High-performance liquid chromatographic cartridge with gradient elution capability coupled with UV absorbance detector and mass spectrometer for peptide and protein analysis.

We discuss the construction and performance of a high-performance liquid chromatography cartridge that we developed that resulted from a culmination of previous research. We have recently developed an innovative approach to creating gradient elutions using dual electroosmotic pumps and a series of three valves. This method has been proved to be the most reproducible and robust in producing gradients compared to our previously tested methods. Using this approach, we have assembled a high-performance liquid chromatography cartridge powered and controlled via a computer. We have successfully coupled the cartridge with an ultraviolet absorbance detector and a mass spectrometer for separating complex protein/peptide samples. The cartridge is readily coupled with other detectors such as electrochemical detector and laser-induced fluorescence detector.

[1]  M. Zhang,et al.  Monitoring gradient profile on-line in micro- and nano-high performance liquid chromatography using conductivity detection. , 2016, Journal of chromatography. A.

[2]  Q. Fang,et al.  A handheld laser-induced fluorescence detector for multiple applications. , 2016, Talanta.

[3]  Jozef Šesták,et al.  Instrument platforms for nano liquid chromatography. , 2015, Journal of chromatography. A.

[4]  H. Tolley,et al.  Hand-portable liquid chromatographic instrumentation. , 2015, Journal of chromatography. A.

[5]  M. S. Franco,et al.  Evolution in miniaturized column liquid chromatography instrumentation and applications: An overview. , 2015, Journal of chromatography. A.

[6]  H. Tolley,et al.  Hand-Portable Gradient Capillary Liquid Chromatography Pumping System. , 2015, Analytical chemistry.

[7]  M. Zhang,et al.  Combining selection valve and mixing chamber for nanoflow gradient generation: Toward developing a liquid chromatography cartridge coupled with mass spectrometer for protein and peptide analysis. , 2015, Analytica Chimica Acta.

[8]  H. Tolley,et al.  LED-based UV absorption detector with low detection limits for capillary liquid chromatography. , 2015, Analytical chemistry.

[9]  P. Aggarwal,et al.  High efficiency polyethylene glycol diacrylate monoliths for reversed-phase capillary liquid chromatography of small molecules. , 2014, Journal of chromatography. A.

[10]  Shaorong Liu,et al.  Incorporating high-pressure electroosmotic pump and a nano-flow gradient generator into a miniaturized liquid chromatographic system for peptide analysis. , 2014, Analytica chimica acta.

[11]  P. B. Farnsworth,et al.  Instrumentation for hand-portable liquid chromatography. , 2014, Journal of chromatography. A.

[12]  S. Shiva Nitrite: A physiological store of nitric oxide and modulator of mitochondrial function☆ , 2013, Redox biology.

[13]  Shaorong Liu,et al.  Miniaturized electroosmotic pump capable of generating pressures of more than 1200 bar. , 2012, Analytical chemistry.

[14]  Shaorong Liu,et al.  Stacking open-capillary electroosmotic pumps in series to boost the pumping pressure to drive high-performance liquid chromatographic separations. , 2012, Journal of chromatography. A.

[15]  R. Mathies,et al.  Design and operation of a portable scanner for high performance microchip capillary array electrophoresis. , 2010, The Review of scientific instruments.

[16]  U. Flögel,et al.  Unmasking the Janus face of myoglobin in health and disease , 2010, Journal of Experimental Biology.

[17]  G. B. Richter‐Addo,et al.  The distal pocket histidine residue in horse heart myoglobin directs the O-binding mode of nitrite to the heme iron. , 2009, Journal of the American Chemical Society.

[18]  M. Marina,et al.  Application of micro- and nano-HPLC to the determination and characterization of bioactive and biomarker peptides. , 2008, Journal of separation science.

[19]  J. Moult,et al.  Loss of protein structure stability as a major causative factor in monogenic disease. , 2005, Journal of molecular biology.

[20]  M. Smith,et al.  Expression in Escherichia coli of a synthetic gene coding for horse heart myoglobin. , 1991, Protein engineering.

[21]  J. Stetter,et al.  Portable liquid chromatograph for analysis of primary aromatic amines in coal-derived materials , 1986 .