Diffusion tensor imaging of mouse brain stem and cervical spinal cord

In vivo diffusion tensor imaging measurements of the mouse brain stem and cervical spinal cord are presented. Utilizing actively decoupled transmit/receive coils, high resolution diffusion images (117 microm x 59 microm x 500 microm) were acquired at 4.7 T within an hour. Both brain stem and cervical spine displayed clear gray-white matter contrast. The cervical spinal cord white matter showed similar tissue characteristics as seen in the thoracic cord. The coherent fiber orientation in the white matter was observed in both the brain stem and the cervical spinal cord. The results may serve as a reference for future inter-lab comparison in mouse brain stem and cervical spine diffusion measurements.

[1]  S Pajevic,et al.  Color schemes to represent the orientation of anisotropic tissues from diffusion tensor data: Application to white matter fiber tract mapping in the human brain , 1999, Magnetic resonance in medicine.

[2]  R. E. Schmidt,et al.  Noninvasive diffusion tensor imaging of evolving white matter pathology in a mouse model of acute spinal cord injury , 2007, Magnetic resonance in medicine.

[3]  K. Hasan,et al.  Diffusion tensor imaging of in vivo and excised rat spinal cord at 7 T with an icosahedral encoding scheme , 2005, Magnetic resonance in medicine.

[4]  Paul M. Mellor,et al.  Active coil isolation in NMR imaging and spectroscopy using PIN diodes and tuned transmission line: a practical approach , 2006, Magnetic Resonance Materials in Physics, Biology and Medicine.

[5]  J. Hrabe,et al.  Interleaved snapshot echo planar imaging of mouse brain at 7.0 T , 2006, NMR in biomedicine.

[6]  R. Guiloff,et al.  Widespread loss of neuronal populations in the spinal ventral horn in sporadic motor neuron disease. A morphometric study , 2006, Journal of the Neurological Sciences.

[7]  H. Scheich,et al.  In vivo quantification of spinal and bulbar motor neuron degeneration in the G93A-SOD1 transgenic mouse model of ALS by T 2 relaxation time and apparent diffusion coefficient , 2006, Experimental Neurology.

[8]  M. Bastin,et al.  A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging. , 1998, Magnetic resonance imaging.

[9]  Hsiao-Fang Liang,et al.  Detecting axon damage in spinal cord from a mouse model of multiple sclerosis , 2006, Neurobiology of Disease.

[10]  Abbas F Jawad,et al.  MRI diffusion coefficients in spinal cord correlate with axon morphometry , 2005, Neuroreport.

[11]  Thomas L Chenevert,et al.  Clinical applications of diffusion tensor imaging , 2004, Journal of magnetic resonance imaging : JMRI.

[12]  L. Bruijn,et al.  Unraveling the mechanisms involved in motor neuron degeneration in ALS. , 2004, Annual review of neuroscience.

[13]  M. Bilgen,et al.  Magnetic resonance imaging of mouse spinal cord , 2005, Magnetic resonance in medicine.

[14]  P. Basser,et al.  A unifying theoretical and algorithmic framework for least squares methods of estimation in diffusion tensor imaging. , 2006, Journal of magnetic resonance.

[15]  D. Le Bihan,et al.  Diffusion tensor imaging: Concepts and applications , 2001, Journal of magnetic resonance imaging : JMRI.

[16]  C. Ferris,et al.  A dual RF resonator system for high-field functional magnetic resonance imaging of small animals , 2004, Journal of Neuroscience Methods.

[17]  P. Basser,et al.  Toward a quantitative assessment of diffusion anisotropy , 1996, Magnetic resonance in medicine.

[18]  I. Maričić,et al.  Mini Review: Immune Response to Myelin-Derived Sulfatide and CNS-Demyelination , 2007, Neurochemical Research.

[19]  C. Raine,et al.  Chronologic localization of myelin‐reactive cells in the lesions of relapsing EAE , 1993, Neurology.

[20]  Kathryn Trinkaus,et al.  Postmortem delay does not change regional diffusion anisotropy characteristics in mouse spinal cord white matter , 2007, NMR in biomedicine.

[21]  E. D. Schwartz,et al.  In vivo DTI evaluation of white matter tracts in rat spinal cord , 2006, Journal of magnetic resonance imaging : JMRI.

[22]  Magnetic resonance microscopy of spinal cord injury in mouse using a miniaturized implantable RF coil , 2007, Journal of Neuroscience Methods.

[23]  F. Franconi,et al.  In vivo quantitative microimaging of rat spinal cord at 7T , 2000, Magnetic resonance in medicine.

[24]  P. Cozzone,et al.  In vivo mouse spinal cord imaging using echo-planar imaging at 11.75 T , 2007, Magnetic Resonance Materials in Physics, Biology and Medicine.

[25]  K Ugurbil,et al.  Detunable transverse electromagnetic (TEM) volume coil for high‐field NMR , 2002, Magnetic resonance in medicine.

[26]  Andre D. A. Souza,et al.  Indirect measurement of regional axon diameter in excised mouse spinal cord with q-space imaging: Simulation and experimental studies , 2008, NeuroImage.

[27]  A. Anderson Theoretical analysis of the effects of noise on diffusion tensor imaging , 2001, Magnetic resonance in medicine.

[28]  J. Bonny,et al.  Nuclear magnetic resonance microimaging of mouse spinal cord in vivo , 2004, Neurobiology of Disease.

[29]  Katherine J Lobur,et al.  Pbx3 is required for normal locomotion and dorsal horn development. , 2008, Developmental biology.

[30]  M. Bilgen In vivo corticospinal tract tracing in mouse using manganese-enhanced contrast , 2007 .

[31]  B. Ellingson,et al.  In vivo diffusion tensor imaging of the rat spinal cord at 9.4T , 2008, Journal of magnetic resonance imaging : JMRI.

[32]  J. E. Tanner,et al.  Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient , 1965 .

[33]  Ravi S. Menon,et al.  A transmit‐only/receive‐only (TORO) RF system for high‐field MRI/MRS applications , 2000, Magnetic resonance in medicine.