Numerical and experimental validation of a single-camera 3D velocimetry based on endoscopic tomography.

Tomographic velocimetry as a 3D technique has attracted substantial research interests in recent years due to the pressing need for investigations of complex turbulent flows, which are inherently inhomogeneous. However, tomographic velocimetry usually suffers from high experimental costs, especially due to the formidable expenses of multiple high-speed cameras and the excitation laser source. To overcome this limitation, a cost-effective technique called endoscopic tomographic velocimetry has been developed in this work. As a single-camera system, nine projections of the target 3D luminous field at consecutive time instants can be registered from different orientations with one camera and customized fiber bundles, while this is possible only with the same number of cameras in a classical tomographic velocimetry system. Extensive numerical simulations were conducted with three inversion algorithms and two velocity calculation methods. According to RMS error analysis, it was found that the algebraic reconstruction technique outperformed the other two inversion algorithms, and the 3D optical flow method exhibited a better performance than cross correlation in terms of both accuracy and noise immunity. Proof-of-concept experiments were also performed to validate our developed system. The results suggested that an average reconstruction error of the artificially generated 3D velocity field was less than 6%, indicating good performance of the velocimetry system. Although this technique was demonstrated by reconstructing continuous luminous fields, it can be easily extended to discrete ones, which are typically adopted in particle image velocimetry. This technique is promising not only for flow diagnostics but other research areas such as biomedical imaging.

[1]  Jinjun Wang,et al.  Intensity-enhanced MART for tomographic PIV , 2016 .

[2]  Wolfgang Schröder,et al.  Scanning PIV measurements of a laminar separation bubble , 2006 .

[3]  Markus Kowarschik,et al.  GPU-accelerated SART reconstruction using the CUDA programming environment , 2009, Medical Imaging.

[4]  Naibo Jiang,et al.  4D spatiotemporal evolution of combustion intermediates in turbulent flames using burst-mode volumetric laser-induced fluorescence. , 2017, Optics letters.

[5]  J. Gord,et al.  Two-color volumetric laser-induced fluorescence for 3D OH and temperature fields in turbulent reacting flows. , 2018, Optics letters.

[6]  Xuesong Li,et al.  Practical aspects of implementing three-dimensional tomography inversion for volumetric flame imaging. , 2013, Applied optics.

[7]  W. Hentschel,et al.  Endoscopic 2D particle image velocimetry (PIV) flow field measurements in IC engines , 2002 .

[8]  A. Kempf,et al.  Computed Tomography of Chemiluminescence (CTC): Instantaneous 3D measurements and Phantom studies of a turbulent opposed jet flame , 2011 .

[9]  Tao Yu,et al.  Benchmark evaluation of inversion algorithms for tomographic absorption spectroscopy. , 2017, Applied optics.

[10]  Javier Sánchez Pérez,et al.  TV-L1 Optical Flow Estimation , 2013, Image Process. Line.

[11]  Kyle J. Daun,et al.  Chemical species tomography of turbulent flows: Discrete ill-posed and rank deficient problems and the use of prior information , 2016 .

[12]  Manoochehr Koochesfahani,et al.  A spatial correlation technique for estimating velocity fields using molecular tagging velocimetry (MTV) , 1996 .

[13]  P. Gilbert Iterative methods for the three-dimensional reconstruction of an object from projections. , 1972, Journal of theoretical biology.

[14]  Themistocles Dracos,et al.  Time resolved 3D passive scalar concentration-field imaging by laser induced fluorescence (LIF) in moving liquids , 2001 .

[15]  S A Tsekenis,et al.  Spatially resolved and observer-free experimental quantification of spatial resolution in tomographic images. , 2015, The Review of scientific instruments.

[16]  James R. Gord,et al.  20-kHz-rate three-dimensional tomographic imaging of the concentration field in a turbulent jet , 2017 .

[17]  Hecong Liu,et al.  Demonstration of 3D computed tomography of chemiluminescence with a restricted field of view. , 2017, Applied optics.

[18]  Qi Gao,et al.  Review on development of volumetric particle image velocimetry , 2013 .

[19]  G. Herman,et al.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. , 1970, Journal of theoretical biology.

[20]  Fulvio Scarano,et al.  Tomographic PIV: principles and practice , 2012 .

[21]  Fulvio Scarano,et al.  An efficient and accurate approach to MTE-MART for time-resolved tomographic PIV , 2015 .

[22]  Lin Ma,et al.  Capabilities and limitations of 3D flame measurements based on computed tomography of chemiluminescence , 2015 .

[23]  Kees Joost Batenburg,et al.  Motion tracking-enhanced MART for tomographic PIV , 2010 .

[24]  Javier Sánchez Pérez,et al.  Horn-Schunck Optical Flow with a Multi-Scale Strategy , 2013, Image Process. Line.

[25]  A lattice Boltzmann method for simulating laser cutting of thin metal plates , 2017 .

[26]  Andreas Kempf,et al.  Computed Tomography of Chemiluminescence (CTC): High resolution and instantaneous 3-D measurements of a Matrix burner , 2011 .

[27]  Fei Li,et al.  Uncertainty in velocity measurement based on diode-laser absorption in nonuniform flows. , 2012, Applied optics.

[28]  Bernhard Wieneke,et al.  Tomographic particle image velocimetry , 2006 .

[29]  R. Adrian,et al.  Whole field measurement of temperature in water using two-color laser induced fluorescence , 1997 .

[30]  Fei Li,et al.  Numerical and experimental validation of a three-dimensional combustion diagnostic based on tomographic chemiluminescence. , 2013, Optics express.

[31]  Dianne P. O'Leary,et al.  The Use of the L-Curve in the Regularization of Discrete Ill-Posed Problems , 1993, SIAM J. Sci. Comput..

[32]  I. Grant Particle image velocimetry: A review , 1997 .

[33]  C. Brücker 3D scanning PIV applied to an air flow in a motored engine using digital high-speed video , 1997 .

[34]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[35]  James R. Gord,et al.  kHz-rate four-dimensional fluorescence tomography using an ultraviolet-tunable narrowband burst-mode optical parametric oscillator , 2017 .

[36]  Tianshu Liu,et al.  Comparison between optical flow and cross-correlation methods for extraction of velocity fields from particle images , 2015 .

[37]  D Verhoeven,et al.  Limited-data computed tomography algorithms for the physical sciences. , 1993, Applied optics.