Test-Based Calibration of Safety Factors for Capacity Models

AbstractA simple procedure to calibrate the safety factor of capacity models is presented. The calibration can be carried out based on any available database of experimental tests, even of limited size. The procedure aims to assess the model capability of predicting the test results and to calibrate the safety factor so that the capacity equation meets the target reliability level required by the code or sought by the calibrator. After predicting each test of the database with the capacity equation under consideration, the test-prediction pairs are checked for the property of linearity, and the relative error for the properties of homoscedasticity and normality. Once these properties are fulfilled—which may require a nonlinear transformation of the test values and/or the predictions—the closed-form equation proposed in this paper is employed to compute a target design value. The model safety factor is finally obtained by comparing such target design value with the design value obtained from the code. The ...