Modeling Approach for An Aortic Dissection with Endovascular Stenting*

Repair of dissected aorta requires remodeling the structure of the media. Modeling approaches specific to endovascular stenting for aortic dissection have been reported. We created a goat model of descending thoracic aortic dissection and reproduced its morphological characteristics in a mock circulatory system. The purpose of this study was to examine a newly developed aortic stent which was capable of installing to the aortic dissected lesion for biomedical hemodynamics point of view. In this study, we examined the changes in hemodynamics of dissected lesions and the amelioration by endovascular stent intervention. Firstly, we performed animal experiments with the dissected aorta and examined the effects of stenting on volumetric changes in the false lumen. Secondly, we made several types of 3-D stereolithographic dissected aortic models with silicone rubber membrane between the false and the true lumens. Then, the hemodynamic characteristics in each model were evaluated in the pulsatile flow conditions in a mock circulatory system. These modelling approaches enabled the quantitative examination of post-therapeutic effects of stenting followed by elucidating of hemodynamic changes in the vicinity of stents, which may follow the management of clinical amelioration of interventional treatment with aortic stenting.Clinical Relevance— This study represents a modelling approach of the dissected aorta for endovascular intervention using stenting followed by the examination of false lumen volumetric changes resulting in the deterioration of pressure increase in diseased lesions.

[1]  Victor H Barocas,et al.  Ex Vivo Mechanical Tests and Multiscale Computational Modeling Highlight the Importance of Intramural Shear Stress in Ascending Thoracic Aortic Aneurysms. , 2019, Journal of biomechanical engineering.

[2]  Athanasios Katsargyris,et al.  Techniques and outcomes of secondary endovascular repair for postdissection TAA/TAAA. , 2018, The Journal of cardiovascular surgery.

[3]  Kazuhiko Hanzawa,et al.  Surgical Treatment for Kommerell’s Diverticulum Associated with a Right-Sided Aortic Arch and an Aberrant Left Subclavian Artery: Endovascular or Hybrid , 2019, Annals of vascular diseases.

[4]  Raffaele Giordano,et al.  Treatment with transfemoral bare-metal stent of residual aortic arch dissection after surgical repair of acute type an aortic dissection. , 2018, Journal of thoracic disease.

[5]  Mitsuaki Sadahiro,et al.  Thoracic Endovascular Aortic Repair for Acute Aortic Dissection , 2018, Annals of vascular diseases.

[6]  Andrew D Althouse,et al.  Bare Metal Stent Use in Type B Aortic Dissection May Offer Positive Remodeling for the Distal Aorta. , 2018, The Annals of thoracic surgery.

[7]  D J Bouchier-Hayes,et al.  Is compliance mismatch the major cause of anastomotic arterial aneurysms? Analysis of 42 cases. , 1985, The Journal of cardiovascular surgery.

[8]  C. Marty-ané,et al.  Human ex-vivo model of Stanford type B aortic dissection. , 2014, Journal of vascular surgery.

[9]  J. Appoo,et al.  Early Results of the PETTICOAT Technique for the Management of Acute Type A Aortic Dissection , 2017, AORTA.

[10]  Yoshikatsu Saiki,et al.  Medial Regeneration Using a Biodegradable Felt as a Scaffold Preserves Integrity and Compliance of a Canine Dissected Aorta , 2011, Circulation.