and bovine serum albumin (BSA) using piezoresistive microcantilever based sensors. , 2003, Biosensors & bioelectronics.

[14]  T. Naik,et al.  Dynamic response of a cantilever in liquid near a solid wall , 2003 .

[15]  Hiroshi Sekiguchi,et al.  Intra- and intermolecular mechanics of proteins and polypeptides studied by AFM: with applications , 2002 .

[16]  M. Schönhoff,et al.  The influence of a viscous fluid on the vibration dynamics of scanning near-field optical microscopy fiber probes and atomic force microscopy cantilevers , 1998 .

[17]  W. Knoll,et al.  Supramolecular interfacial architectures for optical biosensing with surface plasmons , 2004 .

[18]  V. Hlady,et al.  Feasibility of measuring antigen-antibody interaction forces using a scanning force microscope. , 1999, Colloids and surfaces. B, Biointerfaces.

[19]  K. Yamanaka,et al.  Sharpening contact resonance spectra in UAFM using Q-control , 2003 .

[20]  Raj Mutharasan,et al.  In situ cell detection using piezoelectric lead zirconate titanate-stainless steel cantilevers , 2003 .

[21]  R. Brown,et al.  Protein measurement using bicinchoninic acid: elimination of interfering substances. , 1989, Analytical biochemistry.

[22]  Joyce Y. Wong,et al.  Surface probe measurements of the elasticity of sectioned tissue, thin gels and polyelectrolyte multilayer films : correlations between substrate stiffness and cell adhesion , 2004 .

[23]  Fei Liu,et al.  Flexoelectric origin of nanomechanic deflection in DNA-microcantilever system. , 2003, Biosensors & bioelectronics.

[24]  M. Wilchek,et al.  Reversibility of biotin-binding by selective modification of tyrosine in avidin. , 1996, The Biochemical journal.

[25]  Song Zhang,et al.  Self-excited piezoelectric microcantilever for gas detection , 2003 .

[26]  L. Lechuga,et al.  Development of nanomechanical biosensors for detection of the pesticide DDT. , 2003, Biosensors & bioelectronics.

[27]  Wan Y. Shih,et al.  Effect of length, width, and mode on the mass detection sensitivity of piezoelectric unimorph cantilevers , 2002 .

[28]  M. M. Bradford A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye binding. , 1976, Analytical biochemistry.

[29]  Raj Mutharasan,et al.  Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers. , 2005, Biosensors & bioelectronics.

[30]  R. A. McGill,et al.  Detection of 2,4-dinitrotoluene using microcantilever sensors , 2004 .

[31]  I. Aksay,et al.  Simultaneous liquid viscosity and density determination with piezoelectric unimorph cantilevers , 2001 .