Optimal structural design searching algorithm for cooling towers based on typical adverse wind load patterns

Abstract This investigation aims at typical adverse wind load patterns under tower group interference and overall structure optimization of large cooling towers considering multiple geometric parameters, focusing on potential unfavorable load patterns. Wind tunnel tests were performed on typical six-tower groups with various central distances, incoming flow directions and arrangement types, and external wind pressures were measured under interference conditions. Adverse wind load patterns are summarized with the help of interference criteria for three parameters: aerodynamic load, structure response and weighted internal force combination. Furthermore, overall structure optimization is achieved through the hybrid of grid search and gradient descent method, taking into account various possible wind loading distributions. Total 13 geometric parameters are adjusted to seek an optimized design that satisfy the requirement of structure strength, stability and economy under a particular wind load pattern. Crossover checks are then introduced to select a final optimized design scheme that is universally applicable to different adverse wind load patterns. The optimization procedure proposed in this study shows that adverse wind load patterns of grouped towers has distinct features comparing with wind load codes. It is necessary to consider the influence of multiple typical adverse wind load patterns for structural design, and the final optimization scheme should be determined through crossover checks to guarantee structure safety, stability and economy of cooling towers.

[1]  Hyuk-Chun Noh,et al.  Nonlinear behavior and ultimate load bearing capacity of reinforced concrete natural draught cooling tower shell , 2006 .

[2]  T. F. Sun,et al.  Full-scale measurement and wind-tunnel testing of wind loadings on two neighboring cooling towers , 1992 .

[3]  Ümit Uzman,et al.  Optimum shape design of shell structures , 2007 .

[4]  Jga Croll THE INFLUENCE OF SHAPE ON THE STRESSES IN COOLING TOWERS. , 1969 .

[5]  H.-J. Niemann,et al.  Influence of adjacent buildings on wind effects on cooling towers , 1998 .

[6]  Ihsan Mungan,et al.  Buckling of Stiffened Hyperboloidal Cooling Towers , 1979 .

[7]  Lin Zhao,et al.  Aerodynamic and aero-elastic performances of super-largecooling towers , 2014 .

[8]  Alphose Zingoni Structural health monitoring, damage detection and long-term performance , 2005 .

[9]  Luca Caracoglia,et al.  Simulation and analysis of intervention costs due to wind-induced damage on tall buildings , 2015 .

[10]  J. Form The ring-stiffened shell of the ISAR II nuclear power plant natural-draught cooling tower , 1986 .

[11]  Seymour M.J. Spence,et al.  Large scale reliability-based design optimization of wind excited tall buildings , 2012 .

[12]  Wei Cui,et al.  Wind-resistant design and safety evaluation of cooling towers by reinforcement area criterion , 2019, Engineering Structures.

[13]  C. S. Manohar,et al.  An improved response surface method for the determination of failure probability and importance measures , 2004 .

[14]  Hans-Jürgen Niemann,et al.  Full-scale and model tests on wind-induced, static and dynamic stresses in cooling tower shells , 1980 .

[15]  T. F. Sun,et al.  Wind pressure distribution around a ribless hyperbolic cooling tower , 1983 .

[16]  Min-Jea Tahk,et al.  A hybrid optimization method of evolutionary and gradient search , 2007 .

[17]  Hans-Jürgen Niemann,et al.  Some properties of fluctuating wind pressures on a full-scale cooling tower☆ , 1975 .

[18]  Reinhard Harte,et al.  New natural draft cooling tower of 200 m of height , 2002 .

[19]  Y. Ge,et al.  Fluctuating wind pressure distribution around full-scale cooling towers , 2017 .

[20]  Hans-Jürgen Niemann,et al.  Impact of research on development of large cooling towers , 1986 .

[21]  R. R. McLone Effect of loading on cooling towers of three different shapes , 1963 .

[22]  R A Pope,et al.  STRUCTURAL DEFICIENCIES OF NATURAL DRAUGHT COOLING TOWERS AT UK POWER STATIONS. PART 1: FAILURES AT FERRYBRIDGE AND FIDDLERS FERRY. , 1994 .

[23]  Jingwei Zheng,et al.  Investigation of Natural Draft Cooling Tower in China , 2017 .

[24]  David P. Billington,et al.  Wind Loading and Response of Cooling Towers , 1980 .

[25]  Mehdi H. K. Kharrazi,et al.  EFFECT OF STIFFENING RINGS ON BUCKLING STABILITY OF R.C. HYPERBOLIC COOLING TOWERS , 2006 .

[26]  Reinhard Harte,et al.  Large-scale cooling towers as part of an efficient and cleaner energy generating technology , 2002 .

[27]  Luca Caracoglia,et al.  A unified framework for performance-based wind engineering of tall buildings in hurricane-prone regions based on lifetime intervention-cost estimation , 2018, Structural Safety.

[28]  Yi Li,et al.  Wind-induced response based optimal design of irregular shaped tall buildings , 2016 .

[29]  Nikos D. Lagaros,et al.  Optimum design of shell structures with random geometric, material and thickness imperfections , 2006 .

[30]  Y. Ge,et al.  Wind-induced equivalent static interference criteria and its effects on cooling towers with complex arrangements , 2018, Engineering Structures.

[31]  Alphose Zingoni,et al.  Damage, deterioration and the long-term structural performance of cooling-tower shells: A survey of developments over the past 50 years , 2005 .

[32]  Hans-Jurgen Niemann Wind Effects on Cooling-Tower Shells , 1980 .

[33]  Lin Zhao,et al.  Investigations of adverse wind loads on a large cooling tower for the six-tower combination , 2016 .